Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 24(3): 2542-61, 2016 Feb 08.
Article in English | MEDLINE | ID: mdl-26906828

ABSTRACT

This paper describes the development and application of a novel optical technique for the measurement of liquid film thickness formed on surfaces during the impingement of automotive fuel sprays. The technique makes use of the change of the light scattering characteristics of a metal surface with known roughness, when liquid is deposited. Important advantages of the technique over previously established methods are the ability to measure the time-dependent spatial distribution of the liquid film without a need to add a fluorescent tracer to the liquid, while the measurement principle is not influenced by changes of the pressure and temperature of the liquid or the surrounding gas phase. Also, there is no need for non-fluorescing surrogate fuels. However, an in situ calibration of the dependence of signal intensity on liquid film thickness is required. The developed method can be applied to measure the time-dependent and two-dimensional distribution of the liquid fuel film thickness on the piston or the liner of gasoline direct injection (GDI) engines. The applicability of this technique was evaluated with impinging sprays of several linear alkanes and alcohols with different thermo-physical properties. The surface temperature of the impingement plate was controlled to simulate the range of piston surface temperatures inside a GDI engine. Two sets of liquid film thickness measurements were obtained. During the first set, the surface temperature of the plate was kept constant, while the spray of different fuels interacted with the surface. In the second set, the plate temperature was adjusted to match the boiling temperature of each fuel. In this way, the influence of the surface temperature on the liquid film created by the spray of different fuels and their evaporation characteristics could be demonstrated.

2.
J Mech Behav Biomed Mater ; 30: 50-60, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24231189

ABSTRACT

Percutaneous needle insertions are a common part of minimally invasive surgery. However, the insertion process is necessarily disruptive to the substrate. Negative side effects are migration of deep-seated targets and trauma to the surrounding material. Mitigation of these effects is highly desirable, but relies on a detailed understanding of the needle-tissue interactions, which are difficult to capture at a sufficiently high resolution. Here, an adapted Digital Image Correlation (DIC) technique is used to quantify mechanical behaviour at the sliding interface, with resolution of measurement points which is better than 0.5mm, representing a marked improvement over the state of the art. A method for converting the Eulerian description of DIC output to Lagrangian displacements and strains is presented and the method is validated during the simple insertion of a symmetrical needle into a gelatine tissue phantom. The needle is comprised of four axially interlocked quadrants, each with a bevel tip. Tests are performed where the segments are inserted into the phantom simultaneously, or in a cyclic sequence taking inspiration from the unique insertion strategy associated to the ovipositor of certain wasps. Data from around the needle-tissue interface includes local strain variations, material dragged along the needle surface and relaxation of the phantom, which show that the cyclic actuation of individual needle segments is potentially able to mitigate tissue strain and could be used to reduce target migration.


Subject(s)
Biomimetics/instrumentation , Needles , Equipment Design , Gelatin , Image Processing, Computer-Assisted , Motion , Phantoms, Imaging , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...