Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
J Prosthet Dent ; 118(1): 83-88, 2017 Jul.
Article in English | MEDLINE | ID: mdl-27927286

ABSTRACT

STATEMENT OF PROBLEM: The marginal adaptation of prosthetic crowns is still a significant clinical problem. PURPOSE: The purpose of this in vitro study was to evaluate the marginal deficiency and misfit of Ni-Cr alloys with and without beryllium under different casting conditions. MATERIAL AND METHODS: Four casting conditions were selected: flame-torch, induction/argon, induction/vacuum, and induction/air; and 2 alloys were used, Ni-Cr-Be and Ni-Cr. For each group, 10 metal specimens were prepared. Silicone indirect impressions and analysis of the degree of rounding were used to evaluate the marginal deficiencies of metal copings, and a standardized device for the setting pressure associated with optical microscopy was used to analyze the marginal misfit. Results were evaluated with 2-way ANOVA (α=.05), followed by the Tukey honest significant difference post hoc test, and the Pearson correlation test (α=.05). RESULTS: Alloy (P<.001) and casting technique (P<.001) were shown to affect marginal deficiencies. The Ni-Cr cast using the torch technique showed the highest marginal deficiency, and the Ni-Cr-Be cast in a controlled argon atmosphere showed the lowest (P<.001). Alloy (P=.472) and casting techniques (P=.206) did not affect the marginal misfit, but significant differences were found in the interaction (P=.001); the lowest misfit was achieved using the Ni-Cr-Be, and the highest misfit occurred with the molten Ni-Cr, using the cast torch technique. No correlation was found between deficiency and marginal misfit (r=.04, P=.69). CONCLUSIONS: The interactions demonstrated that the alloy containing beryllium that was cast in an argon atmosphere led to reduced marginal deficiency. Improved marginal adaptation can be achieved for the same alloy by using the torch technique.


Subject(s)
Beryllium/chemistry , Chromium Alloys/chemistry , Dental Casting Investment/chemistry , Dental Casting Technique , Dental Marginal Adaptation , Argon , Atmosphere , Crowns , Dental Casting Technique/instrumentation , Dental Impression Materials , Dental Materials/chemistry , Dental Prosthesis Design , Materials Testing , Metal Ceramic Alloys , Microscopy , Nickel , Pressure , Silicone Elastomers/chemistry , Surface Properties , Vacuum
2.
Microsc Res Tech ; 78(12): 1098-103, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26497153

ABSTRACT

The aim of this study was to evaluate radiographically and histologically the pulpal and periapical response to self-adhesive (Rely X™ Unicem) and self-etching and self-curing (Multilink(®)) resin-based luting materials in deep cavities in dogs' teeth. Deep class V cavities (0.5-mm-thick dentin) were prepared in 60 canine premolars and the following materials were applied on cavity floor: Groups I/V-RelyX™ Unicem; Groups II/VI-Multilink(®); Groups III/VII-zinc phosphate cement (control) and; Groups IV/VIII-gutta-percha (control). Cavities were restored with silver amalgam. Animals were euthanized after 10 days (groups I-IV) and 90 days (groups V-VIII). Tooth/bone blocks were radiographed and processed for histopathological evaluation of pulp and periapical tissue response to the materials. All materials presented similar histopathological features and radiographic findings at both periods. The pulp tissue was intact. The apical and periapical regions and periodontal ligament thickness were normal. No inflammatory cells, resorption of mineralized tissue (dentin, cementum, and alveolar bone) or bacteria were observed. The lamina dura was intact and no areas of periapical bone rarefaction or internal/external root resorption were observed radiographically. It can be concluded that Rely X™ Unicem and Multilink(®) caused no adverse tissue reactions and may be indicated for cementation of indirect restorations in deep dentin cavities without pulp exposure.


Subject(s)
Bicuspid/diagnostic imaging , Dental Caries/pathology , Dental Cavity Preparation , Dental Cements/adverse effects , Resins, Synthetic/administration & dosage , Resins, Synthetic/adverse effects , Animals , Dogs , Radiography
3.
Dent Mater ; 29(7): 788-96, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23694844

ABSTRACT

OBJECTIVES: A validated numerical model for stress/strain predictions is essential in understanding the biomechanical behavior of implant-supported dental prostheses. The digital image correlation (DIC) method for full-field strain measurement was compared with finite element analysis (FEA) in assessing bone strain induced by implants. METHODS: An epoxy resin model simulating the lower arch was made for the experimental test with acrylic resin replicas of the first premolar and second molar and threaded implants replacing the second premolar and first molar. Splinted (G1/G3) and non-splinted (G2/G4) metal-ceramic screw-retained crowns were fabricated and loaded with (G1/G2) or without (G3/G4) the second molar that provided proximal contact. A single-camera, two-dimensional DIC system was used to record deformation of the resin model surface under a load of 250N. Three-dimensional finite element (FE) models were constructed for the physical models using computer-aided design (CAD) software. Surface strains were used for comparison between the two methods, while internal strains at the implant/resin block interface were calculated using FEA. RESULTS: Both methods found similar strain distributions over the simulant bone block surface, which indicated possible benefits of having splinted crowns and proximal contact in reducing bone strains. Internal strains predicted by FEA at the implant-resin interface were 8 times higher than those on the surface of the model, and they confirmed the results deduced from the surface strains. FEA gave higher strain values than experiments, probably due to incorrect material properties being used. SIGNIFICANCE: DIC is a useful tool for validating FE models used for the biomechanical analysis of dental prosthesis.


Subject(s)
Dental Prosthesis, Implant-Supported , Dental Stress Analysis/methods , Finite Element Analysis , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Numerical Analysis, Computer-Assisted , Analysis of Variance , Biomechanical Phenomena , Compressive Strength , Dental Implants , Elastic Modulus , Humans , Statistics, Nonparametric
4.
J Appl Oral Sci ; 19(5): 483-7, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21986653

ABSTRACT

OBJECTIVE: Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD. MATERIAL AND METHODS: Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5% significance level. RESULTS: Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI. CONCLUSIONS: It may be concluded that 0.05% NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.


Subject(s)
Chromium Alloys/pharmacokinetics , Denture Cleansers/pharmacology , Denture, Partial, Removable , Analysis of Variance , Biofilms/drug effects , Immersion , Ions/pharmacokinetics , Mass Spectrometry , Materials Testing , Surface Properties , Time Factors
5.
J. appl. oral sci ; 19(5): 483-487, Sept.-Oct. 2011. ilus, tab
Article in English | LILACS | ID: lil-600849

ABSTRACT

OBJECTIVE: Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD. MATERIAL AND METHODS: Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05 percent sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5 percent significance level. RESULTS: Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI. CONCLUSIONS: It may be concluded that 0.05 percent NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.


Subject(s)
Chromium Alloys/pharmacokinetics , Denture, Partial, Removable , Denture Cleansers/pharmacology , Analysis of Variance , Biofilms/drug effects , Immersion , Ions/pharmacokinetics , Mass Spectrometry , Materials Testing , Surface Properties , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...