1.
J Biomed Inform ; 147: 104522, 2023 11.
Article in English | MEDLINE | ID: mdl-37827476

ABSTRACT

OBJECTIVE: Audit logs in electronic health record (EHR) systems capture interactions of providers with clinical data. We determine if machine learning (ML) models trained using audit logs in conjunction with clinical data ("observational supervision") outperform ML models trained using clinical data alone in clinical outcome prediction tasks, and whether they are more robust to temporal distribution shifts in the data. MATERIALS AND METHODS: Using clinical and audit log data from Stanford Healthcare, we trained and evaluated various ML models including logistic regression, support vector machine (SVM) classifiers, neural networks, random forests, and gradient boosted machines (GBMs) on clinical EHR data, with and without audit logs for two clinical outcome prediction tasks: major adverse kidney events within 120 days of ICU admission (MAKE-120) in acute kidney injury (AKI) patients and 30-day readmission in acute stroke patients. We further tested the best performing models using patient data acquired during different time-intervals to evaluate the impact of temporal distribution shifts on model performance. RESULTS: Performance generally improved for all models when trained with clinical EHR data and audit log data compared with those trained with only clinical EHR data, with GBMs tending to have the overall best performance. GBMs trained with clinical EHR data and audit logs outperformed GBMs trained without audit logs in both clinical outcome prediction tasks: AUROC 0.88 (95% CI: 0.85-0.91) vs. 0.79 (95% CI: 0.77-0.81), respectively, for MAKE-120 prediction in AKI patients, and AUROC 0.74 (95% CI: 0.71-0.77) vs. 0.63 (95% CI: 0.62-0.64), respectively, for 30-day readmission prediction in acute stroke patients. The performance of GBM models trained using audit log and clinical data degraded less in later time-intervals than models trained using only clinical data. CONCLUSION: Observational supervision with audit logs improved the performance of ML models trained to predict important clinical outcomes in patients with AKI and acute stroke, and improved robustness to temporal distribution shifts.


Subject(s)
Acute Kidney Injury , Stroke , Humans , Electronic Health Records , Hospitalization , Prognosis
2.
Bioengineering (Basel) ; 10(2)2023 Feb 04.
Article in English | MEDLINE | ID: mdl-36829701

ABSTRACT

We systematically evaluate the training methodology and efficacy of two inpainting-based pretext tasks of context prediction and context restoration for medical image segmentation using self-supervised learning (SSL). Multiple versions of self-supervised U-Net models were trained to segment MRI and CT datasets, each using a different combination of design choices and pretext tasks to determine the effect of these design choices on segmentation performance. The optimal design choices were used to train SSL models that were then compared with baseline supervised models for computing clinically-relevant metrics in label-limited scenarios. We observed that SSL pretraining with context restoration using 32 × 32 patches and Poission-disc sampling, transferring only the pretrained encoder weights, and fine-tuning immediately with an initial learning rate of 1 × 10-3 provided the most benefit over supervised learning for MRI and CT tissue segmentation accuracy (p < 0.001). For both datasets and most label-limited scenarios, scaling the size of unlabeled pretraining data resulted in improved segmentation performance. SSL models pretrained with this amount of data outperformed baseline supervised models in the computation of clinically-relevant metrics, especially when the performance of supervised learning was low. Our results demonstrate that SSL pretraining using inpainting-based pretext tasks can help increase the robustness of models in label-limited scenarios and reduce worst-case errors that occur with supervised learning.

3.
Article in English | MEDLINE | ID: mdl-34784278

ABSTRACT

OBJECTIVE: Retinal prostheses must be able to activate cells in a selective way in order to restore high-fidelity vision. However, inadvertent activation of far-away retinal ganglion cells (RGCs) through electrical stimulation of axon bundles can produce irregular and poorly controlled percepts, limiting artificial vision. In this work, we aim to provide an algorithmic solution to the problem of detecting axon bundle activation with a bi-directional epiretinal prostheses. METHODS: The algorithm utilizes electrical recordings to determine the stimulation current amplitudes above which axon bundle activation occurs. Bundle activation is defined as the axonal stimulation of RGCs with unknown soma and receptive field locations, typically beyond the electrode array. The method exploits spatiotemporal characteristics of electrically-evoked spikes to overcome the challenge of detecting small axonal spikes. RESULTS: The algorithm was validated using large-scale, single-electrode and short pulse, ex vivo stimulation and recording experiments in macaque retina, by comparing algorithmically and manually identified bundle activation thresholds. For 88% of the electrodes analyzed, the threshold identified by the algorithm was within ±10% of the manually identified threshold, with a correlation coefficient of 0.95. CONCLUSION: This works presents a simple, accurate and efficient algorithm to detect axon bundle activation in epiretinal prostheses. SIGNIFICANCE: The algorithm could be used in a closed-loop manner by a future epiretinal prosthesis to reduce poorly controlled visual percepts associated with bundle activation. Activation of distant cells via axonal stimulation will likely occur in other types of retinal implants and cortical implants, and the method may therefore be broadly applicable.


Subject(s)
Visual Prosthesis , Axons , Electric Stimulation , Retina , Retinal Ganglion Cells
4.
J Neurophysiol ; 118(3): 1457-1471, 2017 09 01.
Article in English | MEDLINE | ID: mdl-28566464

ABSTRACT

Epiretinal prostheses for treating blindness activate axon bundles, causing large, arc-shaped visual percepts that limit the quality of artificial vision. Improving the function of epiretinal prostheses therefore requires understanding and avoiding axon bundle activation. This study introduces a method to detect axon bundle activation on the basis of its electrical signature and uses the method to test whether epiretinal stimulation can directly elicit spikes in individual retinal ganglion cells without activating nearby axon bundles. Combined electrical stimulation and recording from isolated primate retina were performed using a custom multielectrode system (512 electrodes, 10-µm diameter, 60-µm pitch). Axon bundle signals were identified by their bidirectional propagation, speed, and increasing amplitude as a function of stimulation current. The threshold for bundle activation varied across electrodes and retinas, and was in the same range as the threshold for activating retinal ganglion cells near their somas. In the peripheral retina, 45% of electrodes that activated individual ganglion cells (17% of all electrodes) did so without activating bundles. This permitted selective activation of 21% of recorded ganglion cells (7% of expected ganglion cells) over the array. In one recording in the central retina, 75% of electrodes that activated individual ganglion cells (16% of all electrodes) did so without activating bundles. The ability to selectively activate a subset of retinal ganglion cells without axon bundles suggests a possible novel architecture for future epiretinal prostheses.NEW & NOTEWORTHY Large-scale multielectrode recording and stimulation were used to test how selectively retinal ganglion cells can be electrically activated without activating axon bundles. A novel method was developed to identify axon activation on the basis of its unique electrical signature and was used to find that a subset of ganglion cells can be activated at single-cell, single-spike resolution without producing bundle activity in peripheral and central retina. These findings have implications for the development of advanced retinal prostheses.


Subject(s)
Axons/physiology , Neural Prostheses , Retinal Ganglion Cells/physiology , Animals , Electric Stimulation , Evoked Potentials , Female , Macaca mulatta , Male , Sensory Thresholds