Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Brachytherapy ; 19(4): 484-490, 2020.
Article in English | MEDLINE | ID: mdl-32402544

ABSTRACT

PURPOSE: The purpose of this study was to compare an isotropic three-dimensional (3D) T2-weighted sequence sampling perfection with application-optimized contrasts by using flip angle evolution (SPACE) with an axial two-dimensional T2-weighted turbo spin echo (TSE) sequence with regard to overall image quality and the delineation of normal prostate and periprostatic anatomy for low-dose-rate prostate cancer brachytherapy planning evaluation. METHODS AND MATERIALS: Patients (n = 69) with prostate cancer who had pelvic magnetic resonance imaging (MRI) for low-dose-rate brachytherapy treatment planning were included. Three radiologists independently assessed the visibility of nine anatomic structures on each sequence by using a 5-point scale and overall image quality by using a 4-point scale. The significance of the differences in diagnostic performance was tested with a Wilcoxon signed rank test. RESULTS: No significant intersequence differences were found for most (7/9) anatomical structures and overall image quality. The mean scores for visibility of anatomical structures on the 3D SPACE and 2D TSE sequences, respectively, were as follows: the zonal anatomy (3.7; 3.9, p = 0.05), prostate capsule (3.9; 4.0, p = 0.08), neurovascular bundle (2.9; 2.9, p = 0.9), rectoprostatic angle (3.8; 3.8, p = 0.35), rectum (4.2; 4.3, p = 0.26), urethra (3.8; 3.9, p = 0.12), urinary bladder (4.6; 4.6, p = 0.61), and overall image quality (2.9; 2.9, p = 0.33). 3D SPACE was superior for delineation of the genitourinary diaphragm (3.8; 3.6, p = 0.003), whereas 2D TSE was superior for delineation of the seminal vesicles (3.5; 4.0, p < 0.0001). CONCLUSIONS: Anatomic delineation of the prostatic and periprostatic anatomy provided by the 3D SPACE sequence is as robust in quality as that provided by a conventional 2D TSE sequence with superior delineation of the genitourinary diaphragm. For MRI-based brachytherapy treatment planning, the 3D SPACE sequence with subcentimeter isotropic resolution can replace the 2D TSE sequence and be incorporated into standard MRI protocols.


Subject(s)
Anatomic Landmarks/diagnostic imaging , Brachytherapy , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/standards , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Aged , Blood Vessels/diagnostic imaging , Contrast Media , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Peripheral Nerves/diagnostic imaging , Rectum/diagnostic imaging , Retrospective Studies , Seminal Vesicles/diagnostic imaging , Urethra/diagnostic imaging , Urinary Bladder/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...