Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Quant Imaging Med Surg ; 13(9): 6152-6163, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37711827

ABSTRACT

Background: Accurately distinguishing between pleomorphic adenoma (PA) and Warthin tumor (WT) is beneficial for their respective management. Preoperative magnetic resonance imaging (MRI) can provide valuable information due to its excellent soft tissue contrast. This study explored the value of semiquantitative contrast-enhanced MRI parameters in the differential diagnosis of PA and WT. Methods: Data from 106 patients, 62 with PA and 44 with WT (confirmed by histopathology) were retrospectively and consecutively analyzed. The tumor-to-spinal cord contrast ratios (TSc-CR) based on the mean, maximum, and minimum signal intensity (T1-mean TSc-CR, T1-max TSc-CR, and T1-min TSc-CR, respectively) in the early and delayed phases were calculated on contrast-enhanced T1-weighted images as semiquantitative parameters, and then compared between PA and WT. Receiver operating characteristic (ROC) curve analysis and areas under the curve (AUCs) were used to determine the performance of these parameters in the differential diagnosis of PA from WT. Results: Except T1-min TSc-CR in the early phase, all semiquantitative MRI parameters differed significantly between PA and WT (all P<0.05). T1-max TSc-CR showed higher sensitivity {70.45% [95% confidence interval (CI): 0.548-0.832]} and specificity [70.97% (95% CI: 0.581-0.818)] and had a higher AUC [0.707 (95% CI: 0.610-0.791)] in the early phase when using a cutoff value of 1.89. T1-max TSc-CR showed higher sensitivity [88.64% (95% CI: 0.754-0.962)], specificity [72.58% (95% CI: 0.598-0.831)], and AUC [0.854 (95% CI: 0.772-0.915)] in the delayed phase when using a cutoff value of 2.33. The sensitivity, specificity, and AUC were improved to 90.91% (95% CI: 0.783-0.975), 93.55% (95% CI: 0.843-0.982), and 0.960 (95% CI: 0.903-0.988), respectively, after combination of all semiquantitative parameters in the early and delayed phases. The two radiologists had excellent interobserver agreement on TSc-CRs [all interclass correlation coefficient (ICC) >0.75]. Conclusions: Semiquantitative parameters using TSc-CR are valuable in distinguishing PA from WT, and a combination of these parameters can improve the differential diagnostic efficiency.

SELECTION OF CITATIONS
SEARCH DETAIL
...