Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Methods Mol Biol ; 2531: 49-59, 2022.
Article in English | MEDLINE | ID: mdl-35941477

ABSTRACT

Homemade capillaries are a very common practice for the users of capillary electrophoresis (CE), notably in CE-UV. With the advent of the capillary electrophoresis-mass spectrometry coupling since the end of the 1980s, several interfaces have been developed. Among those interfaces, the porous tip sprayer allows great sensitivity at nano flow rates and has been used in numerous applications over the past few years. However, the homemade implementation of a suitable capillary for the porous tip sprayer is more challenging. The porous tip is created by etching the bare-fused silica capillary with hydrofluoric acid. Here we describe the complete process of etching bare-fused silica capillaries, from length cutting to quality control of the newly etched capillary.


Subject(s)
Silicon Dioxide , Spectrometry, Mass, Electrospray Ionization , Capillaries , Electrophoresis, Capillary/methods , Porosity , Silicon Dioxide/chemistry , Spectrometry, Mass, Electrospray Ionization/methods
2.
Electrophoresis ; 42(14-15): 1431-1435, 2021 08.
Article in English | MEDLINE | ID: mdl-33890318

ABSTRACT

CE has been demonstrated to be a useful and powerful separation method for the characterization of charged and neutral molecules. Since the end of the 1980s and the development of the first commercialized CE device, the use of this separation method has continued to grow for academic and industrial research involving inexorably increasing of the number of CE users. Whatever the application domain, each CE user is daily confronted to the same problems often based on basic calculations of separation properties. In order to help the community of CE users to get quickly and easily a lot of information, and desiring to provide a tool running on mobile platforms, CEToolbox has been developed as a free Android application. Within few clicks, CEToolbox offers extensive injection information as injected volume, total capillary volume, proportion and amount of injected sample, rinsing time, and electrical field. Moreover, three additional tabs allow to obtain the calculation of the viscosity and the conductivity of BGE, and the separation flow rates. Finally, a last tab is dedicated to the calculation of electroosmotic mobility and effective mobilities for a maximum of 20 compounds. CEToolbox, which can be downloaded for free on Google and F-Droid application stores, was developed to simplify the daily of CE users regardless of the CE devices.


Subject(s)
Electrophoresis, Capillary , Electric Conductivity , Electroosmosis
3.
Methods Mol Biol ; 2271: 97-106, 2021.
Article in English | MEDLINE | ID: mdl-33908002

ABSTRACT

Glycosylation is a crucial posttranslational modification (PTM) that might affect the safety and efficacy of monoclonal antibodies (mAbs). Capillary electrophoresis-mass spectrometry (CE-MS) enables the characterization of the primary structure of mAbs. A bottom-up proteomic workflow is designed to provide detailed information about the glycosylation. In this chapter, we describe the validated experimental protocol applied for the characterization and relative quantification of mAbs N-glycosylation at the glycopeptide level.


Subject(s)
Electrophoresis, Capillary , Glycoproteins/analysis , Natalizumab/analysis , Protein Processing, Post-Translational , Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry , Glycosylation , Research Design , Workflow
4.
J Chromatogr A ; 1498: 120-127, 2017 May 19.
Article in English | MEDLINE | ID: mdl-28259456

ABSTRACT

The characterization of complex protein mixtures represents one of the biggest challenge in many research fields such as biological or biopharmaceutical sciences. Out of all categories, monoclonal antibodies (mAbs) and related products drawn the most interest due to their strong therapeutic potency and specificity. Because of their intrinsic complexity due to a large number of micro-heterogeneities, there is a crucial need for analytical methods to provide comprehensive in-depth characterization of these proteins. In this work, we developed a methodology using CE-UV/MALDI-MS to perform top-down or middle-down characterization after fraction collection enrichment applied to intact protein and mAbs samples. The performance of the method was evaluated with the rapid separation of three intact protein mixture. Good robustness of CZE separation and quality of MALDI-MS spectra and MALDI-ISD spectra of each protein confirms the usefulness of sample enrichment to obtain adequate quantity of deposed protein for top-down analysis and the proof of principle of the method. In a second step, the method was applied to the middle-down characterization of Fc/2 cetuximab variants. Identification of around 9% sequence coverage of Fc/2 cetuximab fragments allows to conclude on the feasibility of the strategy for middle-down characterization of Fc/2 cetuximab variants using CE-UV/MALDI-MS. Moreover, MALDI-ISD fragmentation of Fc/2 cetuximab variants confirm separation phenomenon based on the formation of Fc/2 dimers with and without C-terminal truncation.


Subject(s)
Antibodies, Monoclonal/analysis , Cetuximab/analysis , Electrophoresis, Capillary/methods , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Amino Acid Sequence , Antibodies, Monoclonal/isolation & purification , Cetuximab/isolation & purification , Dimerization , Immunoglobulin Fc Fragments/analysis , Immunoglobulin Fc Fragments/isolation & purification , Spectrophotometry, Ultraviolet
5.
Anal Chim Acta ; 908: 168-76, 2016 Feb 18.
Article in English | MEDLINE | ID: mdl-26826699

ABSTRACT

Monoclonal antibody (mAb) therapeutics attract the largest concern due to their strong therapeutic potency and specificity. The Fc region of mAbs is common to many new biotherapeutics as biosimilar, antibody drug conjugate or fusion protein. Fc region has consequences for Fc-mediated effector functions that might be desirable for therapeutic applications. As a consequence, there is a continuous need for improvement of analytical methods to enable fast and accurate characterization of biotherapeutics. Capillary zone electrophoresis-Mass spectrometry couplings (CZE-MS) appear really attractive methods for the characterization of biological samples. In this report, we used CZE-MS systems developed in house and native MS infusion to allow precise middle-up characterization of Fc/2 variant of cetuximab. Molecular weights were measured for three Fc/2 charge variants detected in the CZE separation of cetuximab subunits. Two Fc/2 C-terminal lysine variants were identified and separated. As the aim is to understand the presence of three peaks in the CZE separation for two Fc/2 subunits, we developed a strategy using CZE-UV/MALDI-MS and CZE-UV/ESI-MS to evaluate the role of N-glycosylation and C-terminal lysine truncation on the CZE separation. The chemical structure of N-glycosylation expressed on the Fc region of cetuximab does not influence CZE separation while C-terminal lysine is significantly influencing separation. In addition, native MS infusion demonstrated the characterization of Fc/2 dimers at pH 5.7 and 6.8 and the first separation of these dimers using CZE-MS.


Subject(s)
Cetuximab/chemistry , Electrophoresis, Capillary/methods , Mass Spectrometry/methods , Dimerization
6.
Anal Chem ; 87(12): 6240-50, 2015 Jun 16.
Article in English | MEDLINE | ID: mdl-25970692

ABSTRACT

Monoclonal antibodies (mAbs) are highly complex glycoproteins that present a wide range of microheterogeneities that requires multiple analytical methods for full structure assessment and quality control. Capillary zone electrophoresis-mass spectrometry (CZE-MS) couplings, especially by electrospray ionization (ESI), appear to be really attractive methods for the characterization of biological samples. However, due to the presence of non- or medium volatile salts in the background electrolyte (BGE), online CZE-ESI-MS coupling is difficult to implement for mAbs isoforms separation. Here, we report an original strategy to perform off-line CZE-ESI-MS using CZE-UV/fraction collection technology to perform CZE separation, followed by ESI-MS infusion of the different fractions using the capillary electrophoresis-electrospray ionization (CESI) interface as the nanoESI infusion platform. As the aim is to conserve electrophoretic resolution and complete compatibility with ESI-MS without sample treatment, hydroxypropylcellulose (HPC) coated capillary was used to prevent analyte adsorption and asymmetric CZE conditions involving different BGE at both ends of the capillary have been developed. The efficiency of our strategy was validated with the separation of Cetuximab charge variant by the middle-up approach. Molecular weights were measured for six charge variants detected in the CZE separation of Cetuximab subunits. The first three peaks correspond to Fc/2 variants with electrophoretic resolution up to 2.10, and the last three peaks correspond to F(ab')2 variants with average electrophoretic resolution of 1.05. Two Fc/2 C-terminal lysine variants were identified and separated. Moreover, separation of Fc/2 fragments allowed the glycoprofiling of the variants with the characterization of 7 different glycoforms. Regarding the F(ab')2 domain, 8 glycoforms were detected and separated in three different peaks following the presence of N-glycolyl neuraminic acid residues in some glycan structures. This work highlights the potential of CZE technology to perform separation of mAbs especially when they carry sialic acid carbohydrates.


Subject(s)
Cetuximab/isolation & purification , Cetuximab/genetics , Electrophoresis, Capillary , Genetic Variation/genetics , Protein Conformation , Spectrometry, Mass, Electrospray Ionization , Spectrophotometry, Ultraviolet
7.
MAbs ; 6(6): 1464-73, 2014.
Article in English | MEDLINE | ID: mdl-25484058

ABSTRACT

Out of all categories, monoclonal antibody (mAb) therapeutics attract the most interest due to their strong therapeutic potency and specificity. Six of the 10 top-selling drugs are antibody-based therapeutics that will lose patent protection soon. The European Medicines Agency has pioneered the regulatory framework for approval of biosimilar products and approved the first biosimilar antibodies by the end of 2013. As highly complex glycoproteins with a wide range of micro-variants, mAbs require extensive characterization through multiple analytical methods for structure assessment rendering manufacturing control and biosimilarity studies particularly product and time-consuming. Here, capillary zone electrophoresis coupled to mass spectrometry by a sheathless interface (CESI-MS) was used to characterize marketed reference mAbs and their respective biosimilar candidate simultaneously over different facets of their primary structure. CESI-MS/MS data were compared between approved mAbs and their biosimilar candidates to prove/disconfirm biosimilarity regarding recent regulation directives. Using only a single sample injection of 200 fmol, CESI-MS/MS data enabled 100% amino acids (AA) sequence characterization, which allows a difference of even one AA between 2 samples to be distinguished precisely. Simultaneously glycoforms were characterized regarding their structures and position through fragmentation spectra and glycoforms semiquantitative analysis was established, showing the capacity of the developed methodology to detect up to 16 different glycans. Other posttranslational modifications hotspots were characterized while their relative occurrence levels were estimated and compared to biosimilars. These results proved the value of using CESI-MS because the separation selectivity and ionization efficiency provided by the system allowed substantial improvement in the characterization workflow robustness and accuracy. Biosimilarity assessment could be performed routinely with a single injection of each candidate enabling improvements in the biosimilar development pipeline.


Subject(s)
Antibodies, Monoclonal/analysis , Biosimilar Pharmaceuticals/analysis , Electrophoresis, Capillary/methods , Isotachophoresis/methods , Tandem Mass Spectrometry/methods , Amino Acid Sequence , Antibodies, Monoclonal, Humanized/analysis , Cetuximab , Glycosylation , Molecular Sequence Data , Polysaccharides/analysis , Protein Processing, Post-Translational , Reproducibility of Results , Sequence Analysis, Protein , Trastuzumab
8.
Electrophoresis ; 35(20): 2986-95, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25070377

ABSTRACT

mAbs are highly complex proteins that present a wide range of microheterogeneity that requires multiple analytical methods for full structure assessment and quality control. As a consequence, the characterization of mAbs on different levels is particularly product- and time-consuming. CE-MS couplings, especially to MALDI, appear really attractive methods for the characterization of biological samples. In this work, we report the last instrumental development and performance of the first totally automated off-line CE-UV/MALDI-MS/MS. This interface is based on the removal of the original UV cell of the CE apparatus, modification of the spotting device geometry, and creation of an integrated delivery matrix system. The performance of the method was evaluated with separation of five intact proteins and a tryptic digest mixture of nine proteins. Intact protein application shows the acquisition of electropherograms with high resolution and high repeatability. In the peptide mapping approach, a total number of 154 unique identified peptides were characterized using MS/MS spectra corresponding to average sequence coverage of 64.1%. Comparison with NanoLC/MALDI-MS/MS showed complementarity at the peptide level with an increase of 42% when using CE/MALDI-MS coupling. Finally, this work represents the first analysis of intact mAb charge variants by CZE using an MS detection. Moreover, using a peptide mapping approach CE-UV/MALDI-MS/MS fragmentation allowed 100% sequence coverage of the light chain and 92% of the heavy chain, and the separation of four major glycosylated peptides and their structural characterization.


Subject(s)
Antibodies, Monoclonal, Humanized/analysis , Electrophoresis, Capillary/instrumentation , Peptide Mapping/instrumentation , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/instrumentation , Antibodies, Monoclonal, Humanized/chemistry , Electrophoresis, Capillary/methods , Equipment Design , Peptide Fragments/analysis , Peptide Fragments/chemistry , Peptide Mapping/methods , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Trypsin
SELECTION OF CITATIONS
SEARCH DETAIL
...