Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Diabetes Res Clin Pract ; 154: 66-74, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31128134

ABSTRACT

AIMS: Incorrectly fitting shoes are implicated in callus formation and a significant proportion of diabetic foot ulcers, yet remain surprisingly prevalent. We review the current shoe fit guidelines for consistency and discuss ways in which technology may assist us in standardising methods of footwear assessment. METHODS: Narrative review. RESULTS: Incorrectly fitted shoes are implicated in the development of some diabetic foot ulcers yet surprisingly there's no consensus on shoe fit, despite substantial spending on prescription footwear. Suggested toe gaps vary from 6 to 20 mm and measurement methods also vary from Brannock Devices and callipers to manual measurement. CONCLUSIONS: To prevent fit-related foot ulceration, we need to standardise our biomechanical definition of fit. Future research should (1) evaluate the potential use of 3D scanning technology to provide a standardised means of capturing foot morphology; (2) develop a working biomechanical definition of fit, including toe gap through the identification of key physiological markers that capture and predict dynamic foot shape changes during different physical activities and body weight loading conditions; and (3) determine whether changes in dynamic foot shape of those with diabetes differs from those without, impacting on their shoe fitting needs, potentially necessitating specialist footwear at an earlier stage to avoid ulceration.


Subject(s)
Diabetic Foot/prevention & control , Foot/anatomy & histology , Shoes/standards , Body Weights and Measures , Foot/physiology , Humans
2.
Disabil Rehabil ; 41(3): 348-356, 2019 02.
Article in English | MEDLINE | ID: mdl-29065718

ABSTRACT

BACKGROUND: This study reviewed the current state of maxillofacial rehabilitation in resource-limited nations. METHOD: A rigorous literature review was undertaken using several technical and clinical databases using a variety of key words pertinent to maxillofacial prosthetic rehabilitation and resource-limited areas. In addition, interviews were conducted with researchers, clinicians and prosthetists that had direct experience of volunteering or working in resource-limited countries. RESULTS: Results from the review and interviews suggest rehabilitating patients in resource-limited countries remains challenging and efforts to improve the situation requires a multifactorial approach. CONCLUSIONS: In conclusion, public health awareness programmes to reduce the causation of injuries and bespoke maxillofacial prosthetics training programmes to suit these countries, as opposed to attempting to replicate Western training programmes. It is also possible that usage of locally sourced and cheaper materials and the use of low-cost technologies could greatly improve maxillofacial rehabilitation efforts in these localities. Implications for Rehabilitation More information and support needs to be provided to maxillofacial defect/injuries patients and to their families or guardians in a culturally sensitive manner by governments. The health needs, economic and psychological needs of the patients need to be taken into account during the rehabilitation process by clinicians and healthcare organizations. The possibility of developing training programs to suit these resource limited countries and not necessarily follow conventional fabrication methods must be looked into further by educational entities.


Subject(s)
Maxillofacial Prosthesis Implantation/rehabilitation , Maxillofacial Prosthesis , Developing Countries , Health Care Rationing , Humans , Maxillofacial Prosthesis/economics , Maxillofacial Prosthesis/psychology
3.
ACS Biomater Sci Eng ; 5(10): 5525-5538, 2019 Oct 14.
Article in English | MEDLINE | ID: mdl-33464072

ABSTRACT

Bioengineered skeletal muscle tissues benefit from dynamic culture environments which facilitate the appropriate provision of nutrients and removal of cellular waste products. Biologically compatible perfusion systems hold the potential to enhance the physiological biomimicry of in vitro tissues via dynamic culture, in addition to providing technological advances in analytical testing and live cellular imaging for analysis of cellular development. To meet such diverse requirements, perfusion systems require the capacity and adaptability to incorporate multiple cell laden constructs of both monolayer and bioengineered tissues. This work reports perfusion systems produced using additive manufacturing technology for the in situ phenotypic development of myogenic precursor cells in monolayer and bioengineered tissue. Biocompatibility of systems 3D printed using stereolithography (SL), laser sintering (LS), and PolyJet outlined preferential morphological development within both SL and LS devices. When exposed to intermittent perfusion in the monolayer, delayed yet physiologically representative cellular proliferation, MyoD and myogenin transcription of C2C12 cells was evident. Long-term (8 days) intermittent perfusion of monolayer cultures outlined viable morphological and genetic in situ differentiation for the live cellular imaging of myogenic development. Continuous perfusion cultures (13 days) of bioengineered skeletal muscle tissues outlined in situ myogenic differentiation, forming mature multinucleated myotubes. Here, reductions in IL-1ß and TNF-α inflammatory cytokines, myostatin, and MuRF-1 atrophic mRNA expression were observed. Comparable myosin heavy chain (MyHC) isoform transcription profiles were evident between conditions; however, total mRNA expression was reduced in perfusion conditions. Decreased transcription of MuRF1 and subsequent reduced ubiquitination of the MyHC protein allude to a decreased requirement for transcription of MyHC isoform transcripts. Together, these data appear to indicate that 3D printed perfusion systems elicit enhanced stability of the culture environment, resulting in a reduced basal requirement for MyHC gene expression within bioengineered skeletal muscle tissue.

4.
Materials (Basel) ; 11(6)2018 May 30.
Article in English | MEDLINE | ID: mdl-29848959

ABSTRACT

The objective of this study was to determine the effect of plant based antimicrobial solutions specifically tea tree and Manuka oil on facial silicone elastomers. The purpose of this in vitro study was to evaluate the effect of disinfection with plant extract solution on mechanical properties and morphology on the silicone elastomer. Test specimens were subjected to disinfection using tea tree oil, Manuka oil and the staphylococcus epidermidis bacteria. Furthermore, a procedure duration was used in the disinfection process to simulate up to one year of usage. Over 500 test specimens were fabricated for all tests performed namely hardness, elongation, tensile, tear strength tests, visual inspection and lastly surface characterization using SEM. A repeated measures ANOVA revealed that hardness and elongation at break varied significantly over the time period, whereas this was not observed in the tear and tensile strength parameters of the test samples.

5.
Macromol Biosci ; 18(7): e1800113, 2018 07.
Article in English | MEDLINE | ID: mdl-29900676

ABSTRACT

The integration of additive manufacturing (AM) technology within biological systems holds significant potential, specifically when refining the methods utilized for the creation of in vitro models. Therefore, examination of cellular interaction with the physical/physicochemical properties of 3D-printed polymers is critically important. In this work, skeletal muscle (C2 C12 ), neuronal (SH-SY5Y) and hepatic (HepG2) cell lines are utilized to ascertain critical evidence of cellular behavior in response to 3D-printed candidate polymers: Clear-FL (stereolithography, SL), PA-12 (laser sintering, LS), and VeroClear (PolyJet). This research outlines initial critical evidence for a framework of polymer/AM process selection when 3D printing biologically receptive scaffolds, derived from industry standard, commercially available AM instrumentation. C2 C12 , SH-SY5Y, and HepG2 cells favor LS polymer PA-12 for applications in which cellular adherence is necessitated. However, cell type specific responses are evident when cultured in the chemical leachate of photopolymers (Clear-FL and VeroClear). With the increasing prevalence of 3D-printed biointerfaces, the development of rigorous cell type specific biocompatibility data is imperative. Supplementing the currently limited database of functional 3D-printed biomaterials affords the opportunity for experiment-specific AM process and polymer selection, dependent on biological application and intricacy of design features required.


Subject(s)
Biocompatible Materials/chemical synthesis , Polymers/chemical synthesis , Printing, Three-Dimensional , Animals , Biocompatible Materials/pharmacology , Cell Adhesion/drug effects , Cell Line , Cell Line, Tumor , Cell Survival/drug effects , Hep G2 Cells , Humans , Mice , Myoblasts/cytology , Myoblasts/drug effects , Myoblasts/metabolism , Neurons/cytology , Neurons/drug effects , Neurons/metabolism , Photochemical Processes , Polymers/pharmacology
6.
Proc Inst Mech Eng H ; 231(9): 881-897, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28689470

ABSTRACT

Rheumatoid arthritis is a chronic disease affecting the joints. Treatment can include immobilisation of the affected joint with a custom-fitting splint, which is typically fabricated by hand from low temperature thermoplastic, but the approach poses several limitations. This study focused on the evaluation, by finite element analysis, of additive manufacturing techniques for wrist splints in order to improve upon the typical splinting approach. An additive manufactured/3D printed splint, specifically designed to be built using Objet Connex multi-material technology and a virtual model of a typical splint, digitised from a real patient-specific splint using three-dimensional scanning, were modelled in computer-aided design software. Forty finite element analysis simulations were performed in flexion-extension and radial-ulnar wrist movements to compare the displacements and the stresses. Simulations have shown that for low severity loads, the additive manufacturing splint has 25%, 76% and 27% less displacement in the main loading direction than the typical splint in flexion, extension and radial, respectively, while ulnar values were 75% lower in the traditional splint. For higher severity loads, the flexion and extension movements resulted in deflections that were 24% and 60%, respectively, lower in the additive manufacturing splint. However, for higher severity loading, the radial defection values were very similar in both splints and ulnar movement deflection was higher in the additive manufacturing splint. A physical prototype of the additive manufacturing splint was also manufactured and was tested under normal conditions to validate the finite element analysis data. Results from static tests showed maximum displacements of 3.46, 0.97, 3.53 and 2.51 mm flexion, extension, radial and ulnar directions, respectively. According to these results, the present research argues that from a technical point of view, the additive manufacturing splint design stands at the same or even better level of performance in displacements and stress values in comparison to the typical low temperature thermoplastic approach and is therefore a feasible approach to splint design and manufacture.


Subject(s)
Computer-Aided Design , Finite Element Analysis , Plastics , Printing, Three-Dimensional , Splints , Temperature , Wrist , Humans
7.
Lab Chip ; 13(23): 4583-90, 2013 Dec 07.
Article in English | MEDLINE | ID: mdl-24100659

ABSTRACT

We review the use of additive manufacturing (AM) as a novel manufacturing technique for the production of milli-scale reactor systems. Five well-developed additive manufacturing techniques: stereolithography (SL), multi-jet modelling (MJM), selective laser melting (SLM), laser sintering (LS) and fused deposition modelling (FDM) were used to manufacture a number of miniaturised reactors which were tested using a range of organic and inorganic reactions.

SELECTION OF CITATIONS
SEARCH DETAIL
...