Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Echocardiography ; 29(6): 751­756, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22962695

ABSTRACT

We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.


Subject(s)
Carcinoid Heart Disease/complications , Carcinoid Heart Disease/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/etiology , Heart Valves/diagnostic imaging , Computer Systems , Female , Humans , Middle Aged
2.
Echocardiography ; 29(5): 620-30, 2012 May.
Article in English | MEDLINE | ID: mdl-22537236

ABSTRACT

We compared findings from intraoperative live/real time three-dimensional transesophageal echocardiography (3DTEE) and two-dimensional transesophageal echocardiography (2DTEE) with surgery in 67 patients having aortic aneurysm and/or aortic dissection. Of these, 20 patients had aortic aneurysm without dissection, 21 aortic aneurysm and dissection, and 26 aortic dissection without aneurysm. 3DTEE diagnosed the type and location of aneurysm correctly in all patients unlike 2DTEE, which missed an aneurysm in one case. There were four cases of aortic aneurysm rupture. Three of them were diagnosed by 3DTEE but only one by 2DTEE, and one missed by both techniques. The mouth of saccular aneurysm, site of aortic aneurysm rupture, and communication sites between perfusing and nonperfusing lumens of aortic dissection could be viewed en face only with 3DTEE, enabling comprehensive measurements of their area and dimensions as well as increasing the confidence level of their diagnosis. In all patients with aortic dissection, 3DTEE enabled a more confident diagnosis of dissection because the dissection flap when viewed en face presented as a sheet of tissue rather than a linear echo seen on 2DTEE which can be confused with an artifact. 2DTEE missed dissection in one patient. In six cases the dissection flap involved the right coronary artery orifice by 3DTEE and surgery. These were missed by 2DTEE. Aortic regurgitation severity was more comprehensively assessed by 3DTEE than 2DTEE. Aneurysm size by 3DTEE correlated well with 2DTEE and surgery/computed tomography scan. In conclusion, 3DTEE provides incremental information over 2DTEE in patients with aortic aneurysm and dissection.


Subject(s)
Aortic Aneurysm/diagnostic imaging , Aortic Dissection/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography/methods , Adult , Aged , Aged, 80 and over , Computer Systems , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
3.
Echocardiography ; 29(6): 742-4, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22404395

ABSTRACT

We report a case of an elderly patient in whom live/real time three-dimensional transesophageal echocardiography (3DTEE) provided definitive diagnosis of mitral-aortic intervalvular fibrosa abscess. This could not be done by two-dimensional transthoracic echocardiography (2DTTE) and two-dimensional transesophageal echocardiography (2DTEE). 3DTEE was also helpful in ruling out associated mitral valve endocarditis, which was initially suspected by 2DTEE leading to a mitral valve sparing surgery. Thus, 3DTEE provided incremental information over 2DTTE and 2DTEE in this patient.


Subject(s)
Abscess/diagnostic imaging , Abscess/pathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/pathology , Echocardiography, Three-Dimensional/methods , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/pathology , Aged , Diagnosis, Differential , Fibrosis/diagnostic imaging , Fibrosis/pathology , Humans , Male
4.
Echocardiography ; 29(3): E72-7, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22432650

ABSTRACT

We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.


Subject(s)
Carcinoid Heart Disease/complications , Carcinoid Heart Disease/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/etiology , Computer Systems , Female , Humans , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...