Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
Add more filters










Publication year range
1.
Adv Sci (Weinh) ; 11(26): e2400261, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38659228

ABSTRACT

Metamaterials hold significant promise for enhancing the imaging capabilities of magnetic resonance imaging (MRI) machines as an additive technology, due to their unique ability to enhance local magnetic fields. However, despite their potential, the metamaterials reported in the context of MRI applications have often been impractical. This impracticality arises from their predominantly flat configurations and their susceptibility to shifts in resonance frequencies, preventing them from realizing their optimal performance. Here, a computational method for designing wearable and tunable metamaterials via freeform auxetics is introduced. The proposed computational-design tools yield an approach to solving the complex circle packing problems in an interactive and efficient manner, thus facilitating the development of deployable metamaterials configured in freeform shapes. With such tools, the developed metamaterials may readily conform to a patient's knee, ankle, head, or any part of the body in need of imaging, and while ensuring an optimal resonance frequency, thereby paving the way for the widespread adoption of metamaterials in clinical MRI applications.

2.
ArXiv ; 2023 Nov 21.
Article in English | MEDLINE | ID: mdl-38045478

ABSTRACT

Metamaterials hold significant promise for enhancing the imaging capabilities of MRI machines as an additive technology, due to their unique ability to enhance local magnetic fields. However, despite their potential, the metamaterials reported in the context of MRI applications have often been impractical. This impracticality arises from their predominantly flat configurations and their susceptibility to shifts in resonance frequencies, preventing them from realizing their optimal performance. Here, we introduce a computational method for designing wearable and tunable metamaterials via freeform auxetics. The proposed computational-design tools yield an approach to solving the complex circle packing problems in an interactive and efficient manner, thus facilitating the development of deployable metamaterials configured in freeform shapes. With such tools, the developed metamaterials may readily conform to a patient's kneecap, ankle, head, or any part of the body in need of imaging, and while ensuring an optimal resonance frequency, thereby paving the way for the widespread adoption of metamaterials in clinical MRI applications.

3.
Micromachines (Basel) ; 14(4)2023 Mar 27.
Article in English | MEDLINE | ID: mdl-37420973

ABSTRACT

A common problem in deformable mirror assembly is that the adhesion of actuators to an optical mirror face sheet introduces unwanted topography due to large local stresses generated at the adhesive joint. A new approach to minimizing that effect is described, with inspiration taken from St. Venant's principle, a fundamental precept in solid mechanics. It is demonstrated that moving the adhesive joint to the end of a slender post extending from the face sheet largely eliminates deformation due to adhesive stresses. A practical implementation of this design innovation is described, using silicon-on-insulator wafers and deep reactive ion etching. Simulation and experiments validate the effectiveness of the approach, reducing stress-induced topography on a test structure by a factor of 50. A prototype electromagnetic DM using this design approach is described, and its actuation is demonstrated. This new design can benefit a wide range of DMs that rely on actuator arrays that are adhesively bonded to a mirror face sheet.

4.
Front Bioeng Biotechnol ; 11: 1177688, 2023.
Article in English | MEDLINE | ID: mdl-37251575

ABSTRACT

Introduction: Three dimensional engineered cardiac tissues (3D ECTs) have become indispensable as in vitro models to assess drug cardiotoxicity, a leading cause of failure in pharmaceutical development. A current bottleneck is the relatively low throughput of assays that measure spontaneous contractile forces exerted by millimeter-scale ECTs typically recorded through precise optical measurement of deflection of the polymer scaffolds that support them. The required resolution and speed limit the field of view to at most a few ECTs at a time using conventional imaging. Methods: To balance the inherent tradeoff among imaging resolution, field of view and speed, an innovative mosaic imaging system was designed, built, and validated to sense contractile force of 3D ECTs seeded on a 96-well plate. Results: The system performance was validated through real-time, parallel contractile force monitoring for up to 3 weeks. Pilot drug testing was conducted using isoproterenol. Discussion: The described tool increases contractile force sensing throughput to 96 samples per measurement; significantly reduces cost, time and labor needed for preclinical cardiotoxicity assay using 3D ECT. More broadly, our mosaicking approach is a general way to scale up image-based screening in multi-well formats.

5.
IEEE Trans Biomed Eng ; 70(7): 2237-2245, 2023 07.
Article in English | MEDLINE | ID: mdl-37021994

ABSTRACT

Three-dimensional engineered heart tissues (EHTs) derived from human induced pluripotent stem cells (iPSCs) have become an important resource for both drug toxicity screening and research on heart disease. A key metric of EHT phenotype is the contractile (twitch) force with which the tissue spontaneously beats. It is well-known that cardiac muscle contractility - its ability to do mechanical work - depends on tissue prestrain (preload) and external resistance (afterload). OBJECTIVES: Here, we demonstrate a technique to control afterload while monitoring contractile force exerted by EHTs. METHODS: We developed an apparatus that can regulate EHT boundary conditions using real-time feedback control. The system is comprised of a pair of piezoelectric actuators that can strain the scaffold and a microscope that can measure EHT force and length. Closed loop control allows dynamic regulation of effective EHT boundary stiffness. RESULTS: When controlled to switch instantaneously from auxotonic to isometric boundary conditions, EHT twitch force immediately doubled. Changes in EHT twitch force as a function of effective boundary stiffness were characterized and compared to twitch force in auxotonic conditions. CONCLUSION: EHT contractility can be regulated dynamically through feedback control of effective boundary stiffness. SIGNIFICANCE: The capacity to alter the mechanical boundary conditions of an engineered tissue dynamically offers a new way to probe tissue mechanics. This could be used to mimic afterload changes that occur naturally in disease, or to improve mechanical techniques for EHT maturation.


Subject(s)
Induced Pluripotent Stem Cells , Myocytes, Cardiac , Humans , Myocardium , Myocardial Contraction/physiology , Tissue Engineering/methods
6.
Front Neurosci ; 16: 880859, 2022.
Article in English | MEDLINE | ID: mdl-35692424

ABSTRACT

Three-photon microscopy (3PM) was shown to allow deeper imaging than two-photon microscopy (2PM) in scattering biological tissues, such as the mouse brain, since the longer excitation wavelength reduces tissue scattering and the higher-order non-linear excitation suppresses out-of-focus background fluorescence. Imaging depth and resolution can further be improved by aberration correction using adaptive optics (AO) techniques where a spatial light modulator (SLM) is used to correct wavefront aberrations. Here, we present and analyze a 3PM AO system for in vivo mouse brain imaging. We use a femtosecond source at 1300 nm to generate three-photon (3P) fluorescence in yellow fluorescent protein (YFP) labeled mouse brain and a microelectromechanical (MEMS) SLM to apply different Zernike phase patterns. The 3P fluorescence signal is used as feedback to calculate the amount of phase correction without direct phase measurement. We show signal improvement in the cortex and the hippocampus at greater than 1 mm depth and demonstrate close to diffraction-limited imaging in the cortical layers of the brain, including imaging of dendritic spines. In addition, we characterize the effective volume for AO correction within brain tissues, and discuss the limitations of AO correction in 3PM of mouse brain.

7.
J Opt Soc Am A Opt Image Sci Vis ; 39(3): 459-469, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35297430

ABSTRACT

We develop a novel data-driven method for deformable mirror (DM) control. The developed method updates both the DM model and DM control actions that produce desired mirror surface shapes. The novel method explicitly takes into account actuator constraints and couples a feedback-control algorithm with an algorithm for recursive estimation of DM influence function models. We also explore the possibility of using Walsh basis functions for DM control. By expressing the desired and observed mirror surface shapes as sums of Walsh pattern matrices, we formulate the control problem in the 2D Walsh basis domain. We thoroughly experimentally verify the developed approach on a 140-actuator MEMS DM, developed by Boston Micromachines. Our results show that the novel method produces the root-mean-square surface error in the 14-40 nanometer range. These results can additionally be improved by tuning the control and estimation parameters. The developed approach is also applicable to other DM types such as segmented DMs.

8.
Adv Mater ; 34(6): e2109032, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34865253

ABSTRACT

Auxetics refers to structures or materials with a negative Poisson's ratio, thereby capable of exhibiting counterintuitive behaviors. Herein, auxetic structures are exploited to design mechanically tunable metamaterials in both planar and hemispherical configurations operating at megahertz (MHz) frequencies, optimized for their application to magnetic resonance imaging (MRI). Specially, the reported tunable metamaterials are composed of arrays of interjointed unit cells featuring metallic helices, enabling auxetic patterns with a negative Poisson's ratio. The deployable deformation of the metamaterials yields an added degree of freedom with respect to frequency tunability through the resultant modification of the electromagnetic interactions between unit cells. The metamaterials are fabricated using 3D printing technology and an ≈20 MHz frequency shift of the resonance mode is enabled during deformation. Experimental validation is performed in a clinical (3.0 T) MRI system, demonstrating that the metamaterials enable a marked boost in radiofrequency field strength under resonance-matched conditions, ultimately yielding a dramatic increase in the signal-to-noise ratio (≈4.5×) of MRI. The tunable metamaterials presented herein offer a novel pathway toward the practical utilization of metamaterials in MRI, as well as a range of other emerging applications.

9.
Opt Express ; 29(21): 33741-33759, 2021 Oct 11.
Article in English | MEDLINE | ID: mdl-34809180

ABSTRACT

We develop a simple and effective control method for accurate control of deformable mirrors (DMs). For a desired DM surface profile and using batches of observed surface profile data, the proposed method adaptively determines both a DM model (influence matrix) and control actions that produce the desired surface profile with good accuracy. In the first iteration, the developed method estimates a DM influence matrix by solving a multivariable least-squares problem. This matrix is then used to compute the control actions by solving a constrained least-squares problem. Then, the computed actions are randomly perturbed and applied to the DM to generate a new batch of surface profile data. The new data batch is used to estimate a new influence matrix that is then used to re-compute control actions. This procedure is repeated until convergence is achieved. The method is experimentally tested on a Boston Micromachines DM with 140 micro-electronic-mechanical-system actuators. Our experimental results show that the developed control approach can achieve accurate correction despite significant DM nonlinearities. Using only a few control iterations, the developed method is able to produce a surface profile root-mean-square error that varies from 5 - 30 [nm] for most of the tested Zernike wave-front modes without using direct feedback control. These results can additionally be improved by using larger data batches and more iterations or by combining the developed approach with feedback control. Finally, as we experimentally demonstrate, the developed method can be used to estimate a DM model that can effectively be used for a single-step open-loop DM control.

10.
Nat Methods ; 18(10): 1259-1264, 2021 10.
Article in English | MEDLINE | ID: mdl-34608309

ABSTRACT

Understanding complex biological systems requires visualizing structures and processes deep within living organisms. We developed a compact adaptive optics module and incorporated it into two- and three-photon fluorescence microscopes, to measure and correct tissue-induced aberrations. We resolved synaptic structures in deep cortical and subcortical areas of the mouse brain, and demonstrated high-resolution imaging of neuronal structures and somatosensory-evoked calcium responses in the mouse spinal cord at great depths in vivo.


Subject(s)
Neuroimaging/methods , Optics and Photonics/methods , Animals , Bacterial Proteins , Embryo, Nonmammalian , Female , Green Fluorescent Proteins , Luminescent Proteins , Male , Mice , Zebrafish
11.
Opt Express ; 28(20): 28843-28857, 2020 Sep 28.
Article in English | MEDLINE | ID: mdl-33114794

ABSTRACT

Detecting low energy photons, such as photons in the long-wave infrared range, is a technically challenging proposition using naturally occurring materials. In order to address this challenge, we herein demonstrate a micro-bolometer featuring an integrated metamaterial absorber (MA), which takes advantage of the resonant absorption and frequency selective properties of the MA. Importantly, our micro-bolometer exhibits polarization insensitivity and high absorption due to a novel metal-insulator-metal (MIM) absorber design, operating at 8-12 µm wavelength. The metamaterial structures we report herein feature an interconnected design, optimized towards their application to micro-bolometer-based, long-wave infrared detection. The micro-bolometers were fabricated using a combination of conventional photolithography and electron beam lithography (EBL), the latter owing to the small feature sizes within the design. The absorption response was designed using the coupled mode theory (CMT) and the finite integration technique, with the fabricated devices characterized using Fourier-transform infrared spectroscopy (FTIR). The metamaterial-based micro-bolometer exhibits a responsivity of approximately 198 V/W over the 8-12 µm wavelength regime, detectivity of ∼ 0.6 × 109 Jones, thermal response time of ∼ 3.3 ms, and a noise equivalent temperature difference (NETD) of ∼33 mK under 1mA biasing current at room-temperature and atmosphere pressure. The ultimate detectivity and NETD are limited by Johnson noise and heat loss with thermal convection through air; however, further optimization could be achieved by reducing the thermal conductivity via vacuum packaging. Under vacuum conditions, the detectivity may be increased in excess of two-fold, to ∼ 1.5 × 109 Jones. Finally, an infrared image of a soldering iron was generated using a single-pixel imaging process, serving as proof-of-concept of this detection platform. The results presented in this work pave the road towards high-efficiency and frequency-selective detection in the long-wave infrared range through the integration of infrared MAs with micro-bolometers.

12.
Opt Express ; 28(20): 30210-30221, 2020 Sep 28.
Article in English | MEDLINE | ID: mdl-33114904

ABSTRACT

Operable under ambient light and providing chemical selectivity, stimulated Raman scattering (SRS) microscopy opens a new window for imaging molecular events on a human subject, such as filtration of topical drugs through the skin. A typical approach for volumetric SRS imaging is through piezo scanning of an objective lens, which often disturbs the sample and offers a low axial scan rate. To address these challenges, we have developed a deformable mirror-based remote-focusing SRS microscope, which not only enables high-quality volumetric chemical imaging without mechanical scanning of the objective but also corrects the system aberrations simultaneously. Using the remote-focusing SRS microscope, we performed volumetric chemical imaging of living cells and captured in real time the dynamic diffusion of topical chemicals into human sweat pores.


Subject(s)
Molecular Imaging/methods , Nonlinear Optical Microscopy/instrumentation , Pancreatic Neoplasms/diagnostic imaging , Algorithms , Humans , Nonlinear Optical Microscopy/methods , Spectrum Analysis, Raman/methods , Tumor Cells, Cultured
13.
Adv Sci (Weinh) ; 7(19): 2001443, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33042755

ABSTRACT

Breaking Lorentz reciprocity is fundamental to an array of functional radiofrequency (RF) and optical devices, such as isolators and circulators. The application of external excitation, such as magnetic fields and spatial-temporal modulation, has been employed to achieve nonreciprocal responses. Alternatively, nonlinear effects may also be employed to break reciprocity in a completely passive fashion. Herein, a coupled system comprised of linear and nonlinear meta-atoms that achieves nonreciprocity based on the coupling and frequency detuning of its constituent meta-atoms is presented. An analytical model is developed based on the coupled mode theory (CMT) in order to design and optimize the nonreciprocal meta-atoms in this coupled system. Experimental demonstration of an RF isolator is performed, and the contrast between forward and backward propagation approximates 20 dB. Importantly, the use of the CMT model developed herein enables a generalizable capacity to predict the limitations of nonlinearity-based nonreciprocity, thereby facilitating the development of novel approaches to breaking Lorentz reciprocity. The CMT model and implementation scheme presented in this work may be deployed in a wide range of applications, including integrated photonic circuits, optical metamaterials, and metasurfaces, among others.

14.
Nat Methods ; 17(3): 283-286, 2020 03.
Article in English | MEDLINE | ID: mdl-32042186

ABSTRACT

Multiphoton microscopy has gained enormous popularity because of its unique capacity to provide high-resolution images from deep within scattering tissue. Here, we demonstrate video-rate multiplane imaging with two-photon microscopy by performing near-instantaneous axial scanning while maintaining three-dimensional micrometer-scale resolution. Our technique, termed reverberation microscopy, enables the monitoring of neuronal populations over large depth ranges and can be implemented as a simple add-on to a conventional design.


Subject(s)
Brain/diagnostic imaging , Microscopy, Fluorescence, Multiphoton/methods , Motor Cortex/diagnostic imaging , Neurons/physiology , Olfactory Bulb/diagnostic imaging , Acoustics , Animals , Female , Imaging, Three-Dimensional , Mice , Mice, Inbred C57BL , Optics and Photonics , Phantoms, Imaging , Photons , Scattering, Radiation , Signal-To-Noise Ratio
15.
Biomed Opt Express ; 9(4): 1771-1782, 2018 Apr 01.
Article in English | MEDLINE | ID: mdl-29675318

ABSTRACT

High-speed volumetric imaging represents a challenge in microscopy applications. We demonstrate a technique for acquiring volumetric images based on the extended depth of field microscopy with a fast focal scan and modulated illumination. By combining two frames with different illumination ramps, we can perform local depth ranging of the sample at speeds of up to half the camera frame rate. Our technique is light efficient, provides diffraction-limited resolution, enables axial localization that is largely independent of sample size, and can be operated with any standard widefield microscope based on fluorescence or darkfield contrast as a simple add-on. We demonstrate the accuracy of axial localization and applications of the technique to various dynamic extended samples, including in-vivo mouse brain.

16.
Biomed Opt Express ; 9(12): 6145-6153, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-31065419

ABSTRACT

We present a fast label-free computational flow cytometer based on a strategy of compressive imaging. Scattered light from flowing objects is sub-divided into user-defined basis patterns by a deformable mirror and routed to different detectors associated with each pattern. The patterns can be optimized to be matched to the object features of interest, thus facilitating object identification and separation. Compared to conventional scanning flow cytometers, our technique provides increased information capacity without sacrificing flow velocity. Unique features of our matched-filter strategy are that it can simultaneously probe multiple objects throughout large fields of view with long depths of field. In our proof-of-concept demonstrations, we achieve throughputs of over 10,000 particles/s, working at flow velocities of over 1m/s.

17.
Opt Lett ; 42(20): 4183-4186, 2017 Oct 15.
Article in English | MEDLINE | ID: mdl-29028043

ABSTRACT

Fast imaging over large volumes can be obtained in a simple manner with extended-depth-of-field (EDOF) microscopy. A standard technique of Wiener deconvolution can correct for the blurring inherent in EDOF images. We compare Wiener deconvolution with an alternative, parameter-free technique based on the dual reconstruction of fluorescence and absorption layers in a sample. This alternative technique provides significantly enhanced reconstruction contrast owing to a quadratic positivity constraint that intrinsically favors sparse solutions. We demonstrate the advantages of this technique with mouse neuronal images acquired in vivo.


Subject(s)
Brain/diagnostic imaging , Microscopy, Fluorescence/methods , Animals , Fluorescence , Mice , Physical Phenomena
18.
Opt Lett ; 42(5): 995-998, 2017 Mar 01.
Article in English | MEDLINE | ID: mdl-28248351

ABSTRACT

We present a wide-field fluorescence microscopy add-on that provides a fast, light-efficient extended depth-of-field (EDOF) using a deformable mirror with an update rate of 20 kHz. Out-of-focus contributions in the raw EDOF images are suppressed with a deconvolution algorithm derived directly from the microscope 3D optical transfer function. Demonstrations of the benefits of EDOF microscopy are shown with GCaMP-labeled mouse brain tissue.

20.
J Biomed Opt ; 21(12): 121504, 2016 12 01.
Article in English | MEDLINE | ID: mdl-27653793

ABSTRACT

We describe a wavefront sensor strategy for the implementation of adaptive optics (AO) in microscope applications involving thick, scattering media. The strategy is based on the exploitation of multiple scattering to provide oblique back illumination of the wavefront-sensor focal plane, enabling a simple and direct measurement of the flux-density tilt angles caused by aberrations at this plane. Advantages of the sensor are that it provides a large measurement field of view (FOV) while requiring no guide star, making it particularly adapted to a type of AO called conjugate AO, which provides a large correction FOV in cases when sample-induced aberrations arise from a single dominant plane (e.g., the sample surface). We apply conjugate AO here to widefield (i.e., nonscanning) fluorescence microscopy for the first time and demonstrate dynamic wavefront correction in a closed-loop implementation.

SELECTION OF CITATIONS
SEARCH DETAIL
...