Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Chest ; 94(3): 663-5, 1988 Sep.
Article in English | MEDLINE | ID: mdl-2842116

ABSTRACT

We describe a patient in whom respiratory failure, due to extreme neuromuscular weakness, was produced by procainamide intoxication superimposed on a peripheral neuropathy secondary to long-term amiodarone therapy. Respiratory failure reversed rapidly after procainamide was discontinued, and the serum level fell to a therapeutic range.


Subject(s)
Amiodarone/adverse effects , Peripheral Nervous System Diseases/chemically induced , Procainamide/poisoning , Respiratory Insufficiency/chemically induced , Humans , Male , Middle Aged , Neuromuscular Junction/drug effects , Neuromuscular Junction/physiopathology , Respiratory Insufficiency/physiopathology , Respiratory Muscles/drug effects , Respiratory Muscles/innervation , Respiratory Muscles/physiopathology
2.
Ann Thorac Surg ; 43(4): 406-8, 1987 Apr.
Article in English | MEDLINE | ID: mdl-3551860

ABSTRACT

To explore the possibility of performing percutaneous lung biopsy safely in patients mechanically ventilated with positive-end expiratory pressure (PEEP), transthoracic needle biopsy was performed in 16 anesthetized mongrel dogs mechanically ventilated with 10 cm H2O of PEEP. To obtain the biopsy sample, a 25-gauge "skinny needle" was passed through a 20-gauge sheath and placed up to 6.25 cm deep. After satisfactory samples were obtained, both needles were withdrawn in the control group, but in the treated group, the outer sheath was used to inject 0.5 ml of isobutyl 2-cyanoacrylate to seal the needle track. Pneumothorax was present in 7 (87.5%) of 8 dogs in the control group and in 2 (25%) of 8 dogs in the treated group (p = .0147). Lung tissue exhibited an apparent foreign-body granulomatous inflammatory reaction. This technique could extend the benefits of transthoracic needle biopsy to mechanically ventilated patients, but further studies to prove the safety of isobutyl 2-cyanoacrylate are necessary.


Subject(s)
Biopsy, Needle/methods , Bucrylate , Cyanoacrylates , Lung Diseases/pathology , Animals , Biopsy, Needle/adverse effects , Bucrylate/adverse effects , Cyanoacrylates/adverse effects , Dogs , Foreign-Body Reaction/chemically induced , Hemoptysis/etiology , Hemoptysis/prevention & control , Pilot Projects , Pneumothorax/etiology , Pneumothorax/prevention & control , Positive-Pressure Respiration , Random Allocation
3.
Toxicol Lett ; 27(1-3): 51-7, 1985 Sep.
Article in English | MEDLINE | ID: mdl-4060185

ABSTRACT

Interstitial pulmonary fibrosis (IPF) is often of uncertain etiology and is therefore named 'idiopathic' pulmonary fibrosis. Some occupational exposures, however, are known to cause interstitial fibrosis, asbestos and silica being well-known examples. We present clinical and pathological findings of a case with IPF and the results of microchemical analysis of inorganic particulate matter in the lung tissue. A very high lung burden of inorganic contaminants was found, including silica and metallic compounds. Emphasis is given to the importance of obtaining detailed occupational histories and conducting microchemical analysis of lung tissue in order to clarify etiological factors in cases with 'idiopathic' pulmonary fibrosis.


Subject(s)
Occupational Diseases/etiology , Pulmonary Fibrosis/etiology , Aged , Automobiles , Dust , Environmental Pollutants/analysis , Humans , Lung/analysis , Lung/pathology , Male
4.
Chest ; 85(1): 128-31, 1984 Jan.
Article in English | MEDLINE | ID: mdl-6690240

ABSTRACT

Pulmonary artery rupture by a flow-directed balloon-tipped catheter is a rare complication if guidelines for insertion of catheters are strictly applied. It should be stressed that the need for a "confirmed" wedge pressure should be weighed against the very real risk of this potentially fatal complication. Users of this catheter should expect and anticipate distal migration of the catheter tip. Great care must be exercised in inflating the balloon, particularly when the location of the catheter tip in the pulmonary vascular bed is unknown. Excessive catheter manipulation should be avoided. Hemoptysis, hemothorax, cardiac or respiratory instability in patients who have the PA catheter should be suspected to have this grave complication and appropriate emergency measures should be taken until this complication has been ruled out.


Subject(s)
Cardiac Catheterization/instrumentation , Hemorrhage/etiology , Lung Diseases/etiology , Pulmonary Artery/injuries , Aged , Cardiac Catheterization/adverse effects , Female , Hemoptysis/etiology , Hemothorax/etiology , Humans , Rupture
SELECTION OF CITATIONS
SEARCH DETAIL
...