Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Part Fibre Toxicol ; 13(1): 34, 2016 06 21.
Article in English | MEDLINE | ID: mdl-27328692

ABSTRACT

BACKGROUND: Graphene, a monolayer of carbon, is an engineered nanomaterial (ENM) with physical and chemical properties that may offer application advantages over other carbonaceous ENMs, such as carbon nanotubes (CNT). The goal of this study was to comparatively assess pulmonary and systemic toxicity of graphite nanoplates, a member of the graphene-based nanomaterial family, with respect to nanoplate size. METHODS: Three sizes of graphite nanoplates [20 µm lateral (Gr20), 5 µm lateral (Gr5), and <2 µm lateral (Gr1)] ranging from 8-25 nm in thickness were characterized for difference in surface area, structure,, zeta potential, and agglomeration in dispersion medium, the vehicle for in vivo studies. Mice were exposed by pharyngeal aspiration to these 3 sizes of graphite nanoplates at doses of 4 or 40 µg/mouse, or to carbon black (CB) as a carbonaceous control material. At 4 h, 1 day, 7 days, 1 month, and 2 months post-exposure, bronchoalveolar lavage was performed to collect fluid and cells for analysis of lung injury and inflammation. Particle clearance, histopathology and gene expression in lung tissue were evaluated. In addition, protein levels and gene expression were measured in blood, heart, aorta and liver to assess systemic responses. RESULTS: All Gr samples were found to be similarly composed of two graphite structures and agglomerated to varying degrees in DM in proportion to the lateral dimension. Surface area for Gr1 was approximately 7-fold greater than Gr5 and Gr20, but was less reactive reactive per m(2). At the low dose, none of the Gr materials induced toxicity. At the high dose, Gr20 and Gr5 exposure increased indices of lung inflammation and injury in lavage fluid and tissue gene expression to a greater degree and duration than Gr1 and CB. Gr5 and Gr20 showed no or minimal lung epithelial hypertrophy and hyperplasia, and no development of fibrosis by 2 months post-exposure. In addition, the aorta and liver inflammatory and acute phase genes were transiently elevated in Gr5 and Gr20, relative to Gr1. CONCLUSIONS: Pulmonary and systemic toxicity of graphite nanoplates may be dependent on lateral size and/or surface reactivity, with the graphite nanoplates > 5 µm laterally inducing greater toxicity which peaked at the early time points post-exposure relative to the 1-2 µm graphite nanoplate.


Subject(s)
Graphite/toxicity , Lung/drug effects , Nanoparticles , Nanostructures/toxicity , Animals , Bronchoalveolar Lavage Fluid , Lung/metabolism , Mice , Microscopy, Electron, Scanning , RNA, Messenger/metabolism
2.
Chem Res Toxicol ; 27(7): 1176-86, 2014 Jul 21.
Article in English | MEDLINE | ID: mdl-24921151

ABSTRACT

Z-DNA is the only DNA conformation that has a left-handed helical twist. Although Z-DNA has been implicated in both carcinogenesis and mutagenesis, its specific biological role remains uncertain. We have demonstrated that the formation of C8-arylguanine DNA adducts, derived from arylhydrazines, shifts the B/Z-DNA equilibrium toward the Z-DNA conformation in d(CG)5 sequences. However, our previous work examined the effect of two adducts in the duplex, and it was unclear whether the two base modifications were working together to cause the equilibrium shift toward the Z-DNA conformation. Here we report the synthesis and characterization of a hairpin oligonucleotide sequence (d(CG)5T4(CG)5) containing only one C8-arylguanine modified base. The unmodified hairpin and the previously studied unmodified double-stranded oligonucleotide were conformationally similar, and each required ∼3 M NaCl to yield a B-/Z-DNA ratio of 1:1. The introduction of a single C8-arylguanine modification significantly reduced the NaCl concentration needed to produce a 1:1 B-/Z-DNA ratio in the hairpin. Further, the addition of MgCl2 and spermine to the C8-arylguanine-modified hairpin shifts the B/Z-DNA equilibrium such that the Z form predominated under physiological conditions. NMR and molecular modeling indicated the conformational effects produced by the C8-arylguanine modification occurred locally at the site of modification while CD data demonstrated that the C8-arylguanine-modified base destabilized the B form. Additionally, our data show that adopting the Z-DNA conformation is preferred over denaturation to the single-stranded form. Finally, the conformational effects of the C8-arylguanine modifications were not additive and the introduction of any such modifications drive Z-DNA formation under physiological conditions, which may provide a novel carcinogenesis mechanism where DNA adducts confer their carcinogenicity through a Z-DNA-mediated mechanism.


Subject(s)
DNA, Z-Form/chemistry , Oligonucleotides/chemistry , DNA, B-Form/chemistry , Guanine/chemistry , Magnetic Resonance Spectroscopy , Models, Molecular , Transition Temperature
3.
Part Fibre Toxicol ; 10(1): 53, 2013 Oct 21.
Article in English | MEDLINE | ID: mdl-24144386

ABSTRACT

BACKGROUND: Dosimetry for toxicology studies involving carbon nanotubes (CNT) is challenging because of a lack of detailed occupational exposure assessments. Therefore, exposure assessment findings, measuring the mass concentration of elemental carbon from personal breathing zone (PBZ) samples, from 8 U.S.-based multi-walled CNT (MWCNT) manufacturers and users were extrapolated to results of an inhalation study in mice. RESULTS: Upon analysis, an inhalable elemental carbon mass concentration arithmetic mean of 10.6 µg/m3 (geometric mean 4.21 µg/m3) was found among workers exposed to MWCNT. The concentration equates to a deposited dose of approximately 4.07 µg/d in a human, equivalent to 2 ng/d in the mouse. For MWCNT inhalation, mice were exposed for 19 d with daily depositions of 1970 ng (equivalent to 1000 d of a human exposure; cumulative 76 yr), 197 ng (100 d; 7.6 yr), and 19.7 ng (10 d; 0.76 yr) and harvested at 0, 3, 28, and 84 d post-exposure to assess pulmonary toxicity. The high dose showed cytotoxicity and inflammation that persisted through 84 d after exposure. The middle dose had no polymorphonuclear cell influx with transient cytotoxicity. The low dose was associated with a low grade inflammatory response measured by changes in mRNA expression. Increased inflammatory proteins were present in the lavage fluid at the high and middle dose through 28 d post-exposure. Pathology, including epithelial hyperplasia and peribronchiolar inflammation, was only noted at the high dose. CONCLUSION: These findings showed a limited pulmonary inflammatory potential of MWCNT at levels corresponding to the average inhalable elemental carbon concentrations observed in U.S.-based CNT facilities and estimates suggest considerable years of exposure are necessary for significant pathology to occur at that level.


Subject(s)
Dose-Response Relationship, Drug , Nanotubes, Carbon , Occupational Exposure , Animals , Humans , Inhalation Exposure , Mice , Microscopy, Electron
SELECTION OF CITATIONS
SEARCH DETAIL
...