Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Case Rep Radiol ; 2014: 215465, 2014.
Article in English | MEDLINE | ID: mdl-24707425

ABSTRACT

Foreign body (FB) ingestion is a common clinical problem and most FBs pass through the gastrointestinal tract without the need for intervention. A wide spectrum of clinical presentations may be possible and these can be either acute or chronic. We present a case of an 83-year-old woman featuring insidious abdominal discomfort who was hospitalized in our institution due to worsening symptoms. She underwent contrast-enhanced computed tomography (CT) evaluation which showed the presence of a significant parietal thickening of the transverse and descending colon, a mesenteric loose tissue imbibition, venous engorgement, and no filling defect of visceral arteries, suggesting a condition of nonocclusive colon ischemia. A hyperdense FB was identified in the sigma and was associated with a small pseudotumoral mass. The patient underwent surgical exploration which confirmed the hypoperfusional state of the colon, showing the presence of a chicken bone perforating the sigma and lying in the context of a pseudotumoral mass. Our experience shows how contrast-enhanced CT is feasible and can be strongly recommended as a first-line imaging tool on suspicion of colon ischemia and also how it can easily identify the underlying cause, in our case a FB sealed perforation of the sigma with pseudotumoral mass formation.

2.
ISRN Radiol ; 2013: 826073, 2013.
Article in English | MEDLINE | ID: mdl-24967278

ABSTRACT

The aim of our study was to compare the results of the TTE (transthoracic echocardiography) with the results obtained by the ECG-gated 64 slices CT during the followup of patients with bicuspid aortic valve (BAV), after aortic valve replacement; in particular we evaluated the aortic root and the ascending aorta looking for a new algorithm in the followup of these patients. From January 1999 to December 2009 our attention was focused on 67 patients with isolated surgical substitution of aortic valve; after dismissal they were strictly observed. During the period between May and September 2010, these patients underwent their last evaluation, and clinical exams, ECG, TTE, and an ECG-gated-MDCT were performed. At followup TTE results showed an aortic root of 36.7 ± 4 mm and an ascending aorta of 39.6 ± 4.8 mm. ECG- gated CT showed an aortic root of 37.9 ± 5.5 mm and an ascending aorta of 43.1 ± 5.2. The comparison between preoperative and postoperative TTE shows a significant long-term dilatation of the ascending aorta while the aortic root diameter seems to be stable. ECG-gated CT confirms the stability of the aortic root diameter (38.2 ± 5.3 mm versus 37.9 ± 5.5 mm; <0.0001) and the increasing diameter value of the ascending aorta (40.2 ± 3.9 mm versus 43.1 ± 5.2 mm; P = 0.0156). Due to the different findings between CT and TTE studies, ECG-gated CT should no longer be considered as a complementary exam in the followup of patients with BAV, but as a fundamental role since it is a real necessity.

SELECTION OF CITATIONS
SEARCH DETAIL
...