Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Publication year range
1.
J Sci Food Agric ; 101(6): 2355-2361, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33006379

ABSTRACT

BACKGROUND: Slightly acidic electrolyzed water (SAEW) has been shown to offer a promising alternative for the inactivation of bacteria on egg surfaces, but the cuticle of the egg is damaged during this disinfection process. However, if SAEW disinfection is followed by chitosan (CS) coating treatment, this will construct a new membrane and prevent the loss of moisture and carbon dioxide through the damaged cuticle. Hence, the objective of this study was to investigate the efficacy of SAEW disinfection followed by CS coating treatment for improving the internal quality of eggs during 6 weeks of storage at 25 °C. RESULTS: Scanning electron microscopy revealed that SAEW-treated eggs had deeper and wider cracks than control eggs stored between 0 and 21 days. Moreover, the depth and width of the cracks in the uncoated eggs increased as storage time increased. However, the CS coating method was successfully used on SAEW-disinfected eggs to construct a barrier against the negative effects of shell damage. After 6 weeks of storage at 25 °C, the yolk index, albumen pH, Haugh unit value and weight loss value of the SAEW + CS group were 0.31%, 9.01%, 63.72% and 5.35%, respectively. CONCLUSIONS: A combination of SAEW and CS was more effective at maintaining internal egg quality than SAEW or CS treatments alone during storage. © 2020 Society of Chemical Industry.


Subject(s)
Chitosan/chemistry , Disinfection/methods , Eggs/analysis , Water/chemistry , Animals , Chickens , Chitosan/pharmacology , Disinfectants/chemistry , Disinfectants/pharmacology , Disinfection/instrumentation , Electrolysis , Hydrogen-Ion Concentration , Water/pharmacology
2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-344222

ABSTRACT

This paper describes a calibration phantom system for QCT bone mineral density determination, which consists of 4-standard-solid-sample calibration phantom, a quality assurance (QA) phantom and the bone mineral density analysis software. The system adds to the new applications of CT systems, and provides a new method with a good accuracy and reliability for the examination, diagnosis, prevention, treatment of osteoporosis diseases and the observation of curative effect of drugs.


Subject(s)
Animals , Humans , Absorptiometry, Photon , Methods , Algorithms , Bone Density , Calibration , Equipment Design , Image Processing, Computer-Assisted , Methods , Imaging, Three-Dimensional , Methods , Osteoporosis , Diagnostic Imaging , Phantoms, Imaging , Software , Tomography, X-Ray Computed , Methods
SELECTION OF CITATIONS
SEARCH DETAIL
...