Turk Kardiyol Dern Ars ; 48(2): 167-170, 2020 03.
Article in English | MEDLINE | ID: mdl-32147646

ABSTRACT

A 32-year-old male patient was admitted to the hospital with syncope. An electrocardiogram revealed complete atrioventricular (AV) block and a right bundle branch block with a QRS duration of 218 milliseconds. The heart rate was 40 beats/minute. Echocardiography revealed that both AV valves opened to a single ventricle as well as noncompaction of the myocardium. Due to New York Heart Association class III heart failure, cardiac resynchronization therapy with a defibrillator device (CRT-D) was performed. After the implantation, the electrocardiography QRS duration was reduced to 183 ms. To our knowledge, this was the first reported case of CRT-D implantation in a patient with a noncompacted single ventricle and complete AV block.


Subject(s)
Atrioventricular Block/diagnosis , Bundle-Branch Block/diagnosis , Cardiomyopathies/diagnosis , Heart Ventricles/abnormalities , Adult , Atrioventricular Block/complications , Atrioventricular Block/therapy , Bundle-Branch Block/complications , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy , Cardiomyopathies/complications , Cardiomyopathies/therapy , Diagnosis, Differential , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/therapy , Humans , Male