1.
Heart Rhythm O2 ; 5(5): 289-293, 2024 May.
Article in English | MEDLINE | ID: mdl-38840769

ABSTRACT

Background: Cardiovascular implantable electronic device (CIED) infections are a common indication for device extraction. Early diagnosis and complete system removal are crucial to reduce morbidity and mortality. The lack of clear infectious symptoms makes the diagnosis of pocket infections challenging and may delay referral for extraction. Objective: We aimed to determine if inflammatory biomarkers can help diagnose CIED isolated pocket infection. Methods: We performed a retrospective analysis of all patients undergoing transvenous lead extraction for CIED infection at the University of California San Diego from 2012 to 2022 (N = 156). Patients were classified as systemic infection (n = 88) or isolated pocket infection (n = 68). Prospectively collected preoperative procalcitonin (PCT), C-reactive protein, and white blood cell count were compared between groups. Results: Pairwise comparisons revealed that the systemic infection group had a higher PCT than the control group (P < .001) and the pocket infection group (P = .009). However, there was no significant difference in PCT value between control subjects and isolated pocket infection subjects. Higher white blood cell count was only associated with systemic infection when compared with our control group (P = .018). Conclusion: In patients diagnosed with CIED infections requiring extraction, inflammatory biomarkers were not elevated in isolated pocket infection. Inflammatory markers are not predictive of the diagnosis of pocket infections, which ultimately requires a high level of clinical suspicion.

2.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749633

ABSTRACT

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Subject(s)
Defibrillators, Implantable , Device Removal , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Device Removal/methods , Defibrillators, Implantable/adverse effects , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/diagnostic imaging , Pacemaker, Artificial/adverse effects , Male , Echocardiography, Transesophageal , Tomography, X-Ray Computed , Aged , Foramen Ovale, Patent/surgery , Foramen Ovale, Patent/diagnostic imaging , Female , Middle Aged
3.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38749619

ABSTRACT

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Severity of Illness Index
4.
Heart Rhythm O2 ; 5(2): 131-136, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38545321

ABSTRACT

Background: Respiratory motion management strategies are used to minimize the effects of breathing on the precision of stereotactic ablative radiotherapy for ventricular tachycardia, but the extent of cardiac contractile motion of the human heart has not been systematically explored. Objective: We aim to assess the magnitude of cardiac contractile motion between different directions and locations in the heart. Methods: Patients with intracardiac leads or valves who underwent 4-dimensional cardiac computed tomography (CT) prior to a catheter ablation procedure for atrial or ventricular arrhythmias at 2 medical centers were studied retrospectively. The displacement of transvenous right atrial appendage, right ventricular (RV) implantable cardioverter-defibrillator, coronary sinus lead tips, and prosthetic cardiac devices across the cardiac cycle were measured in orthogonal 3-dimensional views on a maximal-intensity projection CT reconstruction. Results: A total of 31 preablation cardiac 4-dimensional cardiac CT scans were analyzed. The LV lead tip had significantly greater motion compared with the RV lead in the anterior-posterior direction (6.0 ± 2.2 mm vs 3.8 ± 1.7 mm; P = .01) and superior-inferior direction (4.4 ± 2.9 mm vs 3.5 ± 2.0 mm; P = .049). The prosthetic aortic valves had the least movement of all fiducials, specifically compared with the RV lead tip in the left-right direction (3.2 ± 1.2 mm vs 6.1 ± 3.8 mm, P = .04) and the LV lead tip in the anterior-posterior direction (3.8 ± 1.7 mm vs 6.0 ± 2.2 mm, P = .03). Conclusion: The degree of cardiac contractile motion varies significantly (1 mm to 15.2 mm) across different locations in the heart. The effect of contractile motion on the precision of radiotherapy should be assessed on a patient-specific basis.

5.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38472038

ABSTRACT

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Subject(s)
Cardiovascular Infections , Endocarditis , Humans , Positron Emission Tomography Computed Tomography , Fluorodeoxyglucose F18 , Consensus , Tomography, X-Ray Computed , Multimodal Imaging , Endocarditis/diagnostic imaging , Tomography, Emission-Computed, Single-Photon
7.
Heart Rhythm ; 21(5): e1-e29, 2024 May.
Article in English | MEDLINE | ID: mdl-38466251

ABSTRACT

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Subject(s)
Consensus , Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Radiopharmaceuticals , Humans , Fluorodeoxyglucose F18/pharmacology , Positron Emission Tomography Computed Tomography/methods , Radiopharmaceuticals/pharmacology , Leukocytes , United States , Cardiovascular Infections/diagnosis , Societies, Medical , Multimodal Imaging/methods , Single Photon Emission Computed Tomography Computed Tomography/methods , Endocarditis/diagnosis , Endocarditis/diagnostic imaging
8.
JACC Cardiovasc Imaging ; 17(6): 669-701, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38466252

ABSTRACT

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multisocietal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multifocal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Subject(s)
Consensus , Delphi Technique , Fluorodeoxyglucose F18 , Leukocytes , Positron Emission Tomography Computed Tomography , Predictive Value of Tests , Radiopharmaceuticals , Single Photon Emission Computed Tomography Computed Tomography , Humans , Fluorodeoxyglucose F18/administration & dosage , Radiopharmaceuticals/administration & dosage , Positron Emission Tomography Computed Tomography/standards , Single Photon Emission Computed Tomography Computed Tomography/standards , Prognosis , Prosthesis-Related Infections/diagnostic imaging , Reproducibility of Results , Endocarditis/diagnostic imaging , Cardiovascular Infections/diagnostic imaging , Algorithms
9.
Clin Infect Dis ; 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38466039

ABSTRACT

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

13.
J Cardiovasc Electrophysiol ; 35(2): 240-246, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38047465

ABSTRACT

INTRODUCTION: The pivotal study of the extravascular implantable cardioverter-defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient-reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. METHODS: The EV ICD Pivotal Study was a prospective, single-arm, nonrandomized, global, premarket approval trial. Patients completed the 12-Item Short Form Survey (SF-12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. RESULTS: From baseline to 6 months, patients within the EV ICD Pivotal Study (n = 247) reported statistically significant SF-12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV-ICD or S-ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S-ICD and 73.0 ± 17.4, p = .004 for TV-ICD). CONCLUSION: The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6-month follow-up and markedly better overall acceptance of their ICD compared to a previous study with S-ICD and TV-ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.


Subject(s)
Defibrillators, Implantable , Humans , Quality of Life , Prospective Studies , Surveys and Questionnaires , Patient Reported Outcome Measures
14.
J Cardiovasc Electrophysiol ; 35(2): 230-237, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38047467

ABSTRACT

INTRODUCTION: The extravascular implantable cardioverter defibrillator (EV ICD) has extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries. METHODS: Battery longevity data were modeled using a Markov model from averages reported in device labeling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. RESULTS: Average modeled battery longevity was determined to be 7.3 years for the S-ICD versus 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to S-ICD and a 24.3%-26.0% reduction in cost. A one-way sensitivity analysis of the model for the US healthcare system found that use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with five-figure cost savings in all scenarios ($18 602-$40 948). CONCLUSION: The longer projected battery life of the EV ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.


Subject(s)
Defibrillators, Implantable , Humans , Equipment Failure , Electric Countershock/adverse effects , Forecasting , Cost Savings
16.
J Interv Card Electrophysiol ; 67(3): 639-648, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37855992

ABSTRACT

BACKGROUND: Pulsed field ablation (PFA) induces cell death through electroporation using ultrarapid electrical pulses. We sought to compare the procedural efficiency characteristics, safety, and efficacy of ablation of atrial fibrillation (AF) using PFA compared with thermal energy ablation. METHODS: We performed an extensive literature search and systematic review of studies that compared ablation of AF with PFA versus thermal energy sources. Risk ratio (RR) 95% confidence intervals (CI) were measured for dichotomous variables and mean difference (MD) 95% CI were measured for continuous variables, where RR < 1 and MD < 0 favor the PFA group. RESULTS: We included 6 comparative studies for a total of 1012 patients who underwent ablation of AF: 43.6% with PFA (n = 441) and 56.4% (n = 571) with thermal energy sources. There were significantly shorter procedures times with PFA despite a protocolized 20-min dwell time (MD - 21.95, 95% CI - 33.77, - 10.14, p = 0.0003), but with significantly longer fluroscopy time (MD 5.71, 95% CI 1.13, 10.30, p = 0.01). There were no statistically significant differences in periprocedural complications (RR 1.20, 95% CI 0.59-2.44) or recurrence of atrial tachyarrhythmias (RR 0.64, 95% CI 0.31, 1.34) between the PFA and thermal ablation cohorts. CONCLUSIONS: Based on the results of this meta-analysis, PFA was associated with shorter procedural times and longer fluoroscopy times, but no difference in periprocedural complications or rates of recurrent AF when compared to ablation with thermal energy sources. However, larger randomized control trials are needed.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria/surgery , Treatment Outcome , Pulmonary Veins/surgery
17.
Heart Rhythm O2 ; 4(10): 599-608, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37936671

ABSTRACT

Background: Pulsed field ablation (PFA) has emerged as a novel energy source for the ablation of atrial fibrillation (AF) using ultrarapid electrical pulses to induce cell death via electroporation. Objective: The purpose of this study was to compare the safety and acute efficacy of ablation for AF with PFA vs thermal energy sources. Methods: We performed an extensive literature search and systematic review of studies that evaluated the safety and efficacy of ablation for AF with PFA and compared them to landmark clinical trials for ablation of AF with thermal energy sources. Freeman-Tukey double arcsine transformation was used to establish variance of raw proportions followed by the inverse with the random-effects model to combine the transformed proportions and generate the pooled prevalence and 95% confidence interval (CI). Results: We included 24 studies for a total of 5203 patients who underwent AF ablation. Among these patients, 54.6% (n = 2842) underwent PFA and 45.4% (n = 2361) underwent thermal ablation. There were significantly fewer periprocedural complications in the PFA group (2.05%; 95% CI 0.94-3.46) compared to the thermal ablation group (7.75%; 95% CI 5.40-10.47) (P = .001). When comparing AF recurrence up to 1 year, there was a statistically insignificant trend toward a lower prevalence of recurrence in the PFA group (14.24%; 95% CI 6.97-23.35) compared to the thermal ablation group (25.98%; 95% CI 15.75-37.68) (P = .132). Conclusion: Based on the results of this meta-analysis, PFA was associated with lower rates of periprocedural complications and similar rates of acute procedural success and recurrent AF with up to 1 year of follow-up compared to ablation with thermal energy sources.

18.
J Arrhythm ; 39(5): 681-756, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37799799

ABSTRACT

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.

20.
Heart Rhythm ; 20(9): e17-e91, 2023 09.
Article in English | MEDLINE | ID: mdl-37283271

ABSTRACT

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Child , Humans , Bundle of His , Treatment Outcome , Cardiac Conduction System Disease , Cardiac Resynchronization Therapy/methods , Heart Failure/therapy , Electrocardiography/methods
SELECTION OF CITATIONS