Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Curr Med Imaging ; 18(5): 509-531, 2022.
Article in English | MEDLINE | ID: mdl-34503420

ABSTRACT

BACKGROUND: Electroencephalographic (EEG) recordings are used to trace neural activity within the cortex to study brain functioning over time. INTRODUCTION: During data acquisition, the unequivocal way to reduce artifact is to avoid artifact stimulating events. Though there are certain artifacts that make this task challenging due to their association with the internal human mechanism, in the human-computer interface, these physiological artifacts are of great assistance and act as a command signal for controlling a device or an application (communication). That is why pre-processing of electroencephalographic readings has been a progressive area of exploration, as none of the published work can be viewed as a benchmark for constructive artifact handling. METHODS: This review offers a comprehensive insight into state of the art physiological artifact removal techniques listed so far. The study commences from the single-stage traditional techniques to the multistage techniques, examining the pros and cons of each discussed technique. Also, this review paper gives a general idea of various datasets available and briefs the topical trend in EEG signal processing. RESULTS: Comparing the state of the art techniques with hybrid ones on the basis of performance and computational complexity, it has been observed that the single-channel techniques save computational time but lack in effective artifact removal especially physiological artifacts. On the other hand, hybrid techniques merge the essential characteristics resulting in increased performance, but time consumption and complexity remain an issue. CONCLUSION: Considering the high probability of the presence of multiple artifacts in EEG channels, a trade-off between performance, time and computational complexity is the only key for effective processing of artifacts in the time ahead. This paper is anticipated to facilitate upcoming researchers in enriching the contemporary artifact handling techniques to mitigate the expert's burden.


Subject(s)
Algorithms , Artifacts , Electroencephalography/methods , Humans , Signal Processing, Computer-Assisted
2.
Biomed Mater Eng ; 29(1): 53-65, 2018.
Article in English | MEDLINE | ID: mdl-29254073

ABSTRACT

BACKGROUND: WPS is a non-invasive method to investigate human health. During signal acquisition, noises are also recorded along with WPS. OBJECTIVE: Clean WPS with high peak signal to noise ratio is a prerequisite before use in disease diagnosis. Wavelet Transform is a commonly used method in the filtration process. Apart from its extensive use, the appropriate factors for wavelet denoising algorithm is not yet clear in WPS application. The presented work gives an effective approach to select various factors for wavelet denoise algorithm. With the appropriate selection of wavelet and factors, it is possible to reduce noise in WPS. METHODS: In this work, all the factors of wavelet denoising are varied successively. Various evaluation parameters such as MSE, PSNR, PRD and Fit Coefficient are used to find out the performance of the wavelet denoised algorithm at every one step. RESULTS: The results obtained from computerized WPS illustrates that the presented approach can successfully select the mother wavelet and other factors for wavelet denoise algorithm. The selection of db9 as mother wavelet with sure threshold function and single rescaling function using UWT has been a better option for our database. CONCLUSION: The empirical results proves that the methodology discussed here could be effective in denoising WPS of any morphological pattern.


Subject(s)
Algorithms , Heart Rate , Wavelet Analysis , Wrist/physiology , Equipment Design , Humans , Signal Processing, Computer-Assisted/instrumentation , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...