1.
J Knee Surg ; 36(4): 417-423, 2023 Mar.
Article in English | MEDLINE | ID: mdl-34507360

ABSTRACT

Cemented unicompartmental knee arthroplasty (UKA) shows good survivorship and function. However, implant failure, causing the need for revision, can occur. Aseptic loosening is still among the most common reasons for revision. The purpose of this study was to assess the influence of preimplantation lavage technique on tibial cement penetration depth, tibial cement volume, and load to fracture in the tibial component of mobile-bearing UKA. In 10 pairs of fresh frozen human tibiae, cemented UKA was implanted by an experienced surgeon. Tibial components were then implanted, left and right tibiae were randomly allocated to group A or B. Prior to implantation, irrigation was performed with either syringe lavage or pulsatile jet lavage in a standardized manner. Cement surface was 4170.2 mm2 (3271.6-5497.8 mm2) in the syringe lavage group, whereas the jet lavage group showed 4499.3 mm2 (3354.3-5809.1 mm2); cement volume was significantly higher as well (4143.4 mm3 (2956.6-6198.6 mm3) compared with 5936.9 mm3 (3077.5-8183.1 mm3)). Cement penetration depth was 2.5 mm (1.7-3.2 mm) for the jet lavage, and 1.8 mm (1.2-2.4 mm) for the syringe lavage. The mean fracture load was 4680 N in the jet lavage group and 3800 N in the syringe lavage group (p = 0.001). Subsidence was significantly higher for syringe lavage. This study suggests a correlation of cement penetration depth and cement volume to implant failure in the tibial component of a UKA using a cadaveric model. The type of bone lavage most likely influences these two key parameters.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Arthroplasty, Replacement, Knee/methods , Bone Cements , Cadaver , Cementation/methods , Therapeutic Irrigation/methods , Tibia/surgery
2.
Bone Joint Res ; 11(4): 229-238, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35400170

ABSTRACT

AIMS: One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. METHODS: A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). RESULTS: The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. CONCLUSION: From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229-238.

3.
Bone Joint Res ; 11(2): 82-90, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35124977

ABSTRACT

AIMS: The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. METHODS: Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system. RESULTS: At the main fixation zone, the twin peg shows less relative movement at 70°/115°. At the transition zone, relative movements are smaller for the single peg for both angles. The single peg shows higher compression at 70° flexion, whereas the twin peg design shows higher compression at 115°. X-displacement is significantly higher for the single peg at 115°. CONCLUSION: Bony defects should be avoided in OUKA. The twin peg shows high resilience against push-out force and should be preferred over the single peg. Cite this article: Bone Joint Res 2022;11(2):82-90.

4.
Knee ; 33: 185-192, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34638017

ABSTRACT

BACKGROUND: Aseptic loosening remains one of the most common causes of revision of the tibial component for total knee arthroplasty. A stable bond between implant and cement is essential for appropriate long-term results. The aim of our in vitro study was to investigate the maximum failure load of tibial ATTUNE prosthesis design alternatives compared with a previous design. In addition, cement-in-cement revision was considered as a potential strategy after tibial component debonding. METHODS: The experimental investigations of the maximum failure load of the implant-cement interface were performed under optimal conditions, without potential contamination. We compared the designs of the tibial components of the ATTUNE, ATTUNE S+ and P.F.C. Sigma. In addition, we investigated the cement-in-cement revision for the ATTUNE knee system replacing it with an ATTUNE S+. RESULTS: The maximum failure load showed no significant difference between P.F.C. Sigma and ATTUNE groups (P = 0.087), but there was a significant difference between the P.F.C. Sigma and the ATTUNE S+ groups (P < 0.001). The analysis also showed a significant difference (P < 0.001) between the ATTUNE and the ATTUNE S+ groups for the maximum failure load. The ATTUNE S+ cement-in-cement revision group showed a significant higher failure load (P < 0.001) compared with the P.F.C. Sigma and ATTUNE groups. No significant differences (P = 1.000) were found between the ATTUNE S+ cement-in-cement and ATTUNE S+ group. CONCLUSION: Based on these results, we found no design-specific evidence of increased debonding risk with the ATTUNE and ATTUNE S+ components compared with the P.F.C Sigma. Furthermore, the cement-in-cement revision seems to be an alternative for the revision surgery.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Bone Cements , Humans , Knee Joint/surgery , Prosthesis Design , Prosthesis Failure , Reoperation , Tibia/surgery
5.
Knee ; 30: 170-175, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33933907

ABSTRACT

BACKGROUND: Total knee arthroplasty is a very successful standard treatment for severe osteoarthritis. Nevertheless, the literature reports tibial debonding between implant and bone cement as well as radiolucent lines related to the tibial components of different knee systems. Regardless of cementing techniques and the influences during surgery, we examined the design of a newly developed knee system and its predecessors (Attune, Attune S+, P.F.C. Sigma, P.F.C. Sigma RP/M.B.T., all DePuy). METHODS: We investigated the dimensions of the tibial components and the fit between them and their bone bed after instrumentation in a foam material. RESULTS: Our results showed considerable differences for the used knee prostheses as well as their tibial instrumentation options with a corresponding risk for incomplete seating. CONCLUSION: The orthopedic surgeons need to be aware of these design features and the resulting increased seating resistance especially in hard and sclerotic bone. ARTICLE FOCUS: Comparison of the tibial instruments and the different design options of the Attune knee system and its predecessor knee prostheses. KEY MESSAGES: The Attune implant showed incomplete seating because of too much press fit and an uneven bone quality or sclerosis can result in tilting of the tibial component. STRENGTHS AND LIMITATIONS: This is the first study investigating the Attune knee and its predecessor in terms of implant seating and press fit. The foam material is a limitation.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Bone Cements , Knee Prosthesis , Tibia , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Humans , Knee Joint/surgery , Prosthesis Design , Tibia/anatomy & histology , Tibia/surgery
6.
J Clin Med ; 11(1)2021 Dec 24.
Article in English | MEDLINE | ID: mdl-35011832

ABSTRACT

In cemented joint arthroplasty, state-of-the-art cementing techniques include high-pressure pulsatile saline lavage prior to cementation. Even with its outstanding importance in cementation, there are surprisingly few studies regarding the physical parameters that define pulsatile lavage systems. To investigate the parameters of impact pressure, flow rate, frequency and the cleaning effect in cancellous bone, we established a standardized laboratory model. Standardized fat-filled carbon foam specimens representing human cancellous bone were cleaned with three different high-pressure pulsatile lavage systems. Via CT scans before and after cleaning, the cleaning effect was evaluated. All systems showed a cleaning depth of at least 3.0 mm and therefore can be generally recommended to clean cancellous bone in cemented joint arthroplasty. When comparing the three lavage systems, the study showed significant differences regarding cleaning depths and volume, with one system being superior to its peer systems. Regarding the physical parameters, high impact pressure in combination with high flow rate and longer distance to the flushed object seems to be the best combination to improve the cleaning of cancellous bone and therefore increase the chances of a deeper cement penetration that is required in cemented joint arthroplasty. In summary, this study provides the first standardized comparison of different lavage systems and thus gives initial guidance on how to optimally prepare cancellous bone for cemented joint arthroplasty.

7.
Materials (Basel) ; 13(7)2020 Apr 10.
Article in English | MEDLINE | ID: mdl-32290103

ABSTRACT

Adequate primary stability of the acetabular revision construct is necessary for long-term implant survival. The difference in primary stability between tantalum and titanium components is unclear. Six composite hemipelvises with an acetabular defect were implanted with a tantalum augment and cup, using cement fixation between cup and augment. Relative motion was measured at cup/bone, cup/augment and bone/augment interfaces at three load levels; the results were compared to the relative motion measured at the same interfaces of a titanium cup/augment construct of identical dimensions, also implanted into composite bone. The implants showed little relative motion at all load levels between the augment and cup. At the bone/augment and bone/cup interfaces the titanium implants showed less relative motion than tantalum at 30% load (p < 0.001), but more relative motion at 50% (p = n.s.) and 100% (p < 0001) load. The load did not have a significant effect at the augment/cup interface (p = 0.086); it did have a significant effect on relative motion of both implant materials at bone/cup and bone/augment interfaces (p < 0.001). All interfaces of both constructs displayed relative motion that should permit osseointegration. Tantalum, however, may provide a greater degree of primary stability at higher loads than titanium. The clinical implication is yet to be seen.

8.
Materials (Basel) ; 13(7)2020 Mar 26.
Article in English | MEDLINE | ID: mdl-32224971

ABSTRACT

Frequently occurring damage, as well as elevated blood metal ion levels, are reported in relation to a tumor and revision system for total knee arthroplasty (TKA), which applies a rotating hinge coupling with a metal-on-metal (MoM) articulation. As the patient collective for this specific system is small, there is no data on wear generated from the couplings. In this study, wear volume and influencing parameters were investigated at 44 retrieved TKAs with MoM couplings. A scoring system rating frequently occurring abrasive wear between 0 (no wear) and 3 (distinct wear) was established. The wear score was correlated to time in vivo, bone resection length, patient weight and polyethylene inlay damage. Volumetric wear was estimated applying coordinate measurements. An elevated wear score of two or higher was found in 43% of cases. The mean wear rate accounted to 7.8 mm3/year. The main influencing coefficient for the extent of wear is time in vivo. We found a tendency for higher wear scores with higher inlay degradation scores. Patient weight and bone resection length did not impact coupling wear. Assessment of wear damage by a semi-quantitative scoring system has proven to be a reliable option for non-destructive coupling evaluation. The generated wear volume is high.

9.
J Clin Med ; 9(3)2020 Mar 11.
Article in English | MEDLINE | ID: mdl-32168829

ABSTRACT

BACKGROUND: There is little conformity regarding the surgical treatment of metastasis of the proximal femur, especially in palliative patients with limited life expectancy. PATIENTS AND METHODS: En-bloc resection of secondary bone malignancies of the proximal femur and reconstruction by modular arthroplasty was performed in a consecutive series of 45 patients. The mean follow-up period was 16.4 months (0.6-74.7). RESULTS: The survival rate of all patients was 6.6% (95% CI: 0-14.9) at 74.7 months. There was no significant difference in patients with a solitary or disseminated disease at index operation (log-rank p = 0.1214). Recurrent dislocation was the most frequent local complication (n = 6) necessitating an open reduction in four cases. The use of a Trevira tube showed a higher risk of dislocation compared to the simple bonding of remaining soft tissue (6 out of 28 vs. 0 out of 17; Fisher test: p = 0.0463). The worst-case survival rate with the removal of the arthroplasty for any cause and/or loss to follow-up was 80.0% (95% CI: 44.9-100) at 74.7 months (n = 1 due to low-grade infection). CONCLUSIONS: En-bloc resection of metastases and reconstruction by modular arthroplasty is reliable even in patients with very limited life expectancy. Local complications due to tumor growth or instability after intralesional surgery could be managed successfully but recurrent dislocation as the most frequent complication has to be taken into account. The simple bonding of remaining soft tissue around the prosthesis without the use of an attachment tube may reduce the dislocation rate and reoperation risk.

10.
Materials (Basel) ; 13(1)2019 Dec 20.
Article in English | MEDLINE | ID: mdl-31861893

ABSTRACT

Acetabular cup deformation may affect liner/cup congruency, clearance and/or osseointegration. It is unclear, whether deformation of the acetabular components occurs during load and to what extent. To evaluate this, revision multi-hole cups were implanted into six cadaver hemipelvises in two scenarios: without acetabular defect (ND); with a large acetabular defect (LD) that was treated with an augment. In the LD scenario, the cup and augment were attached to the bone and each other with screws. Subsequently, the implanted hemipelvises were loaded under a physiologic partial-weight-bearing modality. The deformation of the acetabular components was determined using a best-fit algorithm. The statistical evaluation involved repeated-measures ANOVA. The mean elastic distension of the ND cup was 292.9 µm (SD 12.2 µm); in the LD scenario, 43.7 µm (SD 11.2 µm); the mean maximal augment distension was 79.6 µm (SD 21.6 µm). A significant difference between the maximal distension of the cups in both scenarios was noted (F(1, 10) = 11.404; p = 0.007). No significant difference was noted between the compression of the ND and LD cups, nor between LD cups and LD augments. The LD cup displayed significantly lower elastic distension than the ND cup, most likely due to increased stiffness from the affixed augment and screw fixation.

11.
Orthop Rev (Pavia) ; 11(3): 8204, 2019 Sep 24.
Article in English | MEDLINE | ID: mdl-31579193

ABSTRACT

Primary total hip arthroplasty (THA) is one of the most successful surgical procedures. Considering the demographic change the use of new ultra-short femoral implants has gained importance especially when treating young patients. Main features are bone conservation, metaphyseal anchoring and thus reducing stress shielding by proximal load transferring. The objective of this study is to give an overview over the subject of femoral neck prostheses. A systematic review was conducted. A total number of 27 publications were taken into this systematic review. Over all, just a few follow-up, biomechanical and radiostereometric studies have been conducted in the past. Still no long-term results (>10 years of follow-up) are available. The available mid-term results indicate unsatisfactory survival rates. Aseptic loosening was the most common reason for revision. Valgus angle and good bone mineral density were considered to be crucial for primary stability of femoral neck prostheses. Register data report a very low percentage of femoral neck prostheses in THA with even more diminishing implantation rates. To conclude, further studies are necessary in order to provide evidence-based recommendations. Currently, due to the inhomogeneous and poor data a reasonable and legitimate recommendation cannot be given.

12.
Int Orthop ; 43(6): 1371-1378, 2019 06.
Article in English | MEDLINE | ID: mdl-30203181

ABSTRACT

PURPOSE: Purpose of the present cohort study was the determination of lower body function and rotation in patients with symptomatic component mal-rotation after total knee arthroplasty using instrumented 3D gait analysis. METHODS: A consecutive series of 12 patients (61.3 years ± 11.4 years) were included suffering under remaining pain or limited range of motion at least six months after total knee arthroplasty. A CT-scan according to the protocol of Berger et al. and instrumented 3D gait analysis were carried out including clinical examination, videotaping, and kinematic analysis using a Plug-in Gait model. Outcome variables were temporospatial parameters as well as kinematics in sagittal and transversal plane. Data for reference group were collected retrospectively and matched by age and gender. RESULTS: Temporospatial parameters of the study group showed decreased velocity, cadence, and step length as well as increased step time. Single limb support was reduced for the affected limb. In sagittal plane, maximum knee flexion during swing phase was reduced for the replaced knee joint. In transverse plane, there was hardly any difference between affected and non-affected limb. Compared to the reference group, both limbs show significant increased internal ankle rotation and external hip rotation. There were significant strong linear correlations between ankle rotation and hip rotation as well as ankle rotation and radiological tibial mal-rotation. CONCLUSIONS: Patients with symptomatic component mal-rotation after total knee arthroplasty showed typically functional deficits. The affected and non-affected limb showed significant increased internal ankle rotation and external hip rotation, while only the affected, replaced knee showed reduced internal knee rotation. Identification of rotational abnormalities of hip and ankle joints seems to be mandatory in TKA to identify the patient group with external hip rotation, internal ankle rotation, and an elevated risk for symptomatic rotational TKA component mal-alignment.


Subject(s)
Gait , Knee Joint/surgery , Aged , Ankle Joint , Arthroplasty, Replacement, Knee , Biomechanical Phenomena , Female , Gait Analysis , Humans , Knee Prosthesis , Male , Middle Aged , Retrospective Studies , Rotation , Tibia/surgery
13.
Knee ; 25(4): 609-616, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29792279

ABSTRACT

BACKGROUND: In uncemented total hip arthroplasty (THA), low bone mineral density (BMD) is associated with aseptic loosening. BMD is usually assessed via dual-energy X-ray absorptiometry (DXA) or quantitative computed tomography, which takes time and exposes patients to radiation. Due to its low risk profile, intraoperative measurement of the trabecular stability might be a useful alternative to DXA. METHODS: In 24 human femora, BMD was analysed using DXA at the femoral necks and the knees. Performing the standard Oxford Unicompartmental Knee Arthroplasty (OUKA) implantation procedure, a wingblade (DensiProbe) coupled to a torque probe was used to evaluate the trabecular peak torque. The standard procedure was modified: before the completion of the central peg drill hole, the DensiProbe was inserted into the pre-drilled hole and then turned until a loss of resistance was achieved. The obtained data was then correlated with BMD at the femoral neck as well as the knee. RESULTS: In all tested regions, a higher peak torque was observed in correlation with a higher BMD. CONCLUSIONS: As demonstrated, the DensiProbe can be a helpful tool to assess the bone quality intraoperatively in OUKA. It can be a valuable decision guidance when faced with choosing between a cemented and a cementless implant. Due to the fact that the central peg hole of the OUKA can be used for the procedure, no additional risk for the patient exists, while the additional work for the surgeon is minimal.


Subject(s)
Absorptiometry, Photon/methods , Arthroplasty, Replacement, Knee/methods , Bone Density/physiology , Knee Joint/surgery , Aged , Aged, 80 and over , Bone Cements , Cadaver , Decision Making , Female , Femur/diagnostic imaging , Femur/surgery , Humans , Knee Prosthesis , Male , Middle Aged , Torque
14.
Clin Biomech (Bristol, Avon) ; 55: 23-27, 2018 06.
Article in English | MEDLINE | ID: mdl-29649670

ABSTRACT

BACKGROUND: The twin peg femoral component was introduced for the cemented Oxford unicondylar knee to increase implant stability. The aim of this experimental study was to investigate the influence of the twin peg design on femoral interface temperature and maximum load to failure in comparison to the single peg design. METHODS: In this experimental study medial Oxford unicompartmental knee arthroplasty was performed in 12 pairs of fresh-frozen human knees. A cemented femoral single peg component was implanted on the one side (group A) and a cemented twin peg component on the other side (group B). Cement interface temperature was continuously monitored during the procedure. Maximum tensile forces of the femoral components were measured by pull-out tests. FINDINGS: Maximum femoral interface temperatures did not reach critical values for heat necrosis of the bone in group A (mean 28.4, SD 1.2 °C) or group B (mean 27.6, SD 0.5 °C). The maximum load to failure was significantly higher in the twin peg group (mean 3628.41, SD 650.92 N) compared to the single peg group (mean 2979, SD 781 N) (P = 0.016). INTERPRETATION: Our experiments showed higher load to failure for the twin peg design compared to the single peg design without raising the risk of heat necrosis at the interfacial bone. The twin peg component offers a save alternative to the single peg component in a cadaveric setting.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Femur/surgery , Knee Prosthesis , Prosthesis Design , Temperature , Aged , Biomechanical Phenomena , Bone Cements , Cadaver , Female , Femur/physiology , Humans , Knee Joint/surgery , Male , Materials Testing , Middle Aged , Osteoarthritis, Knee/surgery , Tensile Strength
15.
J Arthroplasty ; 33(6): 1838-1843, 2018 06.
Article in English | MEDLINE | ID: mdl-29510951

ABSTRACT

BACKGROUND: Revision total hip arthroplasty frequently faces challenges associated with deficient bone stock. Porous metal implants were developed to meet the challenge, but require rapid osseointegration for ultimate success. This study aims to assess relative motion as an indicator for primary stability and osseointegration of two different titanium cups each combined with a titanium augment. METHODS: In 14 cadaver hemipelvises, 2 types of titanium acetabular cups, a traditional sintered-bead cup (POROCOAT Acetabular Cup [PAC]) and a newer porous-coated cup (GRIPTION Acetabular Cup [GAC]) each associated with a porous augment, were subjected to 3-dimensional varying loads, replicating 30% of loads experienced during normal gait. Relative motion was measured at the cup/bone, augment/bone, and cup/augment interfaces. RESULTS: Only at the cup/bone interface was there a statistically significant difference in relative motion between the traditional PAC and the newer GAC, with PAC showing less relative motion (P = .0037). Bone mineral density (BMD) had a significant effect on relative motion (P = .0019) at the cup/bone interface of both cup types, with low BMD specimens showing more relative motion. CONCLUSION: Both cup types combined with augments displayed minimal relative motion that was within the accepted range thought to allow osseointegration, although the traditional surface proved superior to the newer surface. This difference was more pronounced at low BMD, with the well-established PAC cup displaying less relative motion than the more porous GAC cup, consistent with better osseointegration than the more porous cup. This suggests that the more porous implant may be less advantageous than traditional PAC cups, particularly in cases with poorer bone stock.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Osseointegration , Prosthesis Design , Aged , Aged, 80 and over , Bone Density , Humans , Metals , Middle Aged , Porosity , Reoperation , Titanium
16.
J Arthroplasty ; 33(2): 580-585, 2018 02.
Article in English | MEDLINE | ID: mdl-29108792

ABSTRACT

BACKGROUND: The number of revision hip arthroplasty procedures has been increasing substantially, with the acetabular component requiring component revision in over half of the cases. New porous implant designs attempt to improve outcomes due to improved osseointegration; however, sufficient primary stability is paramount for good osseointegration. METHODS: We compared 2 revision cups of the same geometry, yet different surface properties in an in vitro scenario: a porous titanium surface and a conventional sintered-bead titanium surface. These were tested in 10 cadaveric pelvises under a physiologic cyclic partial weight-bearing scenario. Each side was randomly implanted with one of the implants. Relative motion between the bone and cup was measured using an optical measuring device. Statistical evaluation was carried out descriptively using a covariance analysis with repeated measures and a test of fixed effects, with significance determined as P < .05. RESULTS: The conventional cup displayed an average relative motion of 28.02 µm; and the porous implant displayed an average relative motion of 33.42 µm. There was no statistically significant difference between the two with regard to the resultant relative motion (P = .2649). The bone mineral density does have a significant influence on resultant relative motion (P = .0406), with higher bone mineral density correlating with less relative motion in both implants. CONCLUSION: The porous implant provides similar primary stability to the conventional implant in the tested scenario; the motion of both implants relative to the bone was within safe limits for osseointegration. Bone stock must be considered when choosing implant type and postoperative care.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis , Joint Instability/surgery , Osseointegration , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Bone Density , Cadaver , Hip Prosthesis/adverse effects , Humans , Middle Aged , Porosity , Prosthesis Failure , Reoperation
17.
Hip Int ; 27(4): 373-377, 2017 Jul 25.
Article in English | MEDLINE | ID: mdl-28165599

ABSTRACT

INTRODUCTION: Adverse reactions to metal debris often indicate revision surgery in metal-on-metal (MoM) hip arthroplasty and an exchange of the MoM bearing into either a metal on polyethylene or a ceramic-on-polyethylene articulation. At the moment the removal of the entire implant system is the most reasonable method. In order to avoid bone loss caused by the removal of a well-fixed acetabular component, the purpose of this study was to measure the stability of a cemented polyethylene (PE) cup in an acetabular hip resurfacing component and to examine if such a method could be suitable for clinical use. METHODS: PE cups were cemented into 2 different hip resurfacing components and biomechanical tests were applied to measure failure torques under lever out and rotational load. RESULTS: In all cases failure of the interface between the resurfacing components and the cement layer occurred at a very low load (0.14 Nm-61.50 Nm). DISCUSSION: The early failure occurred due to lacking interdigitation of cement and the polished metal surface. Thus we warn against cementing a PE cup into acetabular hip resurfacing components for clinical use.


Subject(s)
Metal-on-Metal Joint Prostheses/adverse effects , Polyethylene/chemistry , Prosthesis Design/methods , Prosthesis Failure , Acetabulum/surgery , Bone Cements , Cementation , Equipment Failure Analysis , Humans , Risk Assessment , Stress, Mechanical
19.
Biomed Res Int ; 2016: 5496396, 2016.
Article in English | MEDLINE | ID: mdl-27660758

ABSTRACT

A retrieval analysis has been performed on 50 polyethylene inlays of cementless screw ring implants (Mecring, Mecron, Berlin, Germany) to investigate the failure mechanism of this specific open cup hip arthroplasty design that has shown a high clinical failure rate. Design-specific damage modes like rim creep, collar fatigue, and backside wear were assessed. Furthermore, the inlays were measured using a CMM to determine deformation. In 90% backside wear was observed and collar fatigue occurred in 68% of the cases. Rim creep was present in 38% of the polyethylene inlays. In 90% of the cases the cup opening diameter was 32.1 mm or less and 46% had a diameter less than 32 mm. It seems that creep and deformation of the polyethylene leads to a reduced diameter at the cup opening and consequently decreased clearance. To avoid this type of failure, polyethylene inlays should be supported at the back by the cup to reduce the risk of ongoing creep deformation.