Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-37872056

ABSTRACT

This report describes a rare case of complete transection of the inferior rectus resulting from blunt trauma to the orbit. Only eight other cases were identified in the literature. Computed tomography scans should be examined carefully for potential extraocular muscle injury.

2.
J Prosthodont ; 2023 Sep 10.
Article in English | MEDLINE | ID: mdl-37691179

ABSTRACT

PURPOSE: When planning guided implant surgery, highly radiopaque materials such as metals or zirconia produce streaking artifacts ('metal artifact') on cone-beam computed tomography scans, which can impair registration of the intraoral scan. This study aimed to determine the effect of metal artifact reduction on the trueness of registration in the presence of multiple full-coverage zirconia crowns. MATERIALS AND METHODS: A 3D-printed maxillary study model was restored with 12 full-coverage zirconia crowns and scanned with an intraoral scanner. Cone-beam computed tomography scans of the study model were acquired, with and without activation of the metal artifact reduction algorithm. Registration of the optical scans was performed using initial point-based registration with surface-based refinement, and the deviation was measured at four pre-defined dental landmarks. Welch's t-test was used to compare the registration error for the metal artifact reduction group with the control group. RESULTS: The average registration error was 0.519 mm (95% CI 0.507 to 0.531) with metal artifact reduction deactivated, compared to 0.478 mm (95% CI 0.460 to 0.496) without metal artifact reduction. Therefore, activation of the metal artifact reduction algorithm was associated with a 0.041 mm (95% CI 0.020 to 0.061, p < 0.001) increase in average registration error. CONCLUSIONS: The use of the metal artifact reduction algorithm slightly reduced trueness in this in vitro study. Clinicians are advised not to rely on a metal artifact reduction (MAR) algorithm for registration of a cone-beam computed tomography scan with an intraoral scan when planning guided implant surgery in the presence of restoration artifacts.

3.
Clin Oral Implants Res ; 34(11): 1257-1266, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37602506

ABSTRACT

OBJECTIVES: To determine the effect of restoration artifact ('metal artifact') on registration accuracy of an intraoral scan and cone-beam computed tomography (CBCT) scan, comparing fiducial marker-based registration with markerless registration. MATERIALS AND METHODS: A maxillary model was fitted with multiple configurations of zirconia crowns to simulate various states of oral rehabilitation. Intraoral scans and CBCT scans (half and full rotation) were acquired. Registration was performed using markerless (point-based registration with surface-based refinement) and fiducial marker-based registration. Each experimental condition was repeated 10 times (n = 320). The absolute deviation was measured at the canines and first molars, and the average and maximum values were analysed using multiple linear regression. RESULTS: R2 was 0.874 for average error and 0.858 for maximum error. For markerless registration, there were 0.041 mm (p < .001) and 0.045 mm (p < .001) increases in average and maximum error per crown, respectively. For fiducial marker-based registration, the effect of additional crowns was not statistically significant for average (p = .067) or maximum (p = .438) error. For a full arch of crowns, the regression model predicted average and maximum errors of 0.581 and 0.697 mm for the markerless technique, and 0.185 and 0.210 mm for the fiducial marker-based technique. Overall, the fiducial marker-based technique was more accurate for four or more crowns. The half rotation scan increased average error by 0.021 mm (p = .001) and maximum error by 0.029 mm (p < .001). CONCLUSIONS: Under the present study's experimental conditions, the fiducial marker-based technique should be considered if four or more full-coverage highly radiopaque restorations are present.


Subject(s)
Artifacts , Fiducial Markers , Cone-Beam Computed Tomography/methods , Crowns
SELECTION OF CITATIONS
SEARCH DETAIL
...