Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
J Med Invest ; 65(1.2): 85-89, 2018.
Article in English | MEDLINE | ID: mdl-29593200

ABSTRACT

Ligamentum flavum (LF) hypertrophy is one of the main factors of lumbar spinal canal stenosis (LSCS). The primary object of this study is to clarify the existence of epiligament in the LF and its role in hypertrophy, and to develop an LF hypertrophy animal model. A cadaveric spine from a 30-year-old man was used to investigate the existence of epiligament in LF. Five LF samples from LSCS patients were obtained to evaluate hypertrophied LF. To create a rat model, we destabilized the lumbar spine. Each LF was sagittally cut for histological evaluation. The epiligament was clearly evident in normal LF specimens, which stained pink on Elastica van Gieson and green on Masson Trichrome. One layer was observed on the dural side and another on the dorsal side of the LF. LSCS patients had an enlarged dorsal epiligament, at around 30 times that of the regular thin epiligament on the dural side. The destabilized rat model showed an enlarged dorsal epiligament, with a mean thickness 8-fold that of the control. LF hypertrophy may be due to enlargement of the dorsal epiligament. Mechanical loading of the LF is an important factor for inducing hypertrophy in the rat model. J. Med. Invest. 65:85-89, February, 2018.


Subject(s)
Ligamentum Flavum/pathology , Lumbar Vertebrae/pathology , Spinal Canal/pathology , Spinal Stenosis/pathology , Adult , Animals , Female , Humans , Hypertrophy , Male , Pilot Projects , Rats , Rats, Wistar
2.
Eur Spine J ; 21 Suppl 5: S653-62, 2012 Jun.
Article in English | MEDLINE | ID: mdl-19936805

ABSTRACT

Various ball and socket-type designs of cervical artificial discs are in use or under investigation. Many artificial disc designs claim to restore the normal kinematics of the cervical spine. What differentiates one type of design from another design is currently not well understood. In this study, authors examined various clinically relevant parameters using a finite element model of C3-C7 cervical spine to study the effects of variations of ball and socket disc designs. Four variations of ball and socket-type artificial disc were placed at the C5-C6 level in an experimentally validated finite element model. Biomechanical effects of the shape (oval vs. spherical ball) and location (inferior vs. superior ball) were studied in detail. Range of motion, facet loading, implant stresses and capsule ligament strains were computed to investigate the influence of disc designs on resulting biomechanics. Motions at the implant level tended to increase following disc replacement. No major kinematic differences were observed among the disc designs tested. However, implant stresses were substantially higher in the spherical designs when compared to the oval designs. For both spherical and oval designs, the facet loads were lower for the designs with an inferior ball component. The capsule ligament strains were lower for the oval design with an inferior ball component. Overall, the oval design with an inferior ball component, produced motion, facet loads, implant stresses and capsule ligament strains closest to the intact spine, which may be key to long-term implant survival.


Subject(s)
Cervical Vertebrae/physiology , Cervical Vertebrae/surgery , Finite Element Analysis , Models, Biological , Prosthesis Design/methods , Total Disc Replacement/methods , Biomechanical Phenomena/physiology , Computer Simulation , Humans , Intervertebral Disc/physiology , Intervertebral Disc/surgery , Ligamentum Flavum/physiology , Longitudinal Ligaments/physiology , Range of Motion, Articular/physiology , Stress, Mechanical , Weight-Bearing/physiology
3.
Clin Biomech (Bristol, Avon) ; 27(3): 226-33, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22019300

ABSTRACT

BACKGROUND: Studies delineating the adjacent level effect of single level disc replacement systems have been reported in literature. The aim of this study was to compare the adjacent level biomechanics of bi-level disc replacement, bi-level fusion and a construct having adjoining level disc replacement and fusion system. METHODS: In total, biomechanics of four models- intact, bi level disc replacement, bi level fusion and fusion plus disc replacement at adjoining levels- was studied to gain insight into the effects of various instrumentation systems on cranial and caudal adjacent levels using finite element analysis (73.6N+varying moment). FINDINGS: The bi-level fusion models are more than twice as stiff as compared to the intact model during flexion-extension, lateral bending and axial rotation. Bi-level disc replacement model required moments lower than intact model (1.5Nm). Fusion plus disc replacement model required moment 10-25% more than intact model, except in extension. Adjacent level motions, facet loads and endplate stresses increased substantially in the bi-level fusion model. On the other hand, adjacent level motions, facet loads and endplate stresses were similar to intact for the bi-level disc replacement model. For the fusion plus disc replacement model, adjacent level motions, facet loads and endplate stresses were closer to intact model rather than the bi-level fusion model, except in extension. INTERPRETATION: Based on our finite element analysis, fusion plus disc replacement procedure has less severe biomechanical effects on adjacent levels when compared to bi-level fusion procedure. Bi-level disc replacement procedure did not have any adverse mechanical effects on adjacent levels.


Subject(s)
Cervical Vertebrae/physiopathology , Intervertebral Disc Degeneration/physiopathology , Intervertebral Disc Degeneration/surgery , Intervertebral Disc/physiopathology , Models, Biological , Prostheses and Implants , Spinal Fusion/methods , Cervical Vertebrae/surgery , Combined Modality Therapy , Compressive Strength , Computer Simulation , Finite Element Analysis , Humans , Intervertebral Disc/surgery , Range of Motion, Articular
4.
Arch Orthop Trauma Surg ; 131(9): 1187-94, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21221610

ABSTRACT

AIM: Rounding surface of the sacral dome and wedging deformity of the vertebral body are commonly observed in patients with isthmic spondylolisthesis. Recently, an animal study showed that the deformity can be caused by the growth plate involvement in the immature pediatric vertebral body after biomechanical alteration due to the pars defects. However, the pathomechanism and biomechanics of these deformities have yet to be clarified. To demonstrate that the sacral rounding deformity observed in pediatric patients with spondylolisthesis can be reversed, and to understand the pathomechanism of the deformity from the biomechanical standpoint by analyzing changes of stress around the growth plate of the vertebral body due to spondylolysis. METHOD: Three-dimensional finite element pediatric lumbar models of the L3-L5 segment were utilized. Unlike the adult model, this pediatric model had growth plates and apophyseal rings. We analyzed stress distribution in response to 351°N axial compression and 10 N m moment in flexion, extension, lateral bending, and axial rotation. Bilateral spondylolysis was created in the model at the L4 level. The stress in the bilateral defect model was compared to the intact model predictions and the results obtained in the pediatric patients with sacral rounding deformity. RESULTS: Two patients presented rounding deformity of the anterior upper corner at S1 at the initial visit. They were asked to stop sports activities and use a soft trunk brace. Twelve months later, no rounding deformity was observed on the radiographs indicating that this deformity was reversible in pediatric cases. The biomechanical study indicated that in the pediatric spondylolytic spine, mechanical stress increased at the anterior upper corner during lumbar motion. CONCLUSION: In the presence of spondylolysis, mechanical stress increases in the growth plate at the anterior upper corner. Repetitive increases of mechanical stress may cause rounding deformity of the sacral dome mediated by growth plate involvement. When mechanical stress at the growth plate is reduced by wearing a brace, the proper functioning of the growth plate can help to remodel the sacral dome to its normal shape.


Subject(s)
Lumbar Vertebrae/physiopathology , Spondylolisthesis/physiopathology , Biomechanical Phenomena , Braces , Child , Female , Growth Plate/physiopathology , Humans , Lumbar Vertebrae/pathology , Male , Models, Anatomic , Spondylolisthesis/etiology , Spondylolisthesis/pathology , Spondylolisthesis/therapy , Sports , Stress, Mechanical
5.
J Spinal Disord Tech ; 23(3): 157-61, 2010 May.
Article in English | MEDLINE | ID: mdl-20072034

ABSTRACT

STUDY DESIGN/SETTING: Retrospective review of clinical outcomes after anterior cervical discectomy and fusion (ACDF) surgery with allograft and plating in patients over 55 years of age. OBJECTIVE: To evaluate the results of ACDF surgery in patients aged 55 years and older. SUMMARY OF BACKGROUND DATA: ACDF surgery has been a standard treatment for cervical degenerative and herniated disc disease for many years. Previous assessments of efficacy have used patient perceived outcome measures including the Neck Disability Index (NDI) and the Short Form 36 Question Health Questionnaire (SF-36). Patient perceived outcome after ACDF surgery in an age-specific cohort (55 y and older) has not been documented previously. METHODS: Fifty-two consecutive patients over 55 years of age who underwent 1 to 3 level ACDF with allograft and plating were identified. Patient perceived outcome questionnaires (NDI and SF-36) were available for 44 patients. There were 28 females and 16 males. Mean age at time of surgery was 61.8 years. Average length of follow-up was 25.2 months (12 to 54 mo). RESULTS: All but one patient demonstrated radiographic healing of the fusion site at the time of their last follow-up. The mean improvement of these 10 groups (total NDI score) was statistically significant (difference =-9.47, t=5.6390, P=1.5198E-06). There was a statistically significant decrease in disability in 7 of the 8 SF-36 categories as well. The mean of the 8 SF-36 categories (total SF-36) improved significantly (improvement=11.92, t=-3.6857, P=0.0007). CONCLUSIONS: On the basis of our statistically significant improvement in NDI and SF-36 scores, as a measure of patient perceived outcome after ACDF surgery, outcomes after ACDF surgery in patients over 55 years of age are not significantly different than those of a younger patient population.


Subject(s)
Cervical Vertebrae/surgery , Diskectomy/methods , Intervertebral Disc Degeneration/surgery , Patient Satisfaction , Spinal Fusion/methods , Age Factors , Aged , Female , Humans , Male , Middle Aged , Patient Selection , Retrospective Studies , Surveys and Questionnaires , Treatment Outcome
6.
Arch Orthop Trauma Surg ; 129(4): 559-67, 2009 Apr.
Article in English | MEDLINE | ID: mdl-18437403

ABSTRACT

STUDY DESIGN: A case report and a biomechanical study using a finite element method. OBJECTIVES: To report a case with the cervical spondylolysis and to understand the biomechanics of the cervical spine with spondylolysis at C6. Cervical spondylolysis, although not a common spinal disorder, can occur in athletes. Presently, the exact pathology, natural history and biomechanics are not known. Thus, treatment strategies for this disorder in athletes are in controversy. To treat and/or advise patients with cervical spondylolysis, the cervical spine biomechanics regarding this disorder should be understood. METHODS: A case of a 12-year-old male judo player is presented. The patient presented with occipital and upper neck pain. Plain radiographs, reconstructed CT scan and MRIs of this patient were reviewed. Biomechanically, stress distributions were analyzed in response to 73.6 N axial compression and 1.5-Nm moment in flexion, extension, lateral bending, and axial rotation using a FE model of the intact ligamentous C3 to C7 segment. Bilateral spondylolysis was created in the model at C6. The stress results from the bilateral defect model were compared to the intact model predictions. RESULTS: Plain radiographs showed bilateral C6 spondylolysis, and grade I spondylolisthesis. MRI showed mild disc degeneration at C6/7. With conservative treatment, the symptoms disappeared. In the spondylolysis model, the maximum Von Mises Stresses at C6/7 increased in all cervical spine motions, as compared to the intact case. Specifically, in axial rotation, the stress increase was 3.7-fold as compared to the intact model. The range of motion at C6/7 increased in the spondylolysis model as well. Again, during axial rotation, the increase in motion was 2.3-fold when compared to the intact model. CONCLUSIONS: Cervical spondylolysis can cause biomechanical alterations, especially in axial rotation, leading to increased disc stresses and range of motion. The increased stresses in the disc and the hypermobility would be a dangerous condition for athletes participating in contact sports such as judo. Thus, we recommended that judo players with cervical spondylolysis should change to non-contact sports, such as jogging.


Subject(s)
Cervical Vertebrae/physiopathology , Martial Arts , Spondylosis/physiopathology , Biomechanical Phenomena , Cervical Vertebrae/diagnostic imaging , Child , Finite Element Analysis , Humans , Male , Range of Motion, Articular , Spondylosis/diagnostic imaging , Tomography, X-Ray Computed
7.
Arch Orthop Trauma Surg ; 129(10): 1433-9, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19084979

ABSTRACT

STUDY DESIGN: Case series and a biomechanical study using a finite element (FE) analysis. OBJECTIVES: To report three cases with multi-level spondylolysis and to understand the mechanism biomechanically. BACKGROUND: Multi-level spondylolysis is a very rare condition. There have been few reports in the literature on multi-level spondylolysis among sports players. METHODS: We reviewed three cases of the condition, clinically. These patients were very active young sports players and had newly developed fresh L4 spondylolysis and pre-existing L5 terminal stage spondylolysis. Thus, we assumed that L5 spondylolysis may have increased the pars stress at the cranial adjacent levels, leading to newly developed spondylolysis at these levels. Biomechanically, we investigated pars stress at L4 with or without spondylolysis at L5 using the finite element technique. RESULTS: L4 pars stress decreased in the presence of L5 spondylolysis, which does not support our first hypothesis. CONCLUSIONS: It seems that multi-level spondylolysis may occur due to genetic and not biomechanical reasons.


Subject(s)
Lumbar Vertebrae/pathology , Spondylolysis/pathology , Adolescent , Athletic Injuries/diagnostic imaging , Athletic Injuries/pathology , Biomechanical Phenomena , Child , Finite Element Analysis , Humans , Lumbar Vertebrae/diagnostic imaging , Male , Spondylolysis/diagnostic imaging , Spondylolysis/genetics , Spondylolysis/therapy , Tomography, X-Ray Computed
9.
Clin Biomech (Bristol, Avon) ; 22(10): 1063-7, 2007 Dec.
Article in English | MEDLINE | ID: mdl-17897759

ABSTRACT

BACKGROUND: Apophyseal ring fracture is one of the important pathologies causing low back pain in children and adolescents. Most of the patients are reported to be in the ossification stage of the ring during growth period rather than early cartilaginous ring stage. There is no previous study clarifying the mechanism of the high prevalence of this disorder in the ossification stage. Thus, in this study, we investigated the effects of ossification of the ring on lumbar spine biomechanics. METHODS: Two three-dimensional finite element pediatric lumbar models were created and analyzed. One model had ossified apophyseal rings and the other one had cartilaginous apophyseal rings. To simulate standing posture, 341N axial compression was applied. Then, 10Nm moment was applied to the model in the six directions of lumbar motion: flexion, extension, lateral bending and axial rotation. Maximum Von Mises stresses in the apophyseal ring were calculated and compared between the two models. FINDINGS: The maximum stresses were always higher in the bony ring in all lumbar motion at all lumbar levels compared to the cartilaginous ring. The stresses at L4 caudal apophyseal ring in extension were 2.60 and 0.68 (MPa) for bony and cartilaginous rings respectively. In flexion, stresses were 3.95 and 1.49 (MPa), in lateral bending, stresses were 6.75 and 2.66 (MPa), and in axial rotation, stresses were reported to be 3.15 and 1.72 (MPa). Thus, the bony ring was stressed by at least 2-fold more than the cartilaginous ring. INTERPRETATION: Apophyseal ring has at least two times more stresses in the ossified stage when compared to the cartilaginous stage resulting in frequent fractures at the interface of bone and cartilage.


Subject(s)
Biomechanical Phenomena/methods , Fractures, Bone/therapy , Adolescent , Bone and Bones/pathology , Cartilage/pathology , Child, Preschool , Humans , Lumbar Vertebrae/pathology , Models, Anatomic , Models, Theoretical , Osteogenesis , Spinal Fractures/pathology , Spinal Fractures/therapy , Stress, Mechanical
10.
Spine (Phila Pa 1976) ; 32(11): E340-7, 2007 May 15.
Article in English | MEDLINE | ID: mdl-17495768

ABSTRACT

STUDY DESIGN: A histologic, biologic, and immunohistochemical assessment using human samples of the lumbar ligamentum flavum. OBJECTIVE: To prove our hypothesis that hypertrophy of the ligamentum flavum is caused by accumulation of inflammation-related scar tissue. SUMMARY OF BACKGROUND DATA: Lumbar spinal canal stenosis is 1 of the most common spinal disorders in elderly patients. Canal narrowing, in part, results from hypertrophy of the ligamentum flavum. The hypertrophy mechanism remains unclear. Based on our preliminary analyses, we have previously proposed that the hypertrophy may be due to accumulation of scar tissue in the ligament. Scar tissue is reported to develop after inflammation; however, there is no report, including our previous study, on inflammation in the ligamentum flavum. There is a need for an in-depth investigation of any relationship between inflammation and scar formation in the ligamentum flavum. If inflammation is related to hypertrophy, we may control/delay the hypertrophy by inhibiting the inflammation. METHODS: Twenty-one ligamentum flavum samples were obtained for the histologic study. Trichrome and Verhoeff-van Gieson stains were used to assess the degree of fibrosis (scarring) and content of elastic fibers, respectively. Two ligamentum flavum samples, hypertrophied and thin control ligaments, were used for a global genetic assessment by oligonucleotide gene array technology with gene chips. Messenger ribonucleic acid expression of cyclooxygenase (COX)-2 was quantitatively measured from 16 ligamentum flavum samples using real-time reverse transcriptase polymerase chain reaction. Immunohistochemistry evaluated the cellular location of COX-2 in ligamentum flavum. RESULTS: In the hypertrophied ligament, severe fibrosis (scarring) was observed in the entire area of the ligamentum flavum, and the severity of scarring showed a significant (r = 0.79; P < 0.0001) and positive linear correlation with ligamentum flavum thickness. Gene array results showed in both thin/control and hypertrophied ligaments expression of inflammation-related genes such as COX-2, tumor necrosis factor-alpha, and interleukin-1, 6, 8, and 15. Real-time polymerase chain reaction showed COX-2 messenger ribonucleic acid expression in all ligamentum flavum samples. Its expression showed weak positive linear correlation with the thickness of ligament. COX-2 was released from vascular endothelial cells in ligamentum flavum as per the immunohistochemical analysis. CONCLUSIONS: Accumulation of fibrosis (scarring) causes hypertrophy of the ligamentum flavum. Inflammation-related gene expression is found in the ligamentum flavum. It might be possible to prevent the hypertrophy of ligamentum flavum with antiinflammatory drugs.


Subject(s)
Cicatrix/complications , Inflammation/complications , Ligamentum Flavum/pathology , Lumbar Vertebrae , Spinal Stenosis/etiology , Adult , Aged , Cicatrix/etiology , Cicatrix/metabolism , Cicatrix/pathology , Cyclooxygenase 2/analysis , Cyclooxygenase 2/genetics , Fibrosis , Gene Expression , Gene Expression Profiling , Humans , Hypertrophy , Immunohistochemistry , Inflammation/genetics , Inflammation/metabolism , Inflammation/pathology , Interleukins/analysis , Interleukins/genetics , Ligamentum Flavum/chemistry , Linear Models , Membrane Proteins/analysis , Membrane Proteins/genetics , Middle Aged , Oligonucleotide Array Sequence Analysis , RNA, Messenger/analysis , Reverse Transcriptase Polymerase Chain Reaction , Severity of Illness Index , Spinal Stenosis/metabolism , Spinal Stenosis/pathology , Tumor Necrosis Factor-alpha/analysis , Tumor Necrosis Factor-alpha/genetics
11.
Spine (Phila Pa 1976) ; 32(25): 2805-11, 2007 Dec 01.
Article in English | MEDLINE | ID: mdl-18246001

ABSTRACT

STUDY DESIGN: A histologic, biologic, and immunohistochemical assessment using human samples of lumbar ligamentum flavum. OBJECTIVE: To clarify the pathomechanism of loss of elasticity and hypertrophy of the lumbar ligamentum flavum (LF) in the elderly population. SUMMARY OF BACKGROUND DATA: The most common spinal disorder in elderly patients is lumbar spinal canal stenosis, causing low back and leg pain, and paresis. Canal narrowing, in part, results from hypertrophy of the LF. Although histologic and biologic literature on this topic is available, the pathomechanism of loss of elasticity and hypertrophy of the LF is still unknown. METHODS: One fetus, 5 young, and 5 elderly LF were obtained for histologic study. Hematoxylin and eosin, Alcian blue, Masson Trichrome, and Elastica Van Gieson stains were performed for each LF. Nine LF were collected and were used for biologic study of real time RT-PCR to quantitatively measure mRNA expression of Type I collagen and elastin in each LF. RESULTS: In the LF of the fetus, elastic fibers accounted for about 75% of the entire area. In the dural aspect of the LF in the young and elderly group, the ratio was also around 75%; however, the ratio of the dorsal aspect decreased with age. Almost half of the area showing loss of elastic fibers was shown to be converted to cartilaginous tissue producing Type II collagen and proteoglycan by Alcian blue and Type II collagen immunohistochemistry. The area, which did not stain black with EV nor blue with AB stain, was positively stained blue with T stain, indicating scarring. The area of the normal dural layer was 18.0 +/- 2.3 and 33.8 +/- 4.3 (mm2), for young and elderly group, respectively. Accordingly, it was 3.2 +/- 0.8 and 18.0 +/- 10.2 (mm2), for the dorsal abnormal layer. Elastin mRNA showed a relatively strong correlation (r = 0.44) with age; however, the slope was very gentle. Type I collagen mRNA showed a very strong correlation (r = 0.80) with age. The slope was steeper, and the value reached at 1000% (10-fold) around 65 years old when compared with the LF from younger patient. Elastin mRNA showed a weak correlation (r = 0.36) with thickness, and the slope was gentle. Type I collagen mRNA showed relatively strong correlation (r = 0.52) with thickness. The slope was steeper, and the line reached at 1000% (10-fold) around 6.5 (mm) when compared with a thin LF. CONCLUSION: Decreased elasticity of LF in the elderly is due to the loss of elastic fibers and a concomitant increase of collagenous fibers in the dorsal aspect. LF hypertrophy could be due to the thickening of the normal elastic layer as well as of the abnormal collagenous layer.


Subject(s)
Aging/pathology , Ligamentum Flavum/pathology , Lumbar Vertebrae/pathology , Spinal Stenosis/pathology , Adult , Age Factors , Aging/metabolism , Collagen Type I/analysis , Collagen Type I/genetics , Collagen Type II/analysis , Elasticity , Elastin/analysis , Elastin/genetics , Fetus/chemistry , Humans , Hypertrophy , Ligamentum Flavum/chemistry , Ligamentum Flavum/embryology , Lumbar Vertebrae/chemistry , Lumbar Vertebrae/embryology , Middle Aged , RNA, Messenger/analysis , Spinal Stenosis/metabolism
12.
Spine (Phila Pa 1976) ; 31(26): E992-8, 2006 Dec 15.
Article in English | MEDLINE | ID: mdl-17172990

ABSTRACT

STUDY DESIGN: To determine the effect of cage/spacer stiffness on the stresses in the bone graft and cage subsidence. OBJECTIVE: To investigate the effect of cage stiffness on the biomechanics of the fused segment in the lumbar region using finite element analysis. SUMMARY OF BACKGROUND DATA: There are a wide variety of cage/spacer designs available for lumbar interbody fusion surgery. These range from circular, tapered, rectangular with and without curvature, and were initially manufactured using titanium alloy. Recent advances in the medical implant industry have resulted in using medical grade polyetheretherketone (PEEK). The biomechanical advantages of using different cage material in terms of stability, subsidence, and stresses in bone graft are not fully understood. METHODS: A previously validated 3-dimensional, nonlinear finite element model of an intact L3-L5 segment was modified to simulate posterior interbody fusion spacers made of PEEK ("E" = 3.6 GPa) and titanium ("E" = 110 GPa) at the L4/5 disc with posterior instrumentation. Bone graft ("E" = 12 GPa) packed between the spacers in the intervertebral space was also simulated. The posterior lumbar interbody fusion spacer with instrumentation and graft represent a simulation of the condition present immediately after surgery. RESULTS: The peak centroidal Von Mises stresses in the graft bone increased by at least 9-fold with PEEK spacers as compared to titanium spacer. The peak centroidal Von Mises stresses in the endplates increased by at least 2.4-fold with titanium spacers over the PEEK spacers. These stresses were concentrated at places where the spacer interfaced with the endplate. The stiffness of the spacer did not affect the relative motion (stability) across the instrumented (L4/5) segment. CONCLUSIONS: Spacers less stiff than the graft will: (1) provide stability similar to titanium cages in the presence of posterior instrumentation, (2) reduce the stresses in endplates adjacent to the spacers, and (3) increase the load transfer through the graft, as evident from the increase in stresses in graft.


Subject(s)
Biocompatible Materials , Ketones , Lumbar Vertebrae , Polyethylene Glycols , Spinal Fusion/instrumentation , Titanium , Benzophenones , Biomechanical Phenomena , Bone Transplantation/instrumentation , Finite Element Analysis , Humans , Models, Theoretical , Polymers , Prostheses and Implants
13.
Spine J ; 6(6): 659-66, 2006.
Article in English | MEDLINE | ID: mdl-17088196

ABSTRACT

BACKGROUND CONTEXT: Biomechanical studies of artificial discs that quantify parameters such as load sharing and stresses have been reported in literature for single-level disc placements. However, literature on the effects of using the Charité artificial disc (ChD) at two levels (2LChD) as compared with one-level fusion (using a cage [CG] and a pedicle screw system) plus one-level artificial disc combination (CGChD) is sparse. PURPOSE: To determine the effects of the 2LChD and CGChD across the implanted and adjacent segments. STUDY DESIGN: A finite element model of a L3-S1 segment was used to compare the biomechanical effects of the ChD placed at two lower levels (2LChD model) with L5-S1 fusion (using a CG and a pedicle screw system) plus L4-L5 level ChD placement combination (CGChD model). METHODS: We used our recently published and experimentally validated L3-S1 finite element model for the present study. The intact model was subjected to 400 N axial compression and 10.6 Nm of flexion/extension moments. The experimental constructs described above were then subjected to 400 N axial compression and a moment that produced overall motion equal to the intact model predictions (hybrid testing protocol). Resultant motion, loads across facets, and other parameters were analyzed at the experimental and adjacent levels. RESULTS: In flexion, the bending moments for the CGChD and 2LChD models were 15.4 Nm (fusion effect) and 7.3 Nm (increase in flexibility effect), respectively in comparison to 10.6 Nm for the intact model. The corresponding values in the extension mode were 11.2 Nm and 7.2 Nm. The predicted flexion rotations across the L5-S1 segment for the CGChD decreased by 76% (fusion effect), and increased at the L4-L5 and the L3-L4 levels by 68.5% and 28%, respectively. In the extension mode, motion across the L5-S1 segment decreased by 96.4% whereas it increased 74.6% and 18.2% across the L4-L5 and L3-L4 levels, respectively. For the 2LChD model, the flexion rotation across the L5-S1 segment increased by 28.2%. The motions across the L4-L5 and L3-L4 segments decreased by 12% and 24%, respectively. In extension, the corresponding changes were 10% increase, 10% increase, and 21% decrease at the L5-S1, L4-L5, and L3-L4 levels, respectively. The facet loads were in line with the changes in motion, except for the 2LChD case. CONCLUSIONS: The changes at L3-L4 level for both of the cases were of similar magnitude (approximately 25%), although in the CGChD model it increased and in the 2LChD model it decreased. The changes in motion at the L4-L5 level were large for the CGChD model as compared with the 2LChD model predictions (approximately 70% increase vs. 10% increase). It is difficult to speculate if an increase in motion across a segment, as compared with the intact case, is more harmful than a decrease in motion.


Subject(s)
Biomechanical Phenomena , Finite Element Analysis , Intervertebral Disc/surgery , Models, Neurological , Spinal Fusion/methods , Humans , Lumbar Vertebrae/surgery , Range of Motion, Articular
14.
Spine (Phila Pa 1976) ; 31(19): 2189-94, 2006 Sep 01.
Article in English | MEDLINE | ID: mdl-16946652

ABSTRACT

STUDY DESIGN: Biomechanical study to investigate three-dimensional motion behavior of cadaveric spines in various surgical simulations. OBJECTIVES: To determine the effect of cage geometry on the construct stability. SUMMARY OF BACKGROUND DATA: There is a wide variety of cage/spacer designs available for lumbar interbody fusion surgery. These range from circular, tapered, and rectangular with and without curvature. However, the effectiveness of cages with different designs and materials to stabilize a decompressed intervertebral space has not been fully studied. METHODS: Six fresh ligamentous lumbar spine specimens (L1-S2) were subjected to pure moments in the six loading directions. The resulting spatial orientations of the vertebrae were recorded using Optotrak Motion Measurement System. Measurements were made sequentially for intact, bilateral spacer placements across L4-L5 using a posterior approach, supplemented with pedicle screw-rod system fixation, and after the cyclic loading in flexion-extension mode. RESULTS: The stability tended to decrease after the bilateral cage placement as compared with the intact for all loading cases except flexion. In flexion, the angular displacement decreased to 80% of the intact. However, there was no significant statistical difference seen in stability between intact and after bilateral spacer placement. Following the addition of posterior fixation using pedicle screw-rod system, the stability significantly increased in all directions. Cyclic loading did not have any significant effect on the stability. CONCLUSIONS: Stand-alone cages restore motion to near-intact levels at best, and supplement instrumentation is essential for significantly increasing the stability of the decompressed segment. The effects of cage geometry and Young's modulus of the cage material do not seem to influence the stability, as compared with the other cagedesigns, especially after supplemental fixation with a posterior system.


Subject(s)
Internal Fixators , Spinal Fusion/instrumentation , Aged , Aged, 80 and over , Biomechanical Phenomena , Cadaver , Equipment Design , Female , Humans , Joint Instability/prevention & control , Lumbar Vertebrae , Male , Middle Aged , Range of Motion, Articular
15.
Eur Spine J ; 15(6): 930-5, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16614856

ABSTRACT

A non-linear 3-dimensional finite element pediatric lumbar spine model with vertebral growth plate and apophyseal bony ring was developed. Lumbar spondylolysis was simulated in the model. The Von Mises stresses in the structures surrounding the vertebral growth plate, including apophyseal bony ring and osseous endplate were calculated in various loading modes. Instantaneous axis of rotation (IAR) path from flexion to extension was also analyzed. The results were compared with those of the intact model and the literature. The IAR path was at the posterior disc-endplate space of the lower vertebra in the intact spine, and moved cranially towards the upper-posterior disc space in the lytic spine. This was in agreement with in vivo radiological data by Sakamaki et al. [19]. During various loading modes, stresses in the spondylolytic pediatric model were higher than that of the intact model; ranging from 1.1 to 6.0 times, with the highest value in extension at the growth plate. In conclusion, FE models indicate that stress concentrations in the lytic model increase at the growth plate which may lead to physis stress fracture leading to spondylolisthesis.


Subject(s)
Lumbar Vertebrae/physiopathology , Spondylolisthesis/etiology , Spondylolisthesis/physiopathology , Biomechanical Phenomena , Child , Finite Element Analysis , Growth Plate/pathology , Growth Plate/physiopathology , Humans , Lumbar Vertebrae/pathology , Models, Anatomic , Models, Biological , Spondylolisthesis/pathology
16.
Eur Spine J ; 15(6): 923-9, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16614857

ABSTRACT

The purpose of this study was to (1) develop a three-dimensional, nonlinear pediatric lumbar spine finite element model (FEM), and (2) identify the mechanical reasons for the posterior apophyseal bony ring fracture in the pediatric patients. The pediatric spine FE model was created from an experimentally validated three-dimensional adult lumbar spine FEM. The size of the FEM was reduced to 96% taking into account of the ratio of the sitting height of an average 14-years-old children to that of an adult. The pediatric spine was created with anatomically specific features like the growth plate and the apophyseal bony ring. For the stress analyses, a 10-N m moment was applied in all the six directions of motion for the lumbar spine. A preload of 351 N was applied which corresponds to the mean body weight of the 14-years-old group. The stresses at the apophyseal bony ring, growth plate and endplate were calculated. The results indicate that the structures surrounding the growth plate including apophyseal bony ring and osseous endplate were highly stressed, as compared to other structures. Furthermore, posterior structures in extension were in compression whereas in flexion they were in tension, with magnitude of stresses higher in extension than in flexion. Over time, the higher compression stresses along with tension stresses in flexion may contribute to the apophyseal ring fracture (fatigue phenomena).


Subject(s)
Lumbar Vertebrae/injuries , Lumbar Vertebrae/physiopathology , Spinal Fractures/pathology , Spinal Fractures/physiopathology , Adult , Biomechanical Phenomena , Child , Finite Element Analysis , Humans , Lumbar Vertebrae/pathology , Models, Anatomic , Models, Biological
17.
Spine (Phila Pa 1976) ; 31(7): E198-202, 2006 Apr 01.
Article in English | MEDLINE | ID: mdl-16582840

ABSTRACT

STUDY DESIGN: Computerized tomography (CT) of the lumbar spine cadaveric specimens was used to evaluate the effect of increasing the height of the disc space in the lumbar spine to the facet joint articulation in the sagittal plane. OBJECTIVE: To show how the facet joint articulation is affected by increasing the height of the disc space in the lumbar spine. SUMMARY OF BACKGROUND DATA: The Charité Artificial Disc (DePuy Spine, Inc., Raynham, MA) was successful in relieving low back pain in the majority of patients, yet there was still a significant number of patients who did not obtain pain relief, or their pain even worsened. The etiology of their pain is still not known. To our knowledge, no study has addressed the effect on the facet joints when the disc height is increased. METHODS: CT images passing through the center of the L3-S1 facet joints (sagittal plane) were obtained from 15 cadaveric lumbar spine specimens. The articulation overlap of facet joints in sagittal plane from the L3 to S1 was measured. A 1-mm incremental increase to a total 5 mm in disc space height was performed to simulate the changes seen in disc replacement. The change in the facet joint articulation overlap in sagittal plane at normal and each displacement was then measured. There were 5 lumbar spine specimens dissected to validate the technique and standardize the measurements. Mean, percentages, and standard deviation values were calculated for all measured dimensions. RESULTS: No significant difference was found between the measurements on CT and gross specimens (P > 0.05). In 15 specimens, the mean facet joint articulation overlap on the sagittal plane was: 16.29 +/- 1.20 mm (left) and 16.22 +/- 1.16 (right) at the L3-L4 level; 17.81 +/- 1.18 mm (left) and 17.74 +/- 1.18 mm (right) at the L4-L5 level; and 18.18 +/- 1.18 mm (left) and 18.23 +/- 1.15 mm (right) at the L5-S1 level. There is no significant difference between the measured values on left and right sides (P > 0.05). Each 1-mm incremental increase in disc space at the L3-L4 level translated to a decrease in the facet joint articulation overlap in the sagittal plane by 6%, and the mean facet joint space increased 0.4 mm. At the L4-L5 level, the articulation overlap decreased by 6%, and the facet joint space increased 0.5 mm. At the L5-S1 level, the articulation overlap decreased by 4%, and the facet joint space increased 0.7 mm. CONCLUSIONS: There is a significant decrease of the facet joint articulation overlap in sagittal plane and an increase in the facet joint space following an increase in the lumbar disc space. The inappropriate increase of the height of disc space will result in facet joint subluxation.


Subject(s)
Intervertebral Disc/diagnostic imaging , Lumbar Vertebrae/diagnostic imaging , Zygapophyseal Joint , Humans , Intervertebral Disc/pathology , Lumbar Vertebrae/pathology , Tomography, X-Ray Computed/methods , Zygapophyseal Joint/pathology
18.
Spine (Phila Pa 1976) ; 31(2): 206-11, 2006 Jan 15.
Article in English | MEDLINE | ID: mdl-16418642

ABSTRACT

STUDY DESIGN: Clinical review of pediatric patients with lumbar spondylolysis and biomechanical analysis using finite-element lumbar spine model. OBJECTIVES: To evaluate the usefulness of the signal changes observed on MR images of the pedicle for the early diagnosis of spondylolysis, and to investigate the pathomechanism of the signal changes based on the stresses in pedicles, as predicted using finite-element analyses. Furthermore, to evaluate the usefulness of the signal change to predict the bony healing following conservative treatment. SUMMARY OF BACKGROUND DATA: Since early-stage spondylolysis can achieve osseous healing conservatively, it is important to diagnose this disorder as early as possible. Presently, there is no well-established, noninvasive, and reliable diagnostic tool for the early diagnosis. METHODS: Thirty-seven pediatric patients with spondylolysis were included. Sixty-eight defects were examined and their stages as revealed on CT scans were recorded. High signal changes (HSC) of the pedicles on axial T2-weighted MRI were compared with the CT-based stages of the defect. Among them, 16 patients, including 15 boys and 1 girl, were treated conservatively for at least a 3-month period. Bony healing of the fracture site was evaluated on CT, and the results were compared between two groups with or without HSC at the initial consultation. Using a three-dimensional nonlinear finite-element model of the L3-L5 segment, stress distributions in the pars and pedicle regions were analyzed in response to 400 N compression and 10.6 Nm moment. RESULTS: Based on CTs, 68 pars defects were classified as follows: 8 very early, 24 late-early, 16 progressive, and 20 terminal stages. All defects in very early and late-early stages (100%) showed HSC on T2-weighted MRI at the ipsilateral pedicle. Among 16 progressive stages, eight (50%) showed HSC, while no defects of the terminal stage (0%) were found to have HSC. In total, 29 pars defects were treated conservatively out of 16 patients. In 19 of the HSC positive defects, 15 (79%) showed bony healing after the conservative treatment, whereas none of the 10 HSC negative defects (0%) showed any healing. The results were statistically significant at P < 0.05 (chi). Stress results from the finite-element model indicated that pars interarticularis showed the highest value in all loading modes, and the pedicle showed the second highest. CONCLUSIONS: The correlation between the high stresses in the pedicle and the corresponding HSC suggest that signal changes in MRI could be used as an indicator for early diagnosis of spondylolysis. The HSC of the pedicle provided useful information to diagnose early stage spondylolysis. Furthermore, the HSC may be a good indicator as to whether a bony union will result from conservative treatment.


Subject(s)
Biomechanical Phenomena/methods , Lumbar Vertebrae/diagnostic imaging , Magnetic Resonance Imaging/methods , Spondylolysis/diagnostic imaging , Spondylolysis/diagnosis , Adolescent , Child , Early Diagnosis , Female , Follow-Up Studies , Humans , Male , Radiography , Retrospective Studies
19.
Spine (Phila Pa 1976) ; 30(23): 2649-56, 2005 Dec 01.
Article in English | MEDLINE | ID: mdl-16319751

ABSTRACT

STUDY DESIGN: A multidisciplinary study involving clinical, histologic, biomechanical, biologic, and immunohistologic approaches. OBJECTIVE.: To clarify the pathomechanism of hypertrophy of the ligamentum flavum. SUMMARY OF BACKGROUND DATA: The most common spinal disorder in elderly patients is lumbar spinal canal stenosis, causing low back and leg pain, and paresis. Canal narrowing, in part, results from hypertrophy of the ligamentum flavum. Although histologic and biologic literature on this topic is available, the pathomechanism of ligamentum flavum hypertrophy is still unknown. METHODS: The thickness of 308 ligamenta flava at L2/3, L3/4, L4/5, and L5/S1 levels of 77 patients was measured using magnetic resonance imaging. The relationships between thickness, age, and level were evaluated. Histologic evaluation was performed on 20 ligamentum flavum samples, which were collected during surgery. Trichrome and Verhoeff-van Gieson elastic stains were performed for each ligamentum flavum to understand the degree of fibrosis and elastic fiber status, respectively. To understand the mechanical stresses in various layers of ligamentum flavum, a 3-dimensional finite element model was used. Von Mises stresses were computed, and values between dural and dorsal layers were compared. There were 10 ligamenta flava collected for biologic assessment. Using real-time reverse transcriptase polymerase chain reaction, transforming growth factor (TGF)-beta messenger ribonucleic acid expression was quantitatively measured. The cellular location of TGF-beta was also confirmed from 18 ligamenta flava using immunohistologic techniques. RESULTS: The ligamentum flavum thickness increased with age, however, the increment at L4/5 and L3/4 levels was larger than at L2/3 and L5/S1 levels. Histology showed that as the ligamentum flavum thickness increased, fibrosis increased and elastic fibers decreased. This tendency was more predominant along the dorsal side. Von Misses stresses revealed that the dorsal fibers of ligamentum flavum were subjected to higher stress than the dural fibers. This was most remarkably observed at L4/5. The largest increase in ratio observed between the dorsal and dural layer was approximately 5-fold in flexion at L4/5 in flexion. Expression of TGF-beta was observed in all ligamenta flava, however, the expression decreased as the ligamentum flavum thickness increased. Immunohistochemistry showed that TGF-beta was released by the endothelial cells, not by fibroblasts. CONCLUSIONS: Fibrosis is the main cause of ligamentum flavum hypertrophy, and fibrosis is caused by the accumulation of mechanical stress with the aging process, especially along the dorsal aspect of the ligamentum flavum. TGF-beta released by the endothelial cells may stimulate fibrosis, especially during the early phase of hypertrophy.


Subject(s)
Ligamentum Flavum/pathology , Lumbar Vertebrae/pathology , Spinal Stenosis/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Biomechanical Phenomena/methods , Child , Female , Humans , Hypertrophy , Image Processing, Computer-Assisted/methods , Immunohistochemistry , Ligamentum Flavum/chemistry , Ligamentum Flavum/physiopathology , Lumbar Vertebrae/chemistry , Lumbar Vertebrae/physiopathology , Male , Middle Aged , Spinal Canal/chemistry , Spinal Canal/pathology , Spinal Canal/physiopathology , Spinal Stenosis/physiopathology
20.
Spine (Phila Pa 1976) ; 30(24): 2755-64, 2005 Dec 15.
Article in English | MEDLINE | ID: mdl-16371899

ABSTRACT

STUDY DESIGN: Finite element model of L3-S1 segment and confirmatory cadaveric testing were used to investigate the biomechanical effects of a mobile core type artificial disc (Charité artificial disc; DePuy Spine, Raynham, MA) on the lumbar spine. OBJECTIVE: To determine the effects of the Charité artificial disc across the implanted and adjacent segments. SUMMARY OF BACKGROUND DATA: Biomechanical studies of artificial discs that quantify parameters, like the load sharing and stresses, are sparse in the literature, especially for mobile-type core artificial disc designs. In addition, there is no standard protocol for studying the adjacent segmental effects of such implants. METHODS: Human osteo-ligamentous spines (L1-S1) were tested before and after L5-S1 Charité artificial disc placement. The data were used to validate further an intact 3-dimensional (3-D) nonlinear L3-S1 finite element model. The model was subjected to 400-N axial compression and 10.6 Nm of flexion/extension pure moments (load control) or pure moments that produced the overall rotation of the L3-S1 Charité model equal to the intact case (hybrid approach). Resultant motion, load, and stress parameters were analyzed at the experimental and adjacent levels. RESULTS: Finite element model validation was achieved only with the load-controlled experiments. The hybrid approach, believed to be more clinically relevant, revealed that Charité artificial disc leads to motion increases in flexion (19%) and extension (44%) at the L5-S1 level. At the instrumented level, the decrease in the facet loads was less than at the adjacent levels; the corresponding decrease being 26% at L3-L4, 25% at L4-L5, and 13.4% at L5-S1 when compared to the intact. Intradiscal pressure changes in the L4-L5 and L3-L4 segments were minimal. Shear stresses at the Charité artificial disc-L5 endplate interface were higher than those at S1 interface. However, in the load control mode, the increase in facet loads in extension was approximately 14%, as compared to the intact case. CONCLUSIONS: The hybrid testing protocol is advocated because it better reproduces clinical observations in terms of motion following surgery, using pure moments. Using this approach, we found that the Charité artificial disc placement slightly increases motion at the implanted level, with a resultant increase in facet loading when compared to the adjacent segments, while the motions and loads decrease at the adjacent levels. However, in the load control mode that we believe is not that clinically relevant, there was a large increase in motion and a corresponding increase in facet loads, as compared to the intact.


Subject(s)
Biomechanical Phenomena/standards , Implants, Experimental/standards , Intervertebral Disc/physiology , Lumbar Vertebrae/physiology , Models, Biological , Biomechanical Phenomena/methods , Humans , Image Processing, Computer-Assisted , Intervertebral Disc/surgery , Lumbar Vertebrae/surgery , Weight-Bearing/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...