Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 62(18): 7440-7450, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-28678023

ABSTRACT

The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min-1. Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean: R 2 = 0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.


Subject(s)
Neoplasms/radiotherapy , Particle Accelerators/instrumentation , Quality Assurance, Health Care/standards , Radiotherapy Setup Errors/prevention & control , Radiotherapy, Intensity-Modulated/instrumentation , Radiotherapy, Intensity-Modulated/standards , Humans , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated/methods
2.
Z Med Phys ; 25(2): 104-11, 2015 Jun.
Article in English | MEDLINE | ID: mdl-24743059

ABSTRACT

PURPOSE: To investigate the plan quality of two different volumetric modulated arc therapy (VMAT) techniques for lymph node-positive left-sided breast cancer. METHODS: Two VMAT plans were generated for 10 lymph node-positive left-sided breast cancer patients: one plan using one single segment of a full rotation, typically an arc segment of 230° (1s-VMAT); and a second plan consisting of 2 small tangential arc segments of about 50° (2s-VMAT). For plan comparison, various dose and dose volume metrics (Dmean, D98%, D2% for target volumes, D2%, Dmean and Vx% for organs at risk (OAR)) were evaluated. RESULTS: Both techniques fulfilled both clinical target dose and OAR goals. 1s-VMAT achieved a slightly better homogeneity and better target coverage (D2%= 54.2 ± 0.7 Gy, D98%= 30.3 ± 1.8 Gy) compared to 2s-VMAT (D2%= 55.0 ± 1.1 Gy, D98%= 29.9 ± 1.7 Gy). For geometrical reasons, OAR sparing was noticeable but not significant better using 2s-VMAT, particularly heart and contralateral breast. The heart received a mean dose of 4.4 ± 0.8 Gy using 1s-VMAT and 3.3 ± 1.0 Gy using 2s-VMAT; the contralateral breast received 1.5 ± 0.3 Gy and 0.9 ± 0.3 Gy, respectively. CONCLUSIONS: A VMAT technique based on two small tangential arc segments enables improved OAR sparing; the differences between the two techniques in target coverage and homogeneity are minor. Patient age and -anatomy must be considered for each individual case when deciding which technique to be used.


Subject(s)
Carcinoma/radiotherapy , Carcinoma/secondary , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Unilateral Breast Neoplasms/radiotherapy , Female , Humans , Lymph Nodes/radiation effects , Lymphatic Metastasis , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...