Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-26540683

ABSTRACT

This paper presents the design, fabrication, and experimental evaluation of a prototype lead zirconium titanate (PZT) matrix transducer with an integrated receive ASIC, as a proof of concept for a miniature three-dimensional (3-D) transesophageal echocardiography (TEE) probe. It consists of an array of 9 ×12 piezoelectric elements mounted on the ASIC via an integration scheme that involves direct electrical connections between a bond-pad array on the ASIC and the transducer elements. The ASIC addresses the critical challenge of reducing cable count, and includes front-end amplifiers with adjustable gains and micro-beamformer circuits that locally process and combine echo signals received by the elements of each 3 ×3 subarray. Thus, an order-of-magnitude reduction in the number of receive channels is achieved. Dedicated circuit techniques are employed to meet the strict space and power constraints of TEE probes. The ASIC has been fabricated in a standard 0.18-µm CMOS process and consumes only 0.44 mW/channel. The prototype has been acoustically characterized in a water tank. The ASIC allows the array to be presteered across ±37° while achieving an overall dynamic range of 77 dB. Both the measured characteristics of the individual transducer elements and the performance of the ASIC are in good agreement with expectations, demonstrating the effectiveness of the proposed techniques.


Subject(s)
Echocardiography, Three-Dimensional/instrumentation , Echocardiography, Transesophageal/instrumentation , Lead/chemistry , Signal Processing, Computer-Assisted/instrumentation , Titanium/chemistry , Transducers , Zirconium/chemistry , Equipment Design
2.
Ultrasound Med Biol ; 38(10): 1820-32, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22958515

ABSTRACT

Transesophageal echocardiography (TEE) uses the esophagus as an imaging window to the heart. This enables cardiac imaging without interference from the ribs or lungs and allows for higher frequency ultrasound to be used compared with transthoracic echocardiography (TTE). TEE facilitates the successful imaging of obese or elderly patients, where TTE may be unable to produce images of satisfactory quality. Recently, three-dimensional (3-D) TEE has been introduced, which greatly improves the image quality and diagnostic value of TEE by adding an extra dimension. Further improvement could be achieved by optimizing 3-D TEE for harmonic imaging. This article describes the optimal geometry and element configuration for a matrix probe for 3-D second harmonic TEE. The array concept features separated transmit and receive subarrays. The element geometry was studied using finite element modeling and a transmit subarray prototype was examined both acoustically and with laser interferometry. The transmit subarray is suitable for its role, with a 3 MHz resonance frequency, a 40%-50% -3 dB bandwidth and crosstalk levels <-27 dB. The proposed concept for the receive subarray has a 5.6 MHz center frequency and a 50% -3 dB bandwidth.


Subject(s)
Echocardiography, Three-Dimensional/instrumentation , Echocardiography, Transesophageal/instrumentation , Image Enhancement/instrumentation , Transducers , Computer Simulation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Models, Theoretical , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity , Sound
3.
Article in English | MEDLINE | ID: mdl-22828845

ABSTRACT

There is a clear clinical need for creating 3-D images of the heart. One promising technique is the use of transesophageal echocardiography (TEE). To enable 3-D TEE, we are developing a miniature ultrasound probe containing a matrix piezoelectric transducer with more than 2000 elements. Because a gastroscopic tube cannot accommodate the cables needed to connect all transducer elements directly to an imaging system, a major challenge is to locally reduce the number of channels, while maintaining a sufficient signal-to-noise ratio. This can be achieved by using front-end receiver electronics bonded to the transducers to provide appropriate signal conditioning in the tip of the probe. This paper presents the design of such electronics, realizing time-gain compensation (TGC) and micro-beamforming using simple, low-power circuits. Prototypes of TGC amplifiers and micro-beamforming cells have been fabricated in 0.35-µm CMOS technology. These prototype chips have been combined on a printed circuit board (PCB) to form an ultrasound-receiver system capable of reading and combining the signals of three transducer elements. Experimental results show that this design is a suitable candidate for 3-D TEE.


Subject(s)
Algorithms , Echocardiography, Three-Dimensional/instrumentation , Echocardiography, Transesophageal/instrumentation , Electronics/instrumentation , Image Interpretation, Computer-Assisted/instrumentation , Information Storage and Retrieval/methods , Pattern Recognition, Automated/methods , Signal Processing, Computer-Assisted/instrumentation , Transducers , Equipment Design , Equipment Failure Analysis , Image Enhancement/instrumentation , Reproducibility of Results , Sensitivity and Specificity