Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 96
Filter
1.
Am J Cardiol ; 222: 23-28, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38692400

ABSTRACT

The Navitor transcatheter heart valve (THV) is the latest iteration of the Portico self-expanding valve system. Early prospective studies have shown promising outcomes, however, there is a lack of complementary 'real-world' data. This study aimed to assess early safety and efficacy outcomes of the Navitor THV using registry data from 6 high-volume United Kingdom transcatheter aortic valve replacement (TAVR) centers. Demographic, procedural, and in-hospital outcome data were retrieved from 6 United Kingdom centers. The primary safety end point was 30-day mortality. Primary efficacy end points were procedural success, mean aortic gradient, and ≥moderate paravalvular leak. Secondary end points included rates of new permanent pacemaker implantation, stroke, and vascular injury. A total of 574 patients (mean age 83.4 years; 54.5% female) underwent Navitor TAVR between January 2020 and May 2023. The 30-day mortality in this patient cohort was 1.6%. Procedural success was 98.1%, mean echo-derived gradient post-TAVR was 7.7 ± 4.8 mm Hg (95% confidence interval [CI] 7.2 to 8.3, p <0.001) and 5.1% of patients had ≥moderate paravalvular leak (sample proportion estimate [p̂] = 0.051, 95% CI [0.035, 0.073], p <0.001). New permanent pacemaker implantation to discharge was required in 11% (p̂ = 0.119, 95% CI 0.088 to 0.158, p <0.001), stroke occurred in 1.2% of patients (p̂ = 0.017, 95% CI 0.006 to 0.036, p <0.001) and significant vascular injury in 1.6% (p̂ = 0.014, 95% CI 0.005 to 0.032, p <0.001). In conclusion, early procedural outcomes with Navitor TAVR compare favorably to new-generation THVs. Procedural success was high with a low incidence of complications.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Female , Male , United Kingdom/epidemiology , Aged, 80 and over , Aortic Valve Stenosis/surgery , Prosthesis Design , Aged , Postoperative Complications/epidemiology , Treatment Outcome , Aortic Valve/surgery
2.
Eur Heart J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

3.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

4.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38587261

ABSTRACT

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Bioprosthesis , Heart Valve Prosthesis , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Female , Male , Transcatheter Aortic Valve Replacement/adverse effects , Aged, 80 and over , Aged , Aortic Valve/surgery , Bioprosthesis/adverse effects , Kaplan-Meier Estimate , Stroke/etiology , Heart Failure , Postoperative Complications/etiology , Prosthesis Failure
5.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38180419

ABSTRACT

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Pandemics , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/epidemiology , Treatment Outcome , COVID-19/epidemiology , Registries , Risk Factors
6.
Article in English | MEDLINE | ID: mdl-38262740

ABSTRACT

BACKGROUND AND AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing transcatheter aortic valve intervention (TAVI). METHODS: We followed the European Society of Cardiology (ESC) methodology for the development of QIs. Key domains were identified by constructing a conceptual framework for the delivery of TAVI care. A list of candidate QIs were developed by conducting a systematic review of the literature. A modified Delphi method was then used to select the final set of QIs. Finally, we mapped the QIs to the EuroHeart Data Standards for TAVI to ascertain the extent to which the EuroHeart TAVI registry captures information to calculate the QIs. RESULTS: We formed an international group of experts in quality improvement and TAVI, including representatives from the European Association of Percutaneous Cardiovascular Interventions, the European Association of Cardiovascular Imaging and the Association of Cardiovascular Nursing & Allied Professions. In total, 27 QIs were selected across eight domains of TAVI care, comprising 22 main (81%) and five secondary (19%) QIs. Of these, 19/27 (70%) are now being utilised in the EuroHeart TAVI registry. CONCLUSION: We present the 2023 ESC QIs for TAVI, developed using a standard methodology and in collaboration with ESC Associations. The EuroHeart TAVI registry allows calculation of the majority of the QIs, which may be used for benchmarking care and quality improvement initiatives.

7.
Circ Cardiovasc Interv ; 16(11): e013296, 2023 11.
Article in English | MEDLINE | ID: mdl-37988436

ABSTRACT

BACKGROUND: Redo transcatheter aortic valve implantation (TAVI) is increasing as patients outlive their transcatheter heart valves (THVs) and present with bioprosthetic valve failure. The Lotus mechanically expanded THV has unique design characteristics, which have specific implications for Redo TAVI. METHODS: The design features of the Lotus valve and their relevance to Redo TAVI were reviewed. Bench-top analysis of Redo TAVI was performed using different contemporary THVs. Procedural and outcome data were obtained from 10 patients who had undergone Redo TAVI for Lotus bioprosthetic valve failure in 5 centers. Recommendations for performing Redo TAVI in Lotus are made, based on these findings. RESULTS: The Lotus leaflets extend from the frame inflow, with a Neoskirt of only 13 mm, hence a low risk of coronary obstruction during Redo TAVI. The Lotus frame posts prevent full apposition of the Redo prosthesis in the upper part of the frame, while implantation of the Redo THV above the Lotus inflow leads to inadequate apposition of the Lotus leaflets. Inflow-to-inflow positioning is therefore recommended for effective sealing and leaflet pinning. The Lotus locking mechanism prevents overexpansion of the frame, limiting Redo THV oversizing. Redo TAVI was favorable with SAPIEN 3, Evolut, and Navitor THVs on bench-top analysis but not with ACURATE Neo 2 due to the upper crowns and short stent preventing inflow-to-inflow deployment. Case review demonstrated satisfactory outcomes in 10 patients treated with Evolut (n=6), SAPIEN 3 (n=3), and Portico (n=1) valves, with no mortality, major morbidity, or coronary obstruction. Three patients had residual mean gradient ≥20 mm Hg, including 2 of 3 SAPIEN cases. Guidance on procedural planning, valve choice, sizing, and positioning is provided. CONCLUSIONS: Redo TAVI in Lotus requires an understanding of unique design characteristics, and adherence to key procedural recommendations, but can be safely and effectively performed with most contemporary valve types.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Prosthesis Design , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology
8.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 11.
Article in English | MEDLINE | ID: mdl-37988439

ABSTRACT

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Feasibility Studies , Treatment Outcome , Tomography, X-Ray Computed , Prosthesis Design
9.
Open Heart ; 10(2)2023 Sep.
Article in English | MEDLINE | ID: mdl-37788920

ABSTRACT

OBJECTIVE: To assess gender, ethnicity, and deprivation-based differences in provision of aortic valve replacement (AVR) in England for adults with aortic stenosis (AS). METHODS: We retrospectively identified adults with AS from the English Hospital Episode Statistics (HES) between April 2016 and March 2019 and those who subsequently had an AVR. We separately used HES-linked Clinical Practice Research Datalink (CPRD) to identify people with AVR and evaluate the timeliness of their procedure (CPRD-AVR cohort). ORs for AVR in people with an AS diagnosis were estimated using multivariable logistic regression adjusted for age, region and comorbidity. AVR was considered timely if performed electively and without evidence of cardiac decompensation before AVR. RESULTS: 183 591 adults with AS were identified in HES; of these, 31 436 underwent AVR. The CPRD-AVR cohort comprised 10 069 adults. Women had lower odds of receiving AVR compared with men (OR 0.65; 95% CI 0.63 to 0.66); as did people of black (OR 0.70; 95% CI 0.60 to 0.82) or South Asian (OR 0.75; 95% CI 0.69 to 0.82) compared with people of white ethnicities. People in the most deprived areas were less likely to receive AVR than the least deprived areas (OR 0.8; 95% CI 0.75 to 0.86). Timely AVR occurred in 65% of those of white ethnicities compared with 55% of both those of black and South Asian ethnicities. 77% of the least deprived had a timely procedure compared with 58% of the most deprived; there was no gender difference. CONCLUSIONS: In this large, national dataset, female gender, black or South Asian ethnicities and high deprivation were associated with significantly reduced odds of receiving AVR in England. A lower proportion of people of minority ethnicities or high deprivation had a timely procedure. Public health initiatives may be required to increase clinician and public awareness of unconscious biases towards minority and vulnerable populations to ensure timely AVR for everyone.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Male , Humans , Female , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Heart Valve Prosthesis Implantation/methods , Ethnicity , Risk Factors , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Social Deprivation
10.
Front Cardiovasc Med ; 10: 1227217, 2023.
Article in English | MEDLINE | ID: mdl-37645516

ABSTRACT

Background: A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume. Aims: The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe. Materials and methods: Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice. Results: Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%). Conclusion: Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.

11.
Catheter Cardiovasc Interv ; 101(5): 932-942, 2023 04.
Article in English | MEDLINE | ID: mdl-36924015

ABSTRACT

BACKGROUND: With expansion of transcatheter aortic valve implantation (TAVI) into younger patients, valve durability is critically important. AIMS: We aimed to evaluate long-term valve function and incidence of severe structural valve deterioration (SVD) among patients ≥ 10-years post-TAVI and with echocardiographic follow-up at least 5-years postprocedure. METHODS: Data on patients who underwent TAVI from 2007 to 2011 were obtained from the UK TAVI registry. Patients with paired echocardiograms postprocedure and ≥5-years post-TAVI were included. Severe SVD was determined according to European task force guidelines. RESULTS: 221 patients (79.4 ± 7.3 years; 53% male) were included with median echocardiographic follow-up 7.0 years (range 5-13 years). Follow-up exceeded 10 years in 43 patients (19.5%). Valve types were the supra-annular self-expanding CoreValve (SEV; n = 143, 67%), balloon-expandable SAPIEN/XT (BEV; n = 67, 31%), Portico (n = 4, 5%) and unknown (n = 7, 3%). There was no difference between postprocedure and follow-up peak gradient in the overall cohort (19.3 vs. 18.4 mmHg; p = NS) or in those with ≥10-years follow-up (21.1 vs. 21.1 mmHg; p = NS). Severe SVD occurred in 13 patients (5.9%; median 7.8-years post-TAVI). Three cases (23.1%) were due to regurgitation and 10 (76.9%) to stenosis. Valve-related reintervention/death occurred in 5 patients (2.3%). Severe SVD was more frequent with BEV than SEV (11.9% vs. 3.5%; p = 0.02), driven by a difference in patients treated with small valves (BEV 28.6% vs. SEV 3.0%; p < 0.01). CONCLUSIONS: Hemodynamic function of transcatheter heart valves remains stable up to more than 10 years post-TAVI. Severe SVD occurred in 5.9%, and valve-related death/reintervention in 2.3%. Severe SVD was more common with BEV than SEV.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Registries , United Kingdom , Prosthesis Design
12.
EuroIntervention ; 18(17): 1428-1435, 2023 Apr 24.
Article in English | MEDLINE | ID: mdl-36706009

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is an established treatment for aortic stenosis. Cerebral embolic protection (CEP) devices may impact periprocedural stroke by capturing debris destined for the brain. However, there is a lack of high-quality randomised trial evidence supporting the use of CEP during TAVI. The British Heart Foundation (BHF) PROTECT-TAVI trial will address whether the routine use of CEP reduces the incidence of stroke in patients undergoing TAVI. BHF PROTECT-TAVI is a prospective, open-label, outcome-adjudicated, multicentre randomised controlled trial. The trial is open to all adult patients scheduled for TAVI at participating specialist cardiac centres across the United Kingdom who are able to receive the CEP device. The trial will recruit 7,730 participants. Participants will be randomised in a 1:1 ratio to undergo TAVI with CEP or TAVI without CEP (standard of care). The primary outcome is the incidence of stroke at 72 hours post-TAVI. Key secondary outcomes include the incidence of stroke and all-cause mortality up to 12 months post-TAVI, disability and cognitive outcomes, stroke severity, access site complications and a health economics analysis. The sample size of 7,730 participants has 80% power to detect a 33% relative risk reduction from a 3% incidence of the primary outcome in the controls. Trial recruitment commenced in October 2020. As of October 2022, 3,068 patients have been enrolled. BHF PROTECT-TAVI is designed to provide definitive evidence on the clinical efficacy and cost-effectiveness of using routine CEP with the SENTINEL device to reduce stroke in TAVI.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Prospective Studies , Heart , Aortic Valve Stenosis/therapy , Stroke/etiology , Stroke/prevention & control , Stroke/epidemiology , Treatment Outcome , Aortic Valve/surgery , Risk Factors
13.
Eur Heart J Qual Care Clin Outcomes ; 9(5): 529-536, 2023 08 07.
Article in English | MEDLINE | ID: mdl-36195332

ABSTRACT

AIMS: Standardized data definitions are necessary for the quantification of quality of care and patient outcomes in observational studies and randomised controlled trials (RCTs). The European Unified Registries for Heart Care Evaluation and Randomised Trials (EuroHeart) project of the European Society of Cardiology (ESC) aims to create pan-European data standards for cardiovascular diseases and interventions, including transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: We followed the EuroHeart methodology for cardiovascular data standard development. A Working Group of 29 members representing 12 countries was established and included a patient representative, as well as experts in the management of valvular heart disease from the European Association of Percutaneous Cardiovascular Interventions (EAPCI), the European Association of Cardiovascular Imaging (EACVI) and the Working Group on Cardiovascular Surgery. We conducted a systematic review of the literature and used a modified Delphi method to reach consensus on a final set of variables. For each variable, the Working Group provided a definition, permissible values, and categorized the variable as mandatory (Level 1) or additional (Level 2) based on its clinical importance and feasibility. In total, 93 Level 1 and 113 Level 2 variables were selected, with the level 1 variables providing the dataset for registration of patients undergoing TAVI on the EuroHeart IT platform. CONCLUSION: This document provides details of the EuroHeart data standards for TAVI processes of care and in-hospital outcomes. In the context of EuroHeart, this will facilitate quality improvement, observational research, registry-based RCTs and post-marketing surveillance of devices, and pharmacotherapies. ONE-SENTENCE SUMMARY: The EuroHeart data standards for transcatheter aortic valve implantation (TAVI) are a set of internationally agreed data variables and definitions that once implemented will facilitate improvement of quality of care and outcomes for patients receiving TAVI.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Registries , Randomized Controlled Trials as Topic
15.
Open Heart ; 9(2)2022 10.
Article in English | MEDLINE | ID: mdl-36192035

ABSTRACT

BACKGROUND: There is a paucity of real-world data assessing the association of operator volumes and mortality specific to primary percutaneous coronary intervention (PPCI). METHODS: Demographic, clinical and outcome data for all patients undergoing PPCI in Leeds General Infirmary, UK, between 1 January 2009 and 31 December 2011, and 1 January 2013 and 31 December 2013, were obtained prospectively. Operator volumes were analysed according to annual operator PPCI volume (low volume: 1-54 PPCI per year; intermediate volume: 55-109 PPCI per year; high volume: ≥110 PPCI per year). Cox proportional hazards regression analyses were undertaken to investigate 30-day and 12-month all-cause mortality, adjusting for confounding factors. RESULTS: During this period, 4056 patients underwent PPCI, 3703 (91.3%) of whom were followed up for a minimum of 12 months. PPCI by low-volume operators was associated with significantly higher adjusted 30-day mortality (HR 1.48 (95% CI 1.05 to 2.08); p=0.02) compared with PPCI performed by high-volume operators, with no significant difference in adjusted 12-month mortality (HR 1.26 (95% CI 0.96 to 1.65); p=0.09). Comparisons between low-volume and intermediate-volume operators, and between intermediate and high-volume operators, showed no significant differences in 30-day and 12-month mortality. CONCLUSIONS: Low operator volume is independently associated with higher probability of 30-day mortality compared with high operator volume, suggesting a volume-outcome relationship in PPCI at a threshold higher than current recommendations.


Subject(s)
Myocardial Infarction , Percutaneous Coronary Intervention , Hospital Mortality , Humans , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Retrospective Studies , Treatment Outcome
16.
J Invasive Cardiol ; 33(10): E761-E768, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34521771

ABSTRACT

OBJECTIVES: To assess the impact of balloon use for predilation, valve implantation, or postdilation on in-hospital mortality among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR utilizes self-expanding, mechanically expanding, or balloon-expandable valves. Balloon inflation is inherent to deployment of balloon-expandable valves. Balloons may additionally be used with all valve types for pre- and postdilation. The relationships between valve mechanism, balloon use, and in-hospital mortality are not fully characterized. METHODS: Prospective data were collected on 4063 patients undergoing TAVR for aortic stenosis at 4 high-volume centers in the United Kingdom. In-hospital mortality was analyzed according to valve expansion mechanism, use of balloons for pre- and postdilation, and specific cause of death. RESULTS: Mean patient age was 83 ± 8 years. Implanted valves were self expanding (n = 2241; 55%), mechanically expanding (n = 1092; 27%), or balloon expandable (n = 727; 18%). In-hospital death occurred in 66 cases (1.6%). Thirty-six deaths (54.5%) were classified as implantation-related mortalities, with rates of 0.8%, 0.5%, and 1.7% (P=.04) among self-expanding, mechanically expanding, and balloon-expandable technologies, respectively. Patients who underwent balloon inflation at any stage of their procedure (n = 2556; 63%) had significantly higher implantation-related mortality than those who did not (1.3% vs 0.3%, respectively; P<.01). Balloon-expandable valve procedures were associated with significantly higher all-cause mortality (2.6% vs 1.4%; P=.02) and implantation-related mortality (1.7% vs 0.7%; P=.02) than non-balloon-expandable valve procedures. Balloon-related complications accounted for 18 cases (26%) of total in-hospital mortality, including all 12 cases (17.4%) of annular rupture and 5 cases (7.2%) of coronary occlusion. CONCLUSIONS: Balloon use for predilation, valve implantation, or postdilation was associated with an increased mortality risk. Balloon-related complications were the largest contributor to in-hospital mortality, comprising all cases of annular rupture and the majority of coronary occlusion cases.


Subject(s)
Aortic Valve Stenosis , Balloon Valvuloplasty , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/adverse effects , Heart Valve Prosthesis/adverse effects , Hospital Mortality , Humans , Prospective Studies , Prosthesis Design , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
17.
Open Heart ; 8(1)2021 03.
Article in English | MEDLINE | ID: mdl-33767000

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is a proven treatment for life-threatening aortic valve disease, predominantly severe aortic stenosis. However, even among developed nations, access to TAVI is not uniform. The Valve for Life initiative was launched by the European Association of Percutaneous Cardiovascular Interventions in 2015 with the objective of improving access to transcatheter valve interventions across Europe. The UK has been identified as a country with low penetration of these procedures and has been selected as the fourth nation to be included in the initiative. Specifically, the number of TAVI procedures carried out in the UK is significantly lower than almost all other European nations. Furthermore, there is substantial geographical inequity in access to TAVI within the UK. As a consequence of this underprovision, waiting times for TAVI are long, and mortality among those waiting intervention is significant. This article reviews these issues, reports new data on access to TAVI in the UK and presents the proposals of the UK Valve for Life team to address the current problems in association with the British Cardiovascular Intervention Society.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/epidemiology , Humans , Incidence , Risk Factors , United Kingdom
18.
Catheter Cardiovasc Interv ; 98(3): E444-E452, 2021 09.
Article in English | MEDLINE | ID: mdl-33502784

ABSTRACT

OBJECTIVES: To determine whether a permanent pacemaker (PPM) in situ can enhance survival after transcatheter aortic valve implantation (TAVI), in a predominantly inoperable or high risk cohort. BACKGROUND: New conduction disturbances are the most frequent complication of TAVI, often necessitating PPM implantation before hospital discharge. METHODS: We performed an observational cohort analysis of the UK TAVI registry (2007-2015). Primary and secondary endpoints were 30-day post-discharge all-cause mortality and long-term survival, respectively. RESULTS: Of 8,651 procedures, 6,815 complete datasets were analyzed. A PPM at hospital discharge, irrespective of when implantation occurred (PPM 1.68% [22/1309] vs. no PPM 1.47% [81/5506], odds ratio [OR] 1.14, 95% confidence interval [CI] 0.71-1.84; p = .58), or a PPM implanted peri- or post-TAVI only (PPM 1.44% [11/763] vs. no PPM 1.47% [81/5506], OR 0.98 [0.51-1.85]; p = .95) did not significantly reduce the primary endpoint. Patients with a PPM at discharge were older, male, had right bundle branch block at baseline, were more likely to have received a first-generation self-expandable prosthesis and had experienced more peri- and post-procedural complications including bailout valve-in-valve rescue, bleeding and acute kidney injury. A Cox proportional hazards model demonstrated significantly reduced long-term survival in all those with a PPM, irrespective of implantation timing (hazard ratio [HR] 1.14 [1.02-1.26]; p = .019) and those receiving a PPM only at the time of TAVI (HR 1.15 [1.02-1.31]; p = .032). The reasons underlying this observation warrant further investigation. CONCLUSIONS: A PPM did not confer a survival advantage in the first 30 days after hospital discharge following TAVI.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aftercare , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Male , Patient Discharge , Postoperative Complications , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
JACC Cardiovasc Interv ; 14(2): 172-181, 2021 01 25.
Article in English | MEDLINE | ID: mdl-33478633

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the short-term safety and efficacy of transcatheter aortic valve replacement (TAVR) with the LOTUS Edge system. BACKGROUND: The LOTUS Edge system was commercially re-released in April 2019. The authors report the first European experience with this device. METHODS: A multicenter, single-arm, retrospective registry was initiated to evaluate short-term clinical outcomes. Included cases are the first experience with this device and new implantation technique in Europe. Clinical, echocardiographic, and computed tomographic data were analyzed. Endpoints were defined according to Valve Academic Research Consortium-2 and were site reported. RESULTS: Between April and November 2019, 286 consecutive patients undergoing TAVR with the LOTUS Edge system at 18 European centers were included. The mean age and Society of Thoracic Surgeons score were 81.2 ± 6.9 years and 5.2 ± 5.4%, respectively. Nearly one-half of all patients (47.9%) were considered to have complex anatomy. Thirty-day major adverse events included death (2.4% [n = 7]) and stroke (3.5% [n = 10]). After TAVR, the mean aortic valve area was 1.9 ± 0.9 cm2, and the mean transvalvular gradient was 11.9 ± 5.7 mm Hg. None or trace paravalvular leak (PVL) occurred in 84.4% and moderate PVL in 2.0%. There were no cases of severe PVL. New permanent pacemaker (PPM) implantation was required in 25.9% among all patients and 30.8% among PPM-naive patients. CONCLUSIONS: Early experience with the LOTUS Edge system demonstrated satisfactory short-term safety and efficacy, favorable hemodynamic data, and very low rates of PVL in an anatomically complex cohort. New PPM implantation remained high. Further study will evaluate if increasing operator experience with the device and new implantation technique can reduce the incidence of PPM implantation.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Europe , Humans , Prosthesis Design , Retrospective Studies , Risk Factors , Treatment Outcome
20.
Catheter Cardiovasc Interv ; 97(4): E552-E559, 2021 03.
Article in English | MEDLINE | ID: mdl-32779877

ABSTRACT

OBJECTIVES: We sought to identify baseline demographics and procedural factors that might independently predict in-hospital stroke following transcatheter aortic valve implantation (TAVI). BACKGROUND: Stroke is a recognized, albeit infrequent, complication of TAVI. Established predictors of procedure-related in-hospital stroke; however, remain poorly defined. METHODS: We conducted an observational cohort analysis of the multicenter UK TAVI registry. The primary outcome measure was the incidence of in-hospital stroke. RESULTS: A total of 8,652 TAVI procedures were performed from 2007 to 2015. There were 205 in-hospital strokes reported by participating centers equivalent to an overall stroke incidence of 2.4%. Univariate analysis showed that the implantation of balloon-expandable valves caused significantly fewer strokes (balloon-expandable 96/4,613 [2.08%] vs. self-expandable 95/3,272 [2.90%]; p = .020). After multivariable analysis, prior cerebrovascular disease (CVD) (odds ratio [OR] 1.51, 95% confidence interval [CI 1.05-2.17]; p = .03), advanced age at time of operation (OR 1.02 [0.10-1.04]; p = .05), bailout coronary stenting (OR 5.94 [2.03-17.39]; p = .008), and earlier year of procedure (OR 0.93 [0.87-1.00]; p = .04) were associated with an increased in-hospital stroke risk. There was a reduced stroke risk in those who had prior cardiac surgery (OR 0.62 [0.41-0.93]; p = .01) and a first-generation balloon-expandable valve implanted (OR 0.72 [0.53-0.97]; p = .03). In-hospital stroke significantly increased 30-day (OR 5.22 [3.49-7.81]; p < .001) and 1-year mortality (OR 3.21 [2.15-4.78]; p < .001). CONCLUSIONS: In-hospital stroke after TAVI is associated with substantially increased early and late mortality. Factors independently associated with in-hospital stroke were previous CVD, advanced age, no prior cardiac surgery, and deployment of a predominantly first-generation self-expandable transcatheter heart valve.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cohort Studies , Hospitals , Humans , Stroke/epidemiology , Stroke/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , United Kingdom/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...