ABSTRACT
BACKGROUND: The ASSIST (A multicentre Study in Survivors of type B aortic dissection undergoing Stenting) study compared both 1-year outcomes and evolution of true and false lumen (eg, remodeling) in patients with complicated type B aortic dissection subjected to thoracic endovascular aortic repair (TEVAR) with distal true lumen scaffolding by self-expanding nitinol open stent in comparison with TEVAR alone. METHODS: The ASSIST study was a multicenter prospective single-arm study comparing clinical and imaging data from 39 consecutive patients (59.4 ± 13 years of age) who received TEVAR and the JOTEC E-XL open stent with data from matched control subjects treated with TEVAR alone based on 1:1 propensity score matching. Clinical data were collected by an independent Contract Research Organization (CRO) and computed tomography images were subjected to blinded core-lab analysis. RESULTS: There were no differences in baseline demographics, clinical profiles, morphological data, procedural details, and in-hospital and 1-year outcomes between groups. Differences emerged with regard to evolution of both true lumen distal to stent graft, false lumen over the entire length of dissection, and remodeling (P < .001). At 1 year, TEVAR with the E-XL stent revealed false lumen thrombosis at the level of celiac trunk in 53.8% vs 17.9% with TEVAR alone (P = .004). Kaplan-Meier survival analysis indicated favorable clinical outcomes with the additional E-XL stent. CONCLUSIONS: TEVAR for acute complicated type B aortic dissection proved to be safe and promoted remodeling of the stent grafted thoracic aorta. Additional scaffolding of the true lumen distal to TEVAR with a self-expanding stent supported distal true lumen expansion, false lumen regression, and thrombosis, with evidence of improved distal remodeling at 1 year.
Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Stents , Vascular Remodeling/physiology , Adult , Aged , Aortic Dissection/mortality , Aortic Aneurysm, Thoracic/mortality , Female , Humans , Male , Middle Aged , Prospective StudiesSubject(s)
Computed Tomography Angiography , Coronary Angiography/methods , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Heart Valves/surgery , Multidetector Computed Tomography , Postoperative Complications/diagnostic imaging , Prosthesis Failure , Aged , Echocardiography, Transesophageal , Female , Heart Valves/diagnostic imaging , Heart Valves/physiopathology , Humans , Male , Middle Aged , Postoperative Complications/etiology , Postoperative Complications/physiopathology , Predictive Value of Tests , Retrospective Studies , Treatment OutcomeABSTRACT
OBJECTIVES: To evaluate the effect of a computer-aided detection (CAD) algorithm for coronary CT angiography (cCTA) on the performance of readers with different experience levels. METHODS: We studied 50 patients (18 women, 58 ± 11 years) who had undergone cCTA and quantitative coronary angiography (QCA). Eight observers with varying experience levels evaluated all studies for ≥50 % coronary artery stenosis. After 3 months, the same observers re-evaluated all studies, this time guided by a CAD system. Their performance with and without the CAD system (sensitivity, specificity, positive predictive value and negative predictive value) was assessed using the Likelihood Ratio Χ(2) test both at the per-patient and per-vessel levels. RESULTS: The sensitivity of the CAD system alone for stenosis detection was 71 % per-vessel and 100 % per-patient. There were 54 false positive (FP) findings within 199 analyzed vessels, most of them associated with non-obstructive (<50 %) lesions. With CAD, one (out of three, 33 %) inexperienced reader's per-patient sensitivity and negative predictive value significantly improved from 79 % to 100 % (P = 0.046) and from 90 % to 100 % (P = 0.034), respectively. Other readers' performance indices showed no statistically significant change. CONCLUSIONS: Our results suggest that CAD can improve some inexperienced readers' sensitivity for diagnosing coronary artery stenosis at cCTA.