Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Arch Orthop Trauma Surg ; 140(11): 1767-1774, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32712820

ABSTRACT

INTRODUCTION: Arthroscopic transosseous rotator cuff repair can be performed with an external guide, although the proximity to the axillary nerve raises safety concerns. The aim of this study is to determine the safety of different drilling angles regarding the axillary nerve. MATERIALS AND METHODS: We performed a bone tunnel in the greater tuberosity in 17 fresh frozen shoulders, using an external guide at four different angles: 40°, 50°, 60°, and 70°. At each angle, we measured the distance between the drill and the axillary nerve, the distance from the acromion to the skin incision point, and the perimeter of the arm at the axilla. RESULTS: The distance to the axillary nerve was safe with the guide at an angle of 40°, 50° and 60°, but not at 70° (p = 0.001). We found significant differences between all four angles (p < 0.05). Regression analysis demonstrated the influence of the guide angle in all measurements assessed (p < 0.001). There was no association between the measurements taken and the axillary perimeter (p > 0.5). CONCLUSIONS: Arthroscopic transosseous rotator cuff repair with an external guide does not pose a risk for the axillary nerve using angles of 60° or less.


Subject(s)
Arthroscopy , Peripheral Nerve Injuries/prevention & control , Rotator Cuff/surgery , Shoulder Joint , Arthroscopy/adverse effects , Arthroscopy/methods , Humans , Shoulder Joint/innervation , Shoulder Joint/surgery
2.
Eur J Orthop Surg Traumatol ; 30(7): 1221-1230, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32372118

ABSTRACT

INTRODUCTION: A frequent complication after total hip arthroplasty is bleeding; to reduce it, intravenous or intra-articular tranexamic acid (TXA) is used. There is no evidence yet on which route of administration is better. MATERIALS AND METHOD: This was a prospective, controlled, randomized study in 2 arms between February 2017 and February 2019. In group A, 15 mg/kg intravenous TXA was administered and in group B 2 g intra-articular TXA. Haemoglobin and haematocrit values were evaluated at 24-72 h, also volume of drained blood, volume of blood lost, transfusions and complications. RESULTS: A total of 195 patients were included: 110 in group A and 85 group B. Haemoglobin dropped 3.10 ± 1.32 g/dl in 24 h and 3.63 ± 1.41 g/dl at 72 h in group A; the haematocrit dropped 8.38 ± 4.67% in 24 h and 15.40 ± 4.39% in 72 h. In group B, haemoglobin dropped 3.09 ± 1.40 g/dl in 24 h and 3.34 ± 1.23 g/dl in 72 h and haematocrit 9.75 ± 3.95% and 10.40 ± 3.72% in 24 and 72 h. No significant differences were found for haemoglobin values at 24 and 72 h and haematocrit at 24 h (p > 0.05); we did not obtain statistically significant differences in drainage, blood loss between groups or in the proportion of transfused. When stratifying the results by age, we obtained significant differences in the decrease in haemoglobin (p = 0.021) and haematocrit (p = 0.025) in patients > 65 years. CONCLUSIONS: The different routes of administration of TXA in PTC have a similar effect in reducing post-operative bleeding without evidencing an increase in complications. LEVEL OF EVIDENCE: I.


Subject(s)
Antifibrinolytic Agents , Arthroplasty, Replacement, Hip , Tranexamic Acid , Administration, Intravenous , Arthroplasty, Replacement, Hip/adverse effects , Blood Loss, Surgical/prevention & control , Humans , Infant, Newborn , Postoperative Hemorrhage/etiology , Postoperative Hemorrhage/prevention & control , Prospective Studies
3.
Eur J Orthop Surg Traumatol ; 28(3): 463-469, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29082427

ABSTRACT

PURPOSE: The objective was to assess aseptic complications and functional outcome using a primary total hip arthroplasty with modular neck. METHODS: Prospective cohort of 317 consecutive patients. The mean age was 61.1 (range, 41-84) years. The H-Max-M model (Lima, Italy) system was used in all patients. The functional assessment was made by the Harris Hip Score, Short Form-36 (SF-36), Western Ontario and McMaster Universities Osteoarthritis Index and visual analogue scale for pain. Radiological outcomes were also assessed, and adverse events and complications were noted. RESULTS: The mean follow-up was 6.1 (range, 2-8) years. Functional outcome significantly improved in most patients. There were 3 deep infections (0.9%) and 17 aseptic complications (5.3%) including 1 intraoperative acetabular fracture, 3 later periprosthetic femoral fractures, 1 broken ceramic insert, 1 acetabular loosening, 3 femoral loosening and 1 broken titanium modular neck in a obese patient. No pseudotumors or elevated serum levels of metal ions were found among the patients with radiolucent lines or aseptic loosening. CONCLUSIONS: The findings in the present study showed that the H-MAX-M stem provided satisfactory functional outcome in most patients with a low rate of complications attributable to the modular neck design. We consider that using this novel modular neck-stem coupling design can be an alternative to the conventional monoblock stems in patients without overweight.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Prosthesis Design , Adult , Aged , Aged, 80 and over , Bone Cements , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteoarthritis, Hip/surgery , Patient Safety , Periprosthetic Fractures/etiology , Prospective Studies , Prosthesis Failure/adverse effects , Prosthesis-Related Infections/etiology , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...