Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Clin Med Phys ; 21(7): 11-15, 2020 Jul.
Article in English | MEDLINE | ID: mdl-31800151

ABSTRACT

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. Approved by AAPM's Executive Committee May 28, 2019.


Subject(s)
Health Physics , Radiation Oncology , Humans , Societies , United States
2.
J Appl Clin Med Phys ; 15(2): 4523, 2014 Mar 06.
Article in English | MEDLINE | ID: mdl-24710437

ABSTRACT

The delivery of accurate proton dose for clinical trials requires that the appropriate conversion function from Hounsfield unit (HU) to relative linear stopping power (RLSP) be used in proton treatment planning systems (TPS). One way of verifying that the TPS is calculating the correct dose is an end-to-end test using an anthropomorphic phantom containing tissue equivalent materials and dosimeters. Many of the phantoms in use for such end-to-end tests were originally designed using tissue-equivalent materials that had physical characteristics to match patient tissues when irradiated with megavoltage photon beams. The aim of this study was to measure the RLSP of materials used in the phantoms, as well as alternative materials to enable modifying phantoms for use at proton therapy centers. Samples of materials used and projected for use in the phantoms were measured and compared to the HU assigned by the treatment planning system. A percent difference in RLSP of 5% was used as the cutoff for materials deemed acceptable for use in proton therapy (i.e., proton equivalent). Until proper tissue-substitute materials are identified and incorporated, institutions that conduct end-to-end tests with the phantoms are instructed to override the TPS with the measured stopping powers we provide. To date, the RLSPs of 18 materials have been measured using a water phantom and/or multilayer ion chamber (MLIC). Nine materials were identified as acceptable for use in anthropomorphic phantoms. Some of the failing tissue substitute materials are still used in the current phantoms. Further investigation for additional appropriate tissue substitute materials in proton beams is ongoing. Until all anthropomorphic phantoms are constructed of appropriate materials, a unique HU-RLSP phantom has been developed to be used during site visits to verify the proton facility's treatment planning HU-RLSP calibration curve.


Subject(s)
Phantoms, Imaging , Proton Therapy/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy/instrumentation , Anthropometry , Calibration , Humans , Proton Therapy/methods , Quality Assurance, Health Care , Quality Control , Radiotherapy/methods , Radiotherapy Dosage , Reproducibility of Results , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...