Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Acoust Soc Am ; 153(5): 2826, 2023 05 01.
Article in English | MEDLINE | ID: mdl-37163702

ABSTRACT

Knowledge of the sound pressure transfer to the eardrum is important. The transfer is highly influenced by the shape of the ear canal and its acoustic properties, such as the acoustic impedance at the eardrum. Invasive procedures to measure the sound pressure at the eardrum are usually elaborate or costly. We propose a numerical method to estimate the transfer impedance of the ear canal given only input impedance measurements at the ear canal entrance, by using one-dimensional first-order finite elements and Nelder-Mead optimization algorithm. Estimations on the area function of the ear canal and the acoustic impedance at the eardrum are achieved. Results are validated through numerical simulations on ten different ear canal geometries and three different acoustic impedances at the eardrum, using synthetically generated data from three-dimensional finite element simulations.


Subject(s)
Acoustics , Ear Canal , Electric Impedance , Sound , Tympanic Membrane
2.
J Acoust Soc Am ; 147(1): 85, 2020 01.
Article in English | MEDLINE | ID: mdl-32006989

ABSTRACT

Acoustic feedback in hearing aids occurs due to the coupling between the hearing aid loudspeaker and microphones. In order to reduce acoustic feedback, adaptive filters are often used to estimate the feedback path. To increase the convergence speed and decrease the computational complexity of the adaptive algorithms, it has been proposed to split the acoustic feedback path into a time-invariant fixed part and a time-varying variable part. A key question of this approach is how to determine the fixed part. In this paper, two approaches are investigated: (1) a digital filter design approach that makes use of the signals of at least two hearing aid microphones and (2) a defined physical location approach using an electro-acoustic model and the signals of one hearing aid microphone and an additional ear canal microphone. An experimental comparison using measured acoustic feedback paths showed that both approaches enable one to reduce the number of variable part coefficients. It is shown that individualization of the fixed part increases the performance. Furthermore, the two approaches offer solutions for different requirements on the effort to a specific hearing aid design on the one hand and the effort during the hearing aid fitting on the other hand.


Subject(s)
Hearing Aids , Signal Processing, Computer-Assisted , Acoustic Stimulation , Acoustics , Equipment Design , Feedback , Humans , Models, Biological , Models, Theoretical
3.
J Acoust Soc Am ; 145(2): 917, 2019 02.
Article in English | MEDLINE | ID: mdl-30823792

ABSTRACT

Future hearing systems and hearables will likely contain microphones and receivers in the ear canal. In order to predict the sound pressure at the eardrum in such a scenario, a one-dimensional electroacoustic model of a prototype open earpiece with integrated receivers and integrated microphones was developed. The model parameters were obtained in a training setup with well-defined loads at both sides of the earpiece. Subsequently, the prototype earpiece was put on individual subjects, and the model was then used to determine the acoustic impedance of the ear canal, which in turn was used to derive models of the individual ear canal and eardrum, by minimizing five types of cost functions and various parameters. Model predictions of the sound pressure at the individual eardrum were subsequently compared to probe-tube measurements in 12 human subjects. An analysis of the resulting errors led to identifying the best combination of cost function and associated parameters. This best combination resulted in an agreement between measurement and prediction of less than ±3 dB and ±20° up to 3 kHz and less than ±5 dB and ±30° up to 6-8 kHz, performing significantly better than both average transfer models and existing individualized predictions.


Subject(s)
Hearing Aids , Models, Biological , Tympanic Membrane , Adult , Ear Canal , Equipment Design , Female , Humans , Male , Pressure , Sound , Transducers
4.
J Acoust Soc Am ; 138(4): EL399-404, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26520351

ABSTRACT

A reciprocal measurement procedure to measure the acoustic feedback path in hearing aids is investigated. The advantage of the reciprocal measurement compared to the direct measurement is a significantly reduced sound pressure in the ear. The direct and reciprocal measurements are compared using measurements on a dummy head with adjustable ear canals, different earmolds, and variations in the outer sound field. The results show that the reciprocal measurement procedure can be used to obtain plausible feedback paths, while reducing the sound pressure in the ear canal by 30 to 40 dB.


Subject(s)
Feedback , Hearing Aids , Acoustic Stimulation , Ear Canal , Equipment Design , Humans , Models, Anatomic , Noise , Pressure , Speech Acoustics , Transducers, Pressure
5.
J Acoust Soc Am ; 135(4): 2012-25, 2014 Apr.
Article in English | MEDLINE | ID: mdl-25235000

ABSTRACT

When re-synthesizing individual head related transfer functions (HRTFs) with a microphone array, smoothing HRTFs spectrally and/or spatially prior to the computation of appropriate microphone filters may improve the synthesis accuracy. In this study, the limits of the associated HRTF modifications, until which no perceptual degradations occur, are explored. First, complex spectral smoothing of HRTFs into constant relative bandwidths was considered. As a prerequisite to complex smoothing, the HRTF phase spectra were substituted by linear phases, either for the whole frequency range or above a certain cut-off frequency only. The results indicate that a broadband phase linearization of HRTFs can be perceived for certain directions/subjects and that the thresholds can be predicted by a simple model. HRTF phase spectra can be linearized above 1 kHz without being detectable. After substituting the original phase by a linear phase above 5 kHz, HRTFs may be smoothed complexly into constant relative bandwidths of 1/5 octave, without introducing noticeable artifacts. Second, spatially smoother HRTF directivity patterns were obtained by levelling out spatial notches. It turned out that spatial notches do not have to be retained if they are less than 29 dB below the maximum level in the directivity pattern.

6.
Am J Audiol ; 22(1): 65-73, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23064418

ABSTRACT

PURPOSE: As the form and size of the external auditory canal determine its transmitting function and hence the sound pressure in front of the eardrum, it is important to understand its anatomy in order to develop, optimize, and compare acoustical methods. METHOD: High-resolution computed tomography (HRCT) data were measured retrospectively for 100 patients who had received a cochlear implant. In order to visualize the anatomy of the auditory canal, its length, radius, and the angle at which it runs were determined for the patients' right and left ears. The canal's volume was calculated, and a radius function was created. RESULTS: The determined length of the auditory canal averaged 23.6 mm for the right ear and 23.5 mm for the left ear. The calculated auditory canal volume (Vtotal) was 0.7 ml for the right ear and 0.69 ml for the left ear. The auditory canal was found to be significantly longer in men than in women, and the volume greater. CONCLUSION: The values obtained can be employed to develop a method that represents the shape of the auditory canal as accurately as possible to allow the best possible outcomes for hearing aid fitting.


Subject(s)
Ear Canal/diagnostic imaging , Hearing Aids , Prosthesis Fitting/methods , Adolescent , Adult , Aged , Aged, 80 and over , Cochlear Implants , Ear Canal/physiology , Female , Hearing/physiology , Humans , Male , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed , Young Adult
7.
Inform Health Soc Care ; 35(3-4): 92-103, 2010.
Article in English | MEDLINE | ID: mdl-21133766

ABSTRACT

Worldwide, ageing societies are bringing challenges for independent living and healthcare. Health-enabling technologies for pervasive healthcare and sensor-enhanced health information systems offer new opportunities for care. In order to identify, implement and assess such new information and communication technologies (ICT) the 'Lower Saxony Research Network Design of Environments for Ageing' (GAL) has been launched in 2008 as interdisciplinary research project. In this publication, we inform about the goals and structure of GAL, including first outcomes, as well as to discuss the potentials and possible barriers of such highly interdisciplinary research projects in the field of health-enabling technologies for pervasive healthcare. Although GAL's high interdisciplinarity at the beginning slowed down the speed of research progress, we can now work on problems, which can hardly be solved by one or few disciplines alone. Interdisciplinary research projects on ICT in ageing societies are needed and recommended.


Subject(s)
Aging , Environment Design , Information Systems/organization & administration , Interdisciplinary Communication , Research/organization & administration , Health Services for the Aged/organization & administration , Home Care Services/organization & administration , Humans , Independent Living , Remote Sensing Technology/methods , Social Support
SELECTION OF CITATIONS
SEARCH DETAIL
...