Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 83(8): 083507, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22938294

ABSTRACT

In this work we demonstrate a design for obtaining laser backlighting (e.g., interferometry) and time-resolved extreme ultraviolet self-emission images along the same line-of-sight. This is achieved by modifying a single optical component in the laser collection optics with apertures and pinhole arrangements suitable for single or multiple frame imaging onto a gated detector, such as a microchannel plate. Test results for exploding wire experiments show that machining of the optic does not affect the overall quality of the recovered laser images, and that, even with a multiple frame system, the area sacrificed to achieve collinear imaging is relatively small. The diagnostics can therefore allow direct correlation of laser and self-emission images and their derived quantities, such as electron density in the case of interferometry. Simple methods of image correlation are also demonstrated.

2.
Rev Sci Instrum ; 80(12): 123505, 2009 Dec.
Article in English | MEDLINE | ID: mdl-20059143

ABSTRACT

For the first time, a geometry has been developed to allow for an axial imaging system for wire-array Z-pinch experiments that produce high-resolution x-ray images. The new geometry required a significant redesign of the electrode hardware. Calibrated areal density measurements of the Z-pinch plasma including wire cores, coronal plasma, streaming plasma, and the precursor were obtained. The system used eight-wire molybdenum (Mo) X pinches in series with and directly below the Z-pinch axis to provide micron-scale x-rays sources for point-projection radiography. The images formed on the x-ray sensitive film had a 15 mm diameter field of view at the center height of the array and a magnification of about 7.5:1. Titanium (Ti) filters in front of the film transmitted radiation in the spectral range of 3-5 keV. For calibration, a separate film with the same thickness Ti filter was placed the same distance from the X pinch. This film had an unobstructed path that bypasses the Z-pinch but included step wedges for calibration of the Z-pinch plasma. The step wedges had thicknesses of tungsten (W) ranging from 0.015 to 1.1 microm to obtain areal density measurements of the W plasma from the wire-array. Images had subnanosecond temporal resolution and about 10 microm spatial resolution.

3.
Rev Sci Instrum ; 79(10): 10E316, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044478

ABSTRACT

Some issues concerning high-current electron beam transport from the X pinch cross point to the diagnostic system and measurements of the beam current by Faraday cups are discussed. Results of computer simulation of electron beam propagation from the pinch to the Faraday cup give limits for the measured current for beams having different energy spreads. The beam is partially neutralized as it propagates from the X pinch to a diagnostic system, but within a Faraday cup diagnostic, space charge effects can be very important. Experimental results show evidence of such effects.

SELECTION OF CITATIONS
SEARCH DETAIL
...