Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Respir Care ; 45(4): 390-400, 2000 Apr.
Article in English | MEDLINE | ID: mdl-10780034

ABSTRACT

BACKGROUND: Noninvasive positive pressure ventilation (NPPV) has been studied in several settings and shown to reduce patient morbidity associated with endotracheal intubation. Intolerance to NPPV has been estimated at 25-33%, a substantial proportion of attempts to ventilate noninvasively. Bi-level pressure ventilators (BPVs) have been designed for NPPV, yet their response to changes in respiratory impedance has not been extensively evaluated. To determine responses of BPVs to changing impedance conditions, we tested 4 BPVs to evaluate the potential for intolerance. We also developed a mathematical model for BPV performance that accounted for impedance conditions, leak, pressure settings, and inspiratory flow cutoff level. METHODS: Four BPV models at the same settings were challenged to ventilate a triggered test lung under a range of impedance conditions while measuring tidal volume (VT) and intrinsic positive end-expiratory pressure (auto-PEEP). The model was used to predict VT and auto-PEEP under normal, restrictive, and obstructive conditions. RESULTS: The BPV models tested delivered VT in a similar manner. VT decreased with decreased compliance and increased resistance. Auto-PEEP developed with increased resistance and compliance. The model predicted a VT delivery dependent on inspiratory flow cutoff level. For the obstructive condition, the model predicts an optimal VT delivery within a specific inspiratory flow cutoff range that becomes narrower with increasing resistance. CONCLUSIONS: VT delivery and auto-PEEP generated by BPVs are highly dependent on the prevailing impedance condition. Though there are differences between BPV models, generally, performance was similar between the models tested. This report suggests that knowledge of both respiratory system impedance and the performance of the BPV in use are required to attend to inadequate VT delivery and auto-PEEP generation. Furthermore, the model predicts a relatively narrow range for inspiratory flow cutoff that provides adequate ventilatory support without causing hyperinflation in patients with obstructive conditions.


Subject(s)
Positive-Pressure Respiration/instrumentation , Positive-Pressure Respiration/statistics & numerical data , Respiratory Mechanics/physiology , Ventilators, Mechanical/standards , Humans , Models, Biological
2.
Respir Care ; 45(2): 204-11; discussion 211-3, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10771792

ABSTRACT

The NOTT study showed improved survival in COT patients who received LTOT for longer periods (mean 17.7 h/d, median 19.4 h/d) from an ambulatory oxygen system, compared with the survival of NOT patients who received oxygen for a mean of 11.8 h/d from a stationary system. The differences in survival could have been due to the method or the duration of oxygen therapy, or both. An increase in cardiac output and increased oxygenation of the arterial blood (oxygen content) results in increased tissue oxygen transport. In addition, COT was associated with better survival and reduced hospitalizations, compared with NOT patients who were unable to increase their walking level.


Subject(s)
Ambulatory Care , Lung Diseases, Obstructive/therapy , Oxygen Inhalation Therapy/methods , Walking/physiology , Analysis of Variance , Clinical Trials as Topic , Exercise Tolerance , Humans , Long-Term Care , Lung Diseases, Obstructive/mortality , Lung Diseases, Obstructive/physiopathology , Proportional Hazards Models , Survival Analysis , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...