1.
Phys Med Biol ; 64(7): 075008, 2019 03 27.
Article in English | MEDLINE | ID: mdl-30754030

ABSTRACT

3D breast modelling for 2D and 3D breast x-ray imaging would benefit from the availability of digital and physical phantoms that reproduce accurately the complexity of the breast anatomy. While a number of groups have produced digital phantoms with increasing level of complexity, physical phantoms reproducing that software approach have been scarcely developed. One possibility is offered by 3D printing technology. This implies the assessment of the energy dependent absorption index ß of 3D printing materials for absorption based imaging, as well as the assessment of the refractive index decrement, δ, of the printing material, for phase contrast imaging studies, at the energies of interest for breast imaging. In this work we set-up a procedure and performed a series of measurements (at 30, 45 and 60 keV, at the European Synchrotron Radiation Facility) for assessing the relative value of δ with respect to that of breast tissues, for twelve 3D printing materials. The method included propagation based phase contrast 2D imaging and retrieval of the estimated phase shift map, using the Paganin's algorithm. Breast glandular, adipose and skin tissues were used as reference materials of known ratio δ/ß. A percentage difference Δδ was introduced to assess the suitability of the printing materials as tissue substitutes. The accuracy of the method (about 4%) was assessed based on the properties of PMMA and Nylon, acting as gold standard. Results show that, for the above photon energies, ABS is a good substitute for adipose tissue, Hybrid as a substitute of the glandular tissue and PET-G for simulating the skin. We plan to realize a breast phantom manufactured by fused deposition modelling (FDM) technology using ABS, Hybrid and PET-G as substitutes of the glandular and skin tissue and a second phantom by stereolithography (SLA) technology with the resins Flex, Tough and Black.


Subject(s)
Breast/diagnostic imaging , Microscopy, Phase-Contrast/methods , Phantoms, Imaging , Printing, Three-Dimensional/instrumentation , Refractometry , Software , Adipose Tissue/diagnostic imaging , Female , Humans , Skin/diagnostic imaging
2.
J Xray Sci Technol ; 24(1): 23-41, 2016.
Article in English | MEDLINE | ID: mdl-26890907

ABSTRACT

OBJECTIVE: The aim of this study is to investigate the validity of using the Multiple Projection Algorithm (MPA) for Breast Tomosynthesis (BT) using real projection images acquired with phantoms at a clinical setting. METHODS: The CIRS-BR3D phantom with ranging thicknesses between 3 cm and 6 cm was used for all image quality evaluations. Five sets of measurements were acquired, each comprised of a 2D mammographic image followed by a set of 25 projections within an arc length of 50°. A reconstruction algorithm based on the MPA was adapted for partial isocentric rotation using a stationary detector. For reference purposes, a Back Projection (BP) algorithm was also developed for this geometry. The performance of the algorithms was evaluated, in combination with pre-filtering of the projections, in comparative studies that involved also a comparison between tomosynthesis slices and 2D mammograms. RESULTS: Evaluation of tomosynthesis slices reconstructed with BP and MPA showed close performance for the two algorithms with no considerable differences in feature detection, size and appearance of the background tissue with the MPA running faster the overall process. Pre-filtering of the projections, led to better BT images compared to non-filtering. Increased thickness resulted in limited detection of the features of interest, especially the smaller sized ones. In these cases, the filtered BT slices allowed improved visualization due to removed superimposed tissue compared to the 2D images. The different breast-like slab arrangements in phantoms of the same thickness demonstrated a slight influence on the quality of reconstructed features. CONCLUSIONS: The MPA which had been applied previously to reconstruct tomograms from projections acquired at synchrotron facilities, is a time efficient algorithm, and is fully compliant with and can be successfully used in BT clinical systems. Compared to 2D mammography, BT shows advantage in visualizing features of small size and for increased phantom thickness or features within a dense background with superimposed structures.


Subject(s)
Algorithms , Breast/diagnostic imaging , Mammography/methods , Female , Humans , Image Processing, Computer-Assisted/methods , Phantoms, Imaging
3.
Comput Methods Programs Biomed ; 107(1): 75-83, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22056810

ABSTRACT

Digital tomosynthesis is a method of limited angle reconstruction of tomographic images produced at variable heights, on the basis of a set of angular projections taken in an arc around human anatomy. Reconstructed tomograms from unprocessed original projection images, however, are invariably affected by tomographic noise such as blurred images of objects lying outside the plane of interest and superimposed on the focused image of the fulcrum plane. The present work investigates the performance of two approaches for generation of tomograms with a reduced noise: a generalised post-processing method, based on constructing a noise mask from all planes in the reconstructed volume, and its subsequent subtraction from the in-focus plane and a filtered Multiple Projection Algorithm. The comparison between the two algorithms shows that the first method provides reconstructions with very good quality in case of high contrast features, especially for those embedded into a heterogeneous background.


Subject(s)
Algorithms , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/statistics & numerical data , Artifacts , Breast/anatomy & histology , Breast/pathology , Breast Neoplasms/diagnostic imaging , Female , Humans , Imaging, Three-Dimensional/statistics & numerical data , Mammography/statistics & numerical data , Models, Anatomic , Phantoms, Imaging , Signal Processing, Computer-Assisted
4.
Phys Med Biol ; 48(22): 3699-719, 2003 Nov 21.
Article in English | MEDLINE | ID: mdl-14680268

ABSTRACT

This paper presents a methodology for three-dimensional (3D) computer modelling of the breast, using a combination of 3D geometrical primitives and voxel matrices that can be further subjected to simulated x-ray imaging, to produce synthetic mammograms. The breast phantom is a composite model of the breast and includes the breast surface, the duct system and terminal ductal lobular units. Cooper's ligaments, the pectoral muscle, the 3D mammographic background and breast abnormalities. A second analytical x-ray matter interaction modelling module is used to generate synthetic images from monoenergetic fan beams. Mammographic images of various synthesized breast models differing in size, shape and composition were produced. A preliminary qualitative assessment performed by three radiologists and a quantitative evaluation study using fractal and grey-level histogram analysis were conducted. A comparative study of extracted features with published data has also been performed. The evaluation results indicated good correlation of characteristics between synthetic and actual radiographs. Applications foreseen are not only in the area of breast imaging experimentation but also in education and training.


Subject(s)
Breast/anatomy & histology , Mathematical Computing , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted , Software , Female , Humans , Mammography/instrumentation , Models, Anatomic
5.
Biomed Instrum Technol ; 37(1): 25-33, 2003.
Article in English | MEDLINE | ID: mdl-12613291

ABSTRACT

The evolution of biomedical technology has led to an extraordinary use of medical devices in health care delivery. During the last decade, clinical engineering departments (CEDs) turned toward computerization and application of specific software systems for medical equipment management in order to improve their services and monitor outcomes. Recently, much emphasis has been given to patient safety. Through its Medical Device Directives, the European Union has required all member nations to use a vigilance system to prevent the reoccurrence of adverse events that could lead to injuries or death of patients or personnel as a result of equipment malfunction or improper use. The World Health Organization also has made this issue a high priority and has prepared a number of actions and recommendations. In the present workplace, a new integrated, Windows-oriented system is proposed, addressing all tasks of CEDs but also offering a global approach to their management needs, including vigilance. The system architecture is based on a star model, consisting of a central core module and peripheral units. Its development has been based on the integration of 3 software modules, each one addressing specific predefined tasks. The main features of this system include equipment acquisition and replacement management, inventory archiving and monitoring, follow up on scheduled maintenance, corrective maintenance, user training, data analysis, and reports. It also incorporates vigilance monitoring and information exchange for adverse events, together with a specific application for quality-control procedures. The system offers clinical engineers the ability to monitor and evaluate the quality and cost-effectiveness of the service provided by means of quality and cost indicators. Particular emphasis has been placed on the use of harmonized standards with regard to medical device nomenclature and classification. The system's practical applications have been demonstrated through a pilot evaluation trial.


Subject(s)
Database Management Systems , Documentation/methods , Equipment and Supplies , Information Storage and Retrieval/methods , Software , Systems Integration , Equipment Safety/methods , Management Information Systems , Quality Control , Safety Management/methods , Safety Management/standards