1.
Anal Chim Acta ; 1304: 342556, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38637040

ABSTRACT

BACKGROUND: The on-site and simultaneous determination of anionic nitrite (NO2-) and nitrate (NO3-), and cationic ammonium (NH4+), in industrial and natural waters, presents a significant analytical challenge. Toward this end, herein a 3D-printed micro-reactor with an integrated heater chip was designed and optimised for the post-column colorimetric detection of NH4+ using a modified Berthelot reaction. The system was integrated within a portable and field deployable ion chromatograph (Aquamonitrix) designed to separate and detect NO2- and NO3-, but here enabled with dual LED-based absorbance detectors, with the aim to provide the first system capable of simultaneous determination of both anions and NH4+ in industrial and natural waters. RESULTS: Incorporating a 0.750 mm I.D. 3D-printed serpentine-based microchannel for sample-reagent mixing and heating, the resultant micro-reactor had a total reactor channel length of 1.26 m, which provided for a reaction time of 1.42 min based upon a total flow rate of 0.27 mL min-1, within a 40 mm2 printed area. The colorimetric reaction was performed within the micro-reactor, which was then coupled to a dedicated 660 nm LED-based absorbance detector. By rapidly delivering a reactor temperature of 70 °C in just 40 s, the optimal conditions to improve reaction kinetics were achieved to provide for limits of detection of 0.1 mg L-1 for NH4+, based upon an injection volume of just 10 µL. Linearity for NH4+ was observed over the range 0-50 mg L-1, n = 3, R2 = 0.9987. The reactor was found to deliver excellent reproducibility when included as a post-column reactor within the Aquamonitrix analyser, with an overall relative standard deviation below 1.2 % for peak height and 0.3 % for peak residence time, based upon 6 repeat injections. SIGNIFICANCE: The printed post-column reactor assembly was integrated into a commercial portable ion chromatograph developed for the separation and detection of NO2- and NO3-, thus providing a fully automated system for the remote and simultaneous analysis of NO2-, NO3-, and NH4+ in natural and industrial waters. The fully automated system was deployed externally within a greenhouse facility to demonstrate this capability.

2.
Anal Chim Acta ; 1304: 342557, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38637041

ABSTRACT

BACKGROUND: Nitrite (NO2-) and nitrate (NO3-) can be produced in the distribution systems of chloraminated drinking water due to the nitrification of ammonia. The most applied inorganic chloramine for this purpose, namely monochloramine (NH2Cl), is also released into aquatic environments from water treatment plants' effluent and within industrial waste streams. Within the treatment process, the continuous monitoring of disinfectant levels is necessary to limit the harmful disinfectant by-product (DBP) formation. Currently, NH2Cl can interfere with nutrient analysis in water samples, and there are no analytical techniques available for the simultaneous analysis of NH2Cl, NO2-, and NO3-. RESULTS: A green analytical method based on mixed-mode ion chromatography, specifically ion exchange and ion exclusion modes, was developed for the simultaneous separation and detection of NH2Cl, NO2-, and NO3-. The separation was achieved using a Dionex IonPac AG15 column guard column and a step gradient elution involving deionized water and 120.0 mM NaCl. The method was developed using a benchtop HPLC with a custom-made multi-wavelength UV absorbance detector with a 50-mm flow cell to enable the sensitive detection of NH2Cl, NO2-, and NO3- at 240 nm, 220 nm, and 215 nm, respectively. The developed method was then transferred to a portable ion chromatography (IC) system, the Aquamonitrix analyser. The total run time was less than 10 min for both systems. The benchtop HPLC method had a limit of detection (LOD) of 0.07 µg mL-1 as Cl2 for NH2Cl, 0.01 µg mL-1 for NO2-, and 0.03 µg mL-1 for NO3-. The LODs obtained using the portable Aquamonitrix analyser were found to be 0.36 µg mL-1 as Cl2, 0.02 µg mL-1, and 0.11 µg mL-1 for NH2Cl, NO2-, and NO3-, respectively. Excellent linearity (r ≥ 0.9999) was achieved using the portable analyser over the studied concentration ranges. The developed system was applied to the analysis of spiked municipal drinking water samples and showed excellent repeatability for the three analytes at three different concentration levels (RSD of triplicate recovery experiments ≤ 1.9 %). Moreover, the variation in retention time was negligible for the three target analytes with RSD ≤ 0.8 % over 12 runs. SIGNIFICANCE: We are reporting the first ion chromatographic method for the simultaneous separation and detection of NH2Cl, NO2-, and NO3- in water samples. The monitoring of NH2Cl, NO2-, and NO3- is critical for the determination of disinfectant dosing, water quality, and nitrification status. The developed method can be applied using a benchtop HPLC or via the portable automated IC system to monitor for the three target compounds analysis in water treatment plants.

3.
J Sep Sci ; 45(5): 1042-1050, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34997662

ABSTRACT

An ion chromatography system employing a low-cost three-dimensional printed absorbance detector for indirect ultraviolet detection towards portable phosphate analysis of environmental and industrial waters has been developed. The optical detection cell was fabricated using stereolithography three-dimensional printing of nanocomposite material. Chromatographic analysis and detection of phosphate were carried out using a CS5A 4 × 250 mm analytical column with indirect ultraviolet detection using a 255 nm light-emitting diode. Isocratic elution using a 0.6 mM potassium phthalate eluent combined with 1.44 mM sodium bicarbonate was employed at a flow rate of 0.75 mL/min. A linear calibration range of 0.5 to 30 mg/L PO4 3- applicable to environmental and wastewater analysis was achieved. For retention time and peak area repeatability, relative standard deviation values were 0.68 and 4.09%, respectively. Environmental and wastewater samples were analyzed with the optimized ion chromatography platform and the results were compared to values obtained by an accredited ion chromatograph. For the analysis of environmental samples, relative errors of <14 % were achieved. Recovery analysis was also carried out on both freshwater and wastewater samples and recovery results were within the acceptable range for water analysis using standard ion chromatography methods.