Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 347
Filter
1.
Res Sq ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38883761

ABSTRACT

Background: Little is known about how the brains of autistic children process language during real-world "social contexts," despite the fact that challenges with language, communication, and social interaction are core features of Autism Spectrum Disorder (ASD). Methods: We investigated the neural bases of language processing during social and non-social contexts in a sample of N=20 autistic and N=20 neurotypical (NT) preschool-aged children, 3 to 6 years old. Functional near-infrared spectroscopy (fNIRS) was used to measure children's brain response to "live language" spoken by a live experimenter during an in-person social context (i.e., book reading), and "recorded language" played via an audio recording during a non-social context (i.e., screen time). We examined within-group and between-group differences in the strength and localization of brain response to live language and recorded language, as well as correlations between children's brain response and language skills measured by the Preschool Language Scales. Results: In the NT group, brain response to live language was greater than brain response to recorded language in the right temporal parietal junction (TPJ). In the ASD group, the strength of brain response did not differ between conditions. The ASD group showed greater brain response to recorded language than the NT group in the right inferior and middle frontal gyrus (IMFG). Across groups, children's language skills were negatively associated with brain response to recorded language in the right IMFG, suggesting that processing recorded language required more cognitive effort for children with lower language skills. Children's language skills were also positively associated with the difference in brain response between conditions in the right TPJ, demonstrating that children who showed a greater difference in brain response to live language versus recorded language had higher language skills. Limitations: Findings should be considered preliminary until they are replicated in a larger sample. Conclusions: Findings suggest that the brains of NT children, but not autistic children, process language differently during social and non-social contexts. Individual differences in how the brain processes language during social and non-social contexts may help to explain why language skills are so variable across children with and without autism.

2.
Neurophotonics ; 11(3): 034310, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38881627

ABSTRACT

Significance: Widefield microscopy of the entire dorsal part of mouse cerebral cortex enables large-scale ("mesoscopic") imaging of different aspects of neuronal activity with spectrally compatible fluorescent indicators as well as hemodynamics via oxy- and deoxyhemoglobin absorption. Versatile and cost-effective imaging systems are needed for large-scale, color-multiplexed imaging of multiple fluorescent and intrinsic contrasts. Aim: We aim to develop a system for mesoscopic imaging of two fluorescent and two reflectance channels. Approach: Excitation of red and green fluorescence is achieved through epi-illumination. Hemoglobin absorption imaging is achieved using 525- and 625-nm light-emitting diodes positioned around the objective lens. An aluminum hemisphere placed between objective and cranial window provides diffuse illumination of the brain. Signals are recorded sequentially by a single sCMOS detector. Results: We demonstrate the performance of our imaging system by recording large-scale spontaneous and stimulus-evoked neuronal, cholinergic, and hemodynamic activity in awake, head-fixed mice with a curved "crystal skull" window expressing the red calcium indicator jRGECO1a and the green acetylcholine sensor GRAB ACh 3.0 . Shielding of illumination light through the aluminum hemisphere enables concurrent recording of pupil diameter changes. Conclusions: Our widefield microscope design with a single camera can be used to acquire multiple aspects of brain physiology and is compatible with behavioral readouts of pupil diameter.

3.
Sci Rep ; 14(1): 11915, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38789499

ABSTRACT

Speckle contrast optical spectroscopy (SCOS) is an emerging camera-based technique that can measure human cerebral blood flow (CBF) with high signal-to-noise ratio (SNR). At low photon flux levels typically encountered in human CBF measurements, camera noise and nonidealities could significantly impact SCOS measurement SNR and accuracy. Thus, a guide for characterizing, selecting, and optimizing a camera for SCOS measurements is crucial for the development of next-generation optical devices for monitoring human CBF and brain function. Here, we provide such a guide and illustrate it by evaluating three commercially available complementary metal-oxide-semiconductor cameras, considering a variety of factors including linearity, read noise, and quantization distortion. We show that some cameras that are well-suited for general intensity imaging could be challenged in accurately quantifying spatial contrast for SCOS. We then determine the optimal operating parameters for the preferred camera among the three and demonstrate measurement of human CBF with this selected low-cost camera. This work establishes a guideline for characterizing and selecting cameras as well as for determining optimal parameters for SCOS systems.


Subject(s)
Cerebrovascular Circulation , Signal-To-Noise Ratio , Spectrum Analysis , Humans , Cerebrovascular Circulation/physiology , Spectrum Analysis/methods , Spectrum Analysis/instrumentation , Brain/diagnostic imaging , Brain/physiology , Brain/blood supply
4.
bioRxiv ; 2024 May 16.
Article in English | MEDLINE | ID: mdl-38798389

ABSTRACT

Significance: Accurate sensor placement is vital for non-invasive brain imaging, particularly for functional near infrared spectroscopy (fNIRS) and diffuse optical tomography (DOT), which lack standardized layouts like EEG. Custom, manually prepared probe layouts on textile caps are often imprecise and labor-intensive. Aim: We introduce a method for creating personalized, 3D-printed headgear, enabling accurate translation of 3D brain coordinates to 2D printable panels for custom fNIRS and EEG sensor layouts, reducing costs and manual labor. Approach: Our approach uses atlas-based or subject-specific head models and a spring-relaxation algorithm for flattening 3D coordinates onto 2D panels, using 10-5 EEG coordinates for reference. This process ensures geometrical fidelity, crucial for accurate probe placement. Probe geometries and holder types are customizable and printed directly on the cap, making the approach agnostic to instrument manufacturers and probe types. Results: Our ninjaCap method offers 2.2±1.5 mm probe placement accuracy. Over the last five years, we have developed and validated this approach with over 50 cap models and 500 participants. A cloud-based ninjaCap generation pipeline along with detailed instructions is now available at openfnirs.org. Conclusions: The ninjaCap marks a significant advancement in creating individualized neuroimaging caps, reducing costs and labor while improving probe placement accuracy, thereby reducing variability in research.

5.
Res Sq ; 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38562721

ABSTRACT

A major challenge in neuroscience is to visualize the structure of the human brain at different scales. Traditional histology reveals micro- and meso-scale brain features, but suffers from staining variability, tissue damage and distortion that impedes accurate 3D reconstructions. Here, we present a new 3D imaging framework that combines serial sectioning optical coherence tomography (S-OCT) with a deep-learning digital staining (DS) model. We develop a novel semi-supervised learning technique to facilitate DS model training on weakly paired images. The DS model performs translation from S-OCT to Gallyas silver staining. We demonstrate DS on various human cerebral cortex samples with consistent staining quality. Additionally, we show that DS enhances contrast across cortical layer boundaries. Furthermore, we showcase geometry-preserving 3D DS on cubic-centimeter tissue blocks and visualization of meso-scale vessel networks in the white matter. We believe that our technique offers the potential for high-throughput, multiscale imaging of brain tissues and may facilitate studies of brain structures.

7.
Biomed Opt Express ; 15(2): 579-593, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38404305

ABSTRACT

Dynamic light scattering (DLS) and laser speckle contrast imaging (LSCI) are closely related techniques that exploit the statistics of speckle patterns, which can be utilized to measure cerebral blood flow (CBF). Conventionally, the temporal speckle intensity auto-correlation function g2t(τ) is calculated in DLS, while the spatial speckle contrast Ks is calculated in LSCI measurements. Due to the rapid development of CMOS detection technology with increased camera frame rates while still maintaining a large number of pixels, the ensemble or spatial average of g2s(τ) as well as the temporal contrast Kt can be easily calculated and utilized to quantify CBF. Although many models have been established, a proper summary is still lacking to fully characterize DLS and LSCI measurements for spatial and temporal statistics, laser coherence properties, various motion types, etc. As a result, there are many instances where theoretical models are misused. For instance, mathematical formulas derived in the diffusive regime or for ergodic systems are sometimes applied to small animal brain measurements, e.g., mice brains, where the assumptions are not valid. Therefore, we aim to provide a review of the speckle theory for both DLS and LSCI measurements with detailed derivations from first principles, taking into account non-ergodicity, spatial and temporal statistics of speckles, scatterer motion types, and laser coherence properties. From these calculations, we elaborate on the differences between spatial and temporal averaging for DLS and LSCI measurements that are typically ignored but can result in inaccurate measurements of blood flow, particularly the spatially varying nature of the static component in g2t(τ) and Kt. We also obtained g2s(τ) maps in in vivo mouse brain measurements using high frame rate CMOS cameras which have not been demonstrated before, and compared with g2t(τ) and Ks,t. This work provides a useful guide for choosing the correct model to analyze spatial and temporal speckle statistics in in-vivo DLS and LSCI measurements.

8.
bioRxiv ; 2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38328139

ABSTRACT

When analyzing complex scenes, humans often focus their attention on an object at a particular spatial location. The ability to decode the attended spatial location would facilitate brain computer interfaces for complex scene analysis (CSA). Here, we investigated capability of functional near-infrared spectroscopy (fNIRS) to decode audio-visual spatial attention in the presence of competing stimuli from multiple locations. We targeted dorsal frontoparietal network including frontal eye field (FEF) and intra-parietal sulcus (IPS) as well as superior temporal gyrus/planum temporal (STG/PT). They all were shown in previous functional magnetic resonance imaging (fMRI) studies to be activated by auditory, visual, or audio-visual spatial tasks. To date, fNIRS has not been applied to decode auditory and visual-spatial attention during CSA, and thus, no such dataset exists yet. This report provides an open-access fNIRS dataset that can be used to develop, test, and compare machine learning algorithms for classifying attended locations based on the fNIRS signals on a single trial basis.

9.
Article in English | MEDLINE | ID: mdl-38415197

ABSTRACT

Over the past two decades Biomedical Engineering has emerged as a major discipline that bridges societal needs of human health care with the development of novel technologies. Every medical institution is now equipped at varying degrees of sophistication with the ability to monitor human health in both non-invasive and invasive modes. The multiple scales at which human physiology can be interrogated provide a profound perspective on health and disease. We are at the nexus of creating "avatars" (herein defined as an extension of "digital twins") of human patho/physiology to serve as paradigms for interrogation and potential intervention. Motivated by the emergence of these new capabilities, the IEEE Engineering in Medicine and Biology Society, the Departments of Biomedical Engineering at Johns Hopkins University and Bioengineering at University of California at San Diego sponsored an interdisciplinary workshop to define the grand challenges that face biomedical engineering and the mechanisms to address these challenges. The Workshop identified five grand challenges with cross-cutting themes and provided a roadmap for new technologies, identified new training needs, and defined the types of interdisciplinary teams needed for addressing these challenges. The themes presented in this paper include: 1) accumedicine through creation of avatars of cells, tissues, organs and whole human; 2) development of smart and responsive devices for human function augmentation; 3) exocortical technologies to understand brain function and treat neuropathologies; 4) the development of approaches to harness the human immune system for health and wellness; and 5) new strategies to engineer genomes and cells.

10.
Neuron ; 112(6): 909-923.e9, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38242115

ABSTRACT

Neural population dynamics relevant to behavior vary over multiple spatial and temporal scales across three-dimensional volumes. Current optical approaches lack the spatial coverage and resolution necessary to measure and manipulate naturally occurring patterns of large-scale, distributed dynamics within and across deep brain regions such as the striatum. We designed a new micro-fiber array approach capable of chronically measuring and optogenetically manipulating local dynamics across over 100 targeted locations simultaneously in head-fixed and freely moving mice, enabling the investigation of cell-type- and neurotransmitter-specific signals over arbitrary 3D volumes at a spatial resolution and coverage previously inaccessible. We applied this method to resolve rapid dopamine release dynamics across the striatum, revealing distinct, modality-specific spatiotemporal patterns in response to salient sensory stimuli extending over millimeters of tissue. Targeted optogenetics enabled flexible control of neural signaling on multiple spatial scales, better matching endogenous signaling patterns, and the spatial localization of behavioral function across large circuits.


Subject(s)
Brain , Dopamine , Mice , Animals , Brain/physiology , Corpus Striatum , Neostriatum , Optogenetics/methods
11.
Neurophotonics ; 11(1): 015004, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38282721

ABSTRACT

Significance: The non-invasive measurement of cerebral blood flow based on diffuse optical techniques has seen increased interest as a research tool for cerebral perfusion monitoring in critical care and functional brain imaging. Diffuse correlation spectroscopy (DCS) and speckle contrast optical spectroscopy (SCOS) are two such techniques that measure complementary aspects of the fluctuating intensity signal, with DCS quantifying the temporal fluctuations of the signal and SCOS quantifying the spatial blurring of a speckle pattern. With the increasing interest in the use of these techniques, a thorough comparison would inform new adopters of the benefits of each technique. Aim: We systematically evaluate the performance of DCS and SCOS for the measurement of cerebral blood flow. Approach: Monte Carlo simulations of dynamic light scattering in an MRI-derived head model were performed. For both DCS and SCOS, estimates of sensitivity to cerebral blood flow changes, coefficient of variation of the measured blood flow, and the contrast-to-noise ratio of the measurement to the cerebral perfusion signal were calculated. By varying complementary aspects of data collection between the two methods, we investigated the performance benefits of different measurement strategies, including altering the number of modes per optical detector, the integration time/fitting time of the speckle measurement, and the laser source delivery strategy. Results: Through comparison across these metrics with simulated detectors having realistic noise properties, we determine several guiding principles for the optimization of these techniques and report the performance comparison between the two over a range of measurement properties and tissue geometries. We find that SCOS outperforms DCS in terms of contrast-to-noise ratio for the cerebral blood flow signal in the ideal case simulated here but note that SCOS requires careful experimental calibrations to ensure accurate measurements of cerebral blood flow. Conclusion: We provide design principles by which to evaluate the development of DCS and SCOS systems for their use in the measurement of cerebral blood flow.

12.
IEEE Trans Med Imaging ; 43(2): 638-648, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37703138

ABSTRACT

We introduce an ultrasound speckle decorrelation-based time-lagged functional ultrasound technique (tl-fUS) for the quantification of the relative changes in cerebral blood flow speed (rCBF [Formula: see text]), cerebral blood volume (rCBV) and cerebral blood flow (rCBF) during functional stimulations. Numerical simulations, phantom validations, and in vivo mouse brain experiments were performed to test the capability of tl-fUS to parse out and quantify the ratio change of these hemodynamic parameters. The blood volume change was found to be more prominent in arterioles compared to venules and the peak blood flow changes were around 2.5 times the peak blood volume change during brain activation, agreeing with previous observations in the literature. The tl-fUS shows the ability of distinguishing the relative changes of rCBFspeed, rCBV, and rCBF, which can inform specific physiological interpretations of the fUS measurements.


Subject(s)
Brain Neoplasms , Hemodynamics , Animals , Mice , Blood Volume , Ultrasonography , Brain/diagnostic imaging , Cerebrovascular Circulation , Magnetic Resonance Imaging/methods
13.
bioRxiv ; 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-37986755

ABSTRACT

SIGNIFICANCE: Widefield microscopy of the entire dorsal part of mouse cerebral cortex enables large-scale (mesoscopic) imaging of neuronal activity with fluorescent indicators as well as hemodynamics via oxy- and deoxyhemoglobin absorption. Versatile and cost-effective imaging systems are needed for large-scale, color-multiplexed imaging of multiple fluorescent and intrinsic contrasts. AIM: Develop a system for mesoscopic imaging of two fluorescent and two reflectance channels. APPROACH: Excitation of red and green fluorescence is achieved through epi-illumination. Hemoglobin absorption imaging is achieved using 525- and 625nm LEDs positioned around the objective lens. An aluminum hemisphere placed between objective and cranial window provides diffuse illumination of the brain. Signals are recorded sequentially by a single sCMOS detector. RESULTS: We demonstrate performance of our imaging system by recording large-scale spontaneous and stimulus-evoked neuronal, cholinergic, and hemodynamic activity in awake head-fixed mice with a curved crystal skull window expressing the red calcium indicator jRGECO1a and the green acetylcholine sensor GRABACh3.0 . Shielding of illumination light through the aluminum hemisphere enables concurrent recording of pupil diameter changes. CONCLUSIONS: Our widefield microscope design with single camera can be used to acquire multiple aspects of brain physiology and is compatible with behavioral readouts of pupil diameter.

14.
bioRxiv ; 2023 Nov 17.
Article in English | MEDLINE | ID: mdl-38014018

ABSTRACT

Neural population dynamics relevant for behavior vary over multiple spatial and temporal scales across 3-dimensional volumes. Current optical approaches lack the spatial coverage and resolution necessary to measure and manipulate naturally occurring patterns of large-scale, distributed dynamics within and across deep brain regions such as the striatum. We designed a new micro-fiber array and imaging approach capable of chronically measuring and optogenetically manipulating local dynamics across over 100 targeted locations simultaneously in head-fixed and freely moving mice. We developed a semi-automated micro-CT based strategy to precisely localize positions of each optical fiber. This highly-customizable approach enables investigation of multi-scale spatial and temporal patterns of cell-type and neurotransmitter specific signals over arbitrary 3-D volumes at a spatial resolution and coverage previously inaccessible. We applied this method to resolve rapid dopamine release dynamics across the striatum volume which revealed distinct, modality specific spatiotemporal patterns in response to salient sensory stimuli extending over millimeters of tissue. Targeted optogenetics through our fiber arrays enabled flexible control of neural signaling on multiple spatial scales, better matching endogenous signaling patterns, and spatial localization of behavioral function across large circuits.

15.
Biomed Opt Express ; 14(11): 5946-5964, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-38021128

ABSTRACT

The combination of polarization-sensitive optical coherence tomography (PS-OCT) and birefringence microscopy (BRM) enables multiscale assessment of myelinated axons in postmortem brain tissue, and these tools are promising for the study of brain connectivity and organization. We demonstrate label-free imaging of myelin structure across the mesoscopic and microscopic spatial scales by performing serial-sectioning PS-OCT of a block of human brain tissue and periodically sampling thin sections for high-resolution imaging with BRM. In co-registered birefringence parameter maps, we observe good correspondence and demonstrate that BRM enables detailed validation of myelin (hence, axonal) organization, thus complementing the volumetric information content of PS-OCT.

16.
Adv Sci (Weinh) ; 10(35): e2303381, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37882348

ABSTRACT

The study of aging and neurodegenerative processes in the human brain requires a comprehensive understanding of cytoarchitectonic, myeloarchitectonic, and vascular structures. Recent computational advances have enabled volumetric reconstruction of the human brain using thousands of stained slices, however, tissue distortions and loss resulting from standard histological processing have hindered deformation-free reconstruction. Here, the authors describe an integrated serial sectioning polarization-sensitive optical coherence tomography (PSOCT) and two photon microscopy (2PM) system to provide label-free multi-contrast imaging of intact brain structures, including scattering, birefringence, and autofluorescence of human brain tissue. The authors demonstrate high-throughput reconstruction of 4 × 4 × 2cm3 sample blocks and simple registration between PSOCT and 2PM images that enable comprehensive analysis of myelin content, vascular structure, and cellular information. The high-resolution 2PM images provide microscopic validation and enrichment of the cellular information provided by the PSOCT optical properties on the same sample, revealing the densely packed fibers, capillaries, and lipofuscin-filled cell bodies in the cortex and white matter. It is  shown that the imaging system enables quantitative characterization of various pathological features in aging process, including myelin degradation, lipofuscin accumulation, and microvascular changes, which opens up numerous opportunities in the study of neurodegenerative diseases in the future.


Subject(s)
Microscopy , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Microscopy/methods , Lipofuscin , Brain/diagnostic imaging , Neuroimaging
17.
Biomed Opt Express ; 14(9): 4790-4799, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37791271

ABSTRACT

Laser speckle contrast imaging (LSCI) measures 2D maps of cerebral blood flow (CBF) in small animal brains such as mice. The contrast measured in LSCI also includes the static and slow-varying components that contain information about brain tissue dynamics. But these components are less studied as compared to the fast dynamics of CBF. In traditional wide-field LSCI, the contrast measured in the tissue is largely contaminated by neighboring blood vessels, which reduces the sensitivity to these static and slow components. Our goal is to enhance the sensitivity of the contrast to static and slow tissue dynamics and test models to quantify the characteristics of these components. To achieve this, we have developed a short-separation speckle contrast optical spectroscopy (ss-SCOS) system by implementing point illumination and point detection using multi-mode fiber arrays to enhance the static and slow components in speckle contrast measurements as compared to traditional wide-field LSCI (WF-LSCI). We observed larger fractions of the static and slow components when measured in the tissue using ss-SCOS than in traditional LSCI for the same animal and region of interest. We have also established models to obtain the fractions of the static and slow components and quantify the decorrelation time constants of the intensity auto-correlation function for both fast blood flow and slower tissue dynamics. Using ss-SCOS, we demonstrate the variations of fast and slow brain dynamics in animals before and post-stroke, as well as within an hour post-euthanasia. This technique establishes the foundation to measure brain tissue dynamics other than CBF, such as intracellular motility.

18.
Sci Adv ; 9(41): eadg3844, 2023 10 13.
Article in English | MEDLINE | ID: mdl-37824623

ABSTRACT

Brain cells are arranged in laminar, nuclear, or columnar structures, spanning a range of scales. Here, we construct a reliable cell census in the frontal lobe of human cerebral cortex at micrometer resolution in a magnetic resonance imaging (MRI)-referenced system using innovative imaging and analysis methodologies. MRI establishes a macroscopic reference coordinate system of laminar and cytoarchitectural boundaries. Cell counting is obtained with a digital stereological approach on the 3D reconstruction at cellular resolution from a custom-made inverted confocal light-sheet fluorescence microscope (LSFM). Mesoscale optical coherence tomography enables the registration of the distorted histological cell typing obtained with LSFM to the MRI-based atlas coordinate system. The outcome is an integrated high-resolution cellular census of Broca's area in a human postmortem specimen, within a whole-brain reference space atlas.


Subject(s)
Broca Area , Cerebral Cortex , Humans , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Brain Mapping
19.
Sci Rep ; 13(1): 17970, 2023 10 20.
Article in English | MEDLINE | ID: mdl-37864006

ABSTRACT

Laser speckle contrast imaging (LSCI) is a rapidly developing technology broadly applied for the full-field characterization of tissue perfusion. Over the recent years, significant advancements have been made in interpreting LSCI measurements and improving the technique's accuracy. On the other hand, the method's precision has yet to be studied in detail, despite being as important as accuracy for many biomedical applications. Here we combine simulation, theory and animal experiments to systematically evaluate and re-analyze the role of key factors defining LSCI precision-speckle-to-pixel size ratio, polarisation, exposure time and camera-related noise. We show that contrary to the established assumptions, smaller speckle size and shorter exposure time can improve the precision, while the camera choice is less critical and does not affect the signal-to-noise ratio significantly.


Subject(s)
Laser Speckle Contrast Imaging , Upper Extremity , Animals , Computer Simulation , Laser-Doppler Flowmetry/methods , Regional Blood Flow
20.
Neurophotonics ; 10(3): 035009, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37705938

ABSTRACT

Significance: Brief disruptions in capillary flow, commonly referred to as capillary "stalling," have gained interest recently for their potential role in disrupting cerebral blood flow and oxygen delivery. Approaches to studying this phenomenon have been hindered by limited volumetric imaging rates and cumbersome manual analysis. The ability to precisely and efficiently quantify the dynamics of these events will be key in understanding their potential role in stroke and neurodegenerative diseases, such as Alzheimer's disease. Aim: Our study aimed to demonstrate that the fast volumetric imaging rates offered by Bessel beam two-photon microscopy combined with improved data analysis throughput allows for faster and more precise measurement of capillary stall dynamics. Results: We found that while our analysis approach was unable to achieve full automation, we were able to cut analysis time in half while also finding stalling events that were missed in traditional blind manual analysis. The resulting data showed that our Bessel beam system was captured more stalling events compared to optical coherence tomography, particularly shorter stalling events. We then compare differences in stall dynamics between a young and old group of mice as well as a demonstrate changes in stalling before and after photothrombotic model of stroke. Finally, we also demonstrate the ability to monitor arteriole dynamics alongside stall dynamics. Conclusions: Bessel beam two-photon microscopy combined with high throughput analysis is a powerful tool for studying capillary stalling due to its ability to monitor hundreds of capillaries simultaneously at high frame rates.

SELECTION OF CITATIONS
SEARCH DETAIL
...