Pediatr Cardiol ; 38(2): 215-227, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27847970

ABSTRACT

In August 2010, the Nit-Occlud® Lê (EUREVECO) became available for transcatheter coil occlusion of ventricular septal defects (VSDs). Retrospective European Registry for VSD Closure using the Nit-Occlud® Lê-VSD-Coil; analysis of the feasibility, results, safety and follow-up of VSD-closure over a 3-year period in 18 European centers. In 102 of 111 patients (female 66), successful VSD closure was performed (mean age 8.2 years, mean weight 28.82 kg), 81 perimembranous VSDs (48 with aneurysm), 30 muscular VSDs, mean procedure time was 121.1 min, and mean fluoroscopy time was 26.3 min. Short- and midterm term follow-up was possible in 100/102 patients, there was 1 embolization and 1 explantation after 24 months. Immediate complete closure occurred in 49 of 101 patients (48.5%), trivial residual shunt was present in 51 (50.0%), closure rate was 95% after 6 months and 97% after 1 year. Out of the 102 patients, there were 2 severe complications (1.8%) (1 severe hemolysis, 1 embolization) and 8 moderate/transient (=7.2%) including 1 transient AV block. During a mean follow-up period of 31.3 months (range 24-48) and a total follow-up time of 224.75 patient years, no further problems occurred. VSD closure with the Nit-Occlud® Lê VSD coil is feasible and safe with a minimal risk of severe side effects. The long-term effects and safety require further clinical follow-up studies.


Subject(s)
Cardiac Catheterization/methods , Fluoroscopy , Heart Septal Defects, Ventricular/therapy , Hemolysis , Septal Occluder Device , Adolescent , Child , Child, Preschool , Europe , Female , Heart Septal Defects, Ventricular/classification , Humans , Infant , Male , Operative Time , Registries , Retrospective Studies , Treatment Outcome
2.
Int J Cardiol ; 189: 124-31, 2015.
Article in English | MEDLINE | ID: mdl-25889442

ABSTRACT

OBJECTIVES: We examined interventionally implanted valved Melody conduits after surgical explantation by means of histology and immunohistochemistry and matched these findings with clinical data in order to assess in vivo biocompatibility and to identify risk factors for graft failure. METHODS: 9 Melody valves had been implanted in 8 patients (pulmonary n = 7, tricuspid position n = 1). Indication for explantation included significant obstruction in 7 patients and valve insufficiency in 1 patient. 4 of 8 patients had suffered from endocarditis. Mean interval between implantation and explantation was 3.2 (1.8-5.2) years. All explants were worked up using a uniform protocol with fixation in formalin and embedding in methylmethacrylate. RESULTS: All but one valve of the explanted Melody grafts were thin and histologically intact without any pathological findings. Complete neo-endothelialization could be demonstrated by means of immunohistochemistry. All 4 Melody valves from patients with endocarditis showed dense granulocytic infiltrations, 3 of these showed thrombotic material within the valves. CONCLUSION: This report covers the first series of explanted Melody valves from humans applying a uniform protocol for histopathological examination. Good biocompatibility of the Melody valves could be demonstrated after a mid-term follow-up. Factors for graft failure included endocarditis, outgrowth, and residual stenosis. These findings may have significant implications for the implant procedure as well as care of the patients during long-term follow-up.


Subject(s)
Bioprosthesis , Equipment Failure Analysis/methods , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve Insufficiency/surgery , Prosthesis Failure , Pulmonary Valve Insufficiency/surgery , Adolescent , Adult , Cardiac Catheterization/methods , Child , Device Removal , Female , Follow-Up Studies , Heart Defects, Congenital/pathology , Heart Defects, Congenital/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Immunohistochemistry , Male , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/pathology , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/pathology , Reoperation , Retrospective Studies , Sampling Studies , Time Factors , Ultrasonography , Young Adult