Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
Add more filters










Publication year range
1.
Physiol Rep ; 12(5): e15942, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38439743

ABSTRACT

Reducing proteinuria is a crucial approach in preventing kidney function loss. Previous preclinical studies indicated that caloric restriction (CR) imposed at a young age protects against age-related proteinuria. However, these studies have not explored CR in established renal disease. Therefore, this study aimed to investigate the impact of CR on established proteinuria. Rats, aged 12 ± 2 weeks, were administered 2.1 mg/kg of Adriamycin. Six weeks after injection, protein excretion was measured, and a [13 N]ammonia positron emission tomography (PET) scan was conducted to assess kidney perfusion. After 7 weeks rats were divided into four groups: ad libitum (AL) and CR groups fed either a 12% or a 20% protein diet. All groups were treated for 12 weeks. Blood pressure was measured and a second PET scan was acquired at the end of the study. The animals subjected to CR exhibited a 20.3% decrease in protein excretion (p = 0.003) compared to those in the AL groups. Additionally, blood pressure in the CR group was 21.2% lower (p < 0.001) than in the AL groups. While kidney function declined over time in all groups, the 20% CR group demonstrated the smallest decline. Thus CR effectively reduces urinary protein excretion and lowers blood pressure in rats with established proteinuria.


Subject(s)
Caloric Restriction , Kidney Diseases , Male , Animals , Rats , Proteinuria , Blood Pressure , Ammonia
2.
Atherosclerosis ; : 117199, 2023 Jul 29.
Article in English | MEDLINE | ID: mdl-37550141

ABSTRACT

BACKGROUND AND AIMS: Sodium [18F]fluoride (Na [18F]F) positron emission tomography imaging allows detailed visualization of early arterial micro-calcifications. This study aims to investigate atherosclerosis manifested by micro-calcification, macro-calcification, and aortic stiffness in patients with type 2 diabetes mellitus (T2DM) with and without albuminuria and severely decreased kidney function. METHODS: A cohort was stratified in four groups (N = 10 per group), based on KDIGO categories (G1-5 A1-3). G1-2A1 non-diabetic controls (median [IQR] estimated glomerular filtration rate (eGFR) in mL/min/1.73 m2 91 [81-104]), G1-2A1 with T2DM (eGFR 87 [84-93], and albumin-creatinin-ratio (ACR) in mg/mmol 0.35 [0.25-0.75]), G1-2A3 with T2DM (eGFR 85 [60-103], and ACR 74 [62-122], and G4A3 with T2DM (eGFR 19 [13-27] and ACR 131 [59-304]). RESULTS: Na [18F]F femoral artery grading score differed significantly in the groups with the highest Na [18F]F activity in A3 groups with T2DM (G1-2A3 with T2DM 228 [100-446] and G4A3 with T2DM 198 [113-578]) from the lowest groups of the G1-2A1 with T2DM (33 [0-93]) and in G1-2A1 non-diabetic controls (75 [0-200], p = 0.001). Aortic Na [18F]F activity and femoral artery computed tomography (CT)-assessed macro-calcification was increased in G4A3 with T2DM compared with G1-2A1 with T2DM (47.5 [33.8-73.8] vs. 17.5 [8.8-27.5] (p = 0.006) and 291 [170-511] vs. 12.2 [1.41-44.3] mg (p = 0.032), respectively). Carotid-femoral pulse wave velocity (PWV)-assessed aortic stiffness was significantly higher in both A3 groups with T2DM compared with G1-2A1 with T2DM (11.15 and 12.35 vs. 8.86 m/s, respectively (p = 0.009)). CONCLUSIONS: This study indicates that the presence of severely increased albuminuria in patients with T2DM is cross-sectionally associated with subclinical arterial disease in terms of micro-calcification and aortic stiffness. Additional decrease in kidney function was associated with advanced macro-calcifications.

3.
Eur J Nucl Med Mol Imaging ; 48(13): 4272-4292, 2021 12.
Article in English | MEDLINE | ID: mdl-34633509

ABSTRACT

PURPOSE: The aim of this review is to give an overview of the current status of targeted optical fluorescence imaging in the field of oncology, cardiovascular, infectious and inflammatory diseases to further promote clinical translation. METHODS: A meta-narrative approach was taken to systematically describe the relevant literature. Consecutively, each field was assigned a developmental stage regarding the clinical implementation of optical fluorescence imaging. RESULTS: Optical fluorescence imaging is leaning towards clinical implementation in gastrointestinal and head and neck cancers, closely followed by pulmonary, neuro, breast and gynaecological oncology. In cardiovascular and infectious disease, optical imaging is in a less advanced/proof of concept stage. CONCLUSION: Targeted optical fluorescence imaging is rapidly evolving and expanding into the clinic, especially in the field of oncology. However, the imaging modality still has to overcome some major challenges before it can be part of the standard of care in the clinic, such as the provision of pivotal trial data. Intensive multidisciplinary (pre-)clinical joined forces are essential to overcome the delivery of such compelling phase III registration trial data and subsequent regulatory approval and reimbursement hurdles to advance clinical implementation of targeted optical fluorescence imaging as part of standard practice.


Subject(s)
Fluorescence , Optical Imaging , Cardiology , Forecasting , Humans , Infectious Disease Medicine , Inflammation , Medical Oncology
4.
EJNMMI Radiopharm Chem ; 5(1): 12, 2020 May 14.
Article in English | MEDLINE | ID: mdl-32410136

ABSTRACT

BACKGROUND: The introduction of a GMP-certified 68Ga-generator spurred the application of 68Ga-radiopharmaceuticals. Several radiosynthesis of 68Ga-radiopharmaceuticals are more efficient and robust when performed with 2-[4-(2-hydroxyethyl)piperazin-1-yl] ethanesulfonic acid (HEPES) buffer, which is considered as an impurity in the quality control (QC) procedure. Thus, prior to clinical use, QC must be conducted to ensure that HEPES does not exceed the maximum dose of 200 µg/V Injected as described in European Pharmacopoeia (Ph Eur) for edotreotide. However, when applying the thin-layer chromatography (TLC) method described in the Ph Eur to quantify the HEPES amount present in the 68Ga-octreotide or in the remaining 68Ga-radiopharmaceuticals that were tested, no amount was detectable after 4 min of iodine incubation. Here we tested our modified TLC method and validate a new high-performance liquid chromatography (HPLC) method to quantify HEPES in 68Ga-radiopharmaceuticals and compare it to the TLC-method described in Ph Eur. In addition, samples collected from various institutes were tested to evaluate whether the synthesis of different 68Ga-radiopharmaceuticals or the use of different synthesis methods could affect the amounts of HEPES. RESULTS: HEPES could not be detected by the TLC method described in the Ph Eur within 4 min incubation in an iodine-saturated chamber. As for our modified TLC method, only after 2 h, spots were only visible > 1 mg/mL. The HPLC method had a limit-of-quantification (LOQ) of 3 µg/mL and a limit-of-detection (LOD) of 1 µg/mL. From the three 68Ga-radiopharmaceuticals tested, only in the [68Ga]Ga-NODAGA-Exendin samples exceeding amounts of HEPES were found and its concentration in the [68Ga]Ga-NODAGA-Exendin was significantly higher, when compared to [68Ga]Ga-DOTATOC and [68Ga]Ga-PSMA-11. CONCLUSION: The TLC method described in Ph Eur and our modified TLC method may not be sufficiently sensitive and thus unsuitable to use for QC release. The new HPLC method was sensitive, quantitative, reproducible and suitable for QC release. With this method, we were able to determine that some 68Ga-radiopharmaceuticals may exceed the HEPES limit of 200 µg/ V Injected. This new analytical system would allow correcting for the maximum injected dose in order not to exceed this amount.

5.
EJNMMI Radiopharm Chem ; 5(1): 9, 2020 Apr 10.
Article in English | MEDLINE | ID: mdl-32277373

ABSTRACT

INTRODUCTION: The radiochemical purity (RCP) of technetium-99m labelled radiopharmaceuticals (RP) is important to ensure optimal scintigraphic image quality. In low-income settings, it may not be possible to use compendial analytical methods or expensive equipment for radiochemical purity analysis. All radiochemical analysis methods should however be validated against compendial or otherwise proven methods. To ensure the efficacy of RP prepared at Yaoundé General Hospital (YGH) Cameroon, this study cross-validated a cost-effective routine chromatographic method using a simple survey meter technique. A GMP-compliant method used at the University Medical Center Groningen (UMCG), the Netherlands was used as the comparator. METHODS: Sestamibi, HMDP and DMSA kits currently used at YGH were reconstituted at UMCG with about 2000 MBq of freshly eluted sodium pertechnetate as described by the manufacturer, and spiked with eluate of the same generator to obtain a range of impurity concentrations. Samples of technetium-99m RP were spotted on 1 × 10 cm iTLC-SG strips and developed in appropriate mobile phases. Each strip was first scanned on the chromatogram-scanner used at the UMCG (standard method), and immediately thereafter the strip was cut in two pieces and radioactivity from each portion was counted with a small survey meter from YGH. The percentage RCP for each TLC strip was calculated using both counting methods. Internationally recommended validation parameters and acceptance criteria were used. Student's paired t-test or ANOVA were used with 'no significant difference' designated at a 95% confidence-interval (P ≥ 0.05). Linearity of the survey meter was determined for Tc-99m. Readings obtained with the survey meter were also plotted against the scanner results. RESULTS AND DISCUSSION: The proposed method proved to be accurate (CV of mean RCP < 2), precise (RSD < 2%), linear (slope close to 1, r2 ≥ 0.99) within the RCP range of approximately 80% to 100%, and robust (P > 0.05). LOD and LOQ were determined for the survey meter. Specificity depends on chemical separation. As we were validating the suitability of a method to quantify radioactivity, specificity was not included in the validation parameters. CONCLUSION: The proposed method compared well with the standard method and is suitable as a reliable low cost method for limited resource settings.

6.
J Nucl Cardiol ; 26(4): 1064-1075, 2019 08.
Article in English | MEDLINE | ID: mdl-29943142

ABSTRACT

BACKGROUND: 18F-NaF positron emission tomography (PET) targets microcalcifications. We compared in vitro microPET assessed 18F-NaF uptake between culprit and non-culprit human carotid plaques. Furthermore, we compared 18F-NaF uptake with calcification visualized on microcomputed tomography (microCT). METHODS: Carotid plaques from stroke patients undergoing surgery were incubated in 18F-NaF and scanned using a microPET and a microCT scan. The average PET assessed 18F-NaF uptake was expressed as percentage of the incubation dose per gram (%Inc/g). 18F-NaF PET volume of interest (VOI) was compared with CT calcification VOI. RESULTS: 23 carotid plaques (17 culprit, 6 non-culprit) were included. The average 18F-NaF uptake in culprit carotid plaques was comparable with the uptake in non-culprit carotid plaques (median 2.32 %Inc/g [IQR 1.98 to 2.81] vs. median 2.35 %Inc/g [IQR 1.77 to 3.00], P = 0.916). Only a median of 10% (IQR 4 to 25) of CT calcification VOI showed increased 18F-NaF uptake, while merely a median of 35% (IQR 6 to 42) of 18F-NaF PET VOI showed calcification on CT. CONCLUSIONS: 18F-NaF PET represents a different stage in the calcification process than CT. We observed a similar PET assessed 18F-NaF uptake and pattern in culprit and non-culprit plaques of high-risk patients, indicating that this method may be of more value in early atherosclerotic stenosis development.


Subject(s)
Calcinosis/diagnostic imaging , Carotid Arteries/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Aged , Female , Fluorine Radioisotopes , Humans , Kidney/diagnostic imaging , Male , Middle Aged , Positron-Emission Tomography , Radiopharmaceuticals , Risk Assessment , Sodium Fluoride , Tomography, X-Ray Computed , X-Ray Microtomography
7.
J Nucl Cardiol ; 26(6): 1844-1852, 2019 Dec.
Article in English | MEDLINE | ID: mdl-30288680

ABSTRACT

BACKGROUND: Patients with chest pain and no obstructive coronary artery disease have shown a high incidence of major adverse cardiovascular events (MACE). We evaluated the role of absolute myocardial perfusion quantification in predicting all-cause mortality and MACE during long-term follow-up in this group of patients. METHODS: We studied 79 patients who underwent Nitrogen-13 ammonia PET for quantification of global myocardial blood flow (MBF) and myocardial flow reserve (MFR) due to suspected impaired myocardial perfusion. Patients with coronary artery disease (i.e., > 30% stenosis in one or more coronary arteries) were excluded. We assessed all-cause mortality and MACE. MACE was defined as the composite incidence of death, myocardial infarction (MI), or hospitalization due to heart failure. RESULTS: Median follow-up was 8 (IQR: 3-14) years. Univariate Cox regression showed that only MFR (P = 0.01) was a predictor of all-cause mortality. Univariate Cox regression analysis showed that both MFR and Stress MBF were predictors of the composite endpoint of MACE (P < 0.001 and P = 0.01, respectively). CONCLUSION: Quantitative assessment of myocardial perfusion may predict all-cause mortality and MACE in patients with chest pain and normal coronary arteries in the long-term follow-up.


Subject(s)
Chest Pain/diagnostic imaging , Coronary Vessels/diagnostic imaging , Heart/diagnostic imaging , Myocardium/pathology , Adult , Ammonia , Chest Pain/therapy , Female , Follow-Up Studies , Heart Failure/diagnostic imaging , Heart Failure/mortality , Heart Failure/therapy , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Perfusion Imaging , Nitrogen Radioisotopes , Positron-Emission Tomography , Prognosis , Proportional Hazards Models , Retrospective Studies
8.
EJNMMI Radiopharm Chem ; 1(1): 7, 2017.
Article in English | MEDLINE | ID: mdl-29564384

ABSTRACT

BACKGROUND: 6-[18F]Fluoro-L-3,4-dihydroxyphenylalanine (FDOPA) is a frequently used radiopharmaceutical for detecting neuroendocrine and brain tumors and for the differential diagnosis of Parkinson's disease. To meet the demand for FDOPA, a high-yield GMP-compliant production method is required. Therefore, this study aimed to improve the FDOPA production and quality control procedures to enable distribution of the radiopharmaceutical over distances.FDOPA was prepared by electrophilic fluorination of the trimethylstannyl precursor with [18F]F2, produced from [18O]2 via the double-shoot approach, leading to FDOPA with higher specific activity as compared to FDOPA which was synthesized, using [18F]F2 produced from 20Ne, leading to FDOPA with a lower specific activity. The quality control of the product was performed using a validated UPLC system and compared with quality control with a conventional HPLC system. Impurities were identified using UPLC-MS. RESULTS: The [18O]2 double-shoot radionuclide production method yielded significantly more [18F]F2 with less carrier F2 than the conventional method starting from 20Ne. After adjustment of radiolabeling parameters substantially higher amounts of FDOPA with higher specific activity could be obtained. Quality control by UPLC was much faster and detected more side-products than HPLC. UPLC-MS showed that the most important side-product was FDOPA-quinone, rather than 6-hydroxydopa as suggested by the European Pharmacopoeia. CONCLUSION: The production and quality control of FDOPA were significantly improved by introducing the [18O]2 double-shoot radionuclide production method, and product analysis by UPLC, respectively. As a result, FDOPA is now routinely available for clinical practice and for distribution over distances.

9.
Eur J Vasc Endovasc Surg ; 46(5): 542-8, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24091093

ABSTRACT

OBJECTIVES: Abdominal aortic aneurysm (AAA) is a major cause of death in developed countries. The AAA diameter is still the only validated prognostic measure for rupture, and therapeutic interventions are initiated accordingly. This still leads to unnecessary interventions in some cases or unidentified impending ruptures. Vascular calcification has been validated abundantly as a risk factor in the cardiovascular field and may strengthen the rupture risk assessment of the AAA. With this study we aim to assess the correlation between AAA calcification and rupture risk in a retrospective unmatched case-control population. METHODS: A database of 334 AAA patients was evaluated. Three groups were formed: elective (eAAA; n = 233), ruptured (rAAA; n = 73) and symptomatic non-ruptured (sAAA; n = 28) AAA patients. The Abdominal Aortic Calcification-8 score (AAC-8) was used to measure the severity of vascular calcification. RESULTS: The AAA diameter (61 ± 12 mm vs. 74 ± 21 mm; p < .001) and AAC-8 score (3.4 ± 2 points vs. 4.9 ± 2.3 points; p < .001) of the eAAA and the combined rAAA and sAAA groups, respectively, were significantly different after univariate analysis. Multivariate analysis showed that larger AAA diameter (odds ratio [OR]: 1.048/mm increase; 95% confidence interval [CI]: 1.042-1.082; p < .001) and a higher AAC-8 score (OR: 1.34/point increase; 95% CI: 1.19-1.53; p < .001) were significantly associated with development into a sAAA or rAAA. Peripheral artery disease was significantly correlated to eventual elective treatment (OR: 0.39; 95% CI: .15-1; p = .049). CONCLUSION: This study suggests a trend of an increased degree of calcification in symptomatic or even ruptured AAA patients compared with elective AAA patients.


Subject(s)
Aortic Aneurysm, Abdominal/complications , Aortic Rupture/etiology , Vascular Calcification/complications , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Rupture/diagnostic imaging , Aortic Rupture/surgery , Aortography/methods , Elective Surgical Procedures , Emergencies , Female , Humans , Logistic Models , Male , Middle Aged , Multivariate Analysis , Odds Ratio , Predictive Value of Tests , Prognosis , Retrospective Studies , Risk Factors , Severity of Illness Index , Tomography, X-Ray Computed , Vascular Calcification/diagnostic imaging , Vascular Calcification/surgery , Vascular Surgical Procedures
10.
J Nucl Cardiol ; 18(2): 238-46, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21347555

ABSTRACT

INTRODUCTION: [13N]ammonia PET allows quantification of myocardial perfusion. The similarity between peripheral flow and myocardial perfusion is unclear. We compared perfusion flow in the myocardium with the upper limb during rest and adenosine stress [13N]ammonia PET to establish whether peripheral perfusion reserve (PPR) correlates with MPR. METHODS: [13N]ammonia myocardial perfusion PET-scans of 58 patients were evaluated (27 men, 31 women, age 64 ± 13 years) and were divided in four subgroups: patients with coronary artery disease (CAD, n = 15), cardiac syndrome X (SX, n = 14), idiopathic dilating cardiomyopathy (DCM, n = 16), and normal controls (NC, n = 13). Peripheral limb perfusion was measured in the muscular tissue of the proximal upper limb and quantified through a 2-tissue-compartment model and the PPR was calculated (stress/rest ratio). MPR was also calculated by a 2-tissue-compartment model. The PPR results were compared with the MPR findings. RESULTS: Mean myocardial perfusion increased significantly in all groups as evidenced by the MPR (CAD 1.99 ± 0.47; SX 1.39 ± 0.31; DCM 1.72 ± 0.69; NC 2.91 ± 0.78). Mean peripheral perfusion also increased but not significantly and accompanied with great variations within and between groups (mean PPR: CAD 1.30 ± 0.79; SX 1.36 ± 0.71; DCM 1.60 ± 1.22; NC 1.27 ± 0.63). The mean difference between PPR and MPR for all subpopulations varied widely. No significant correlations in flow reserve were found between peripheral and myocardial microcirculatory beds in any of the groups (Total group: r = -0.07, SEE = 0.70, CAD: r = 0.14, SEE = 0.48, SX: r = 0.17, SEE = 0.30, DCM: r = -0.11, SEE = 0.71, NC: r = -0.19, SEE = 0.80). CONCLUSION: No correlations between myocardial and peripheral perfusion (reserve) were found in different patient populations in the same PET session. This suggests a functional difference between peripheral and myocardial flow in the response to intravenously administered adenosine stress.


Subject(s)
Ammonia , Coronary Circulation , Forearm/blood supply , Myocardial Perfusion Imaging/methods , Positron-Emission Tomography/methods , Adenosine/pharmacology , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Regional Blood Flow , Vasodilation/drug effects
12.
Br J Radiol ; 76(908): 553-60, 2003 Aug.
Article in English | MEDLINE | ID: mdl-12893698

ABSTRACT

Annexin A5 (AnxA5) is a protein with high affinity for phosphatidyl serine, a phospholipid exposed on the cell surface during apoptosis. This phenomenon has been used for determination of cell death after myocardial infarction. To evaluate the potential of (99m)Tc-AnxA5 for in vivo scintigraphy of apoptotic cells, the pharmacokinetics and imaging properties of two radiopharmaceuticals, (99m)Tc-(n-1-imino-4-mercaptobutyl)-AnxA5 (I-AnxA5) and (99m)Tc-(4,5-bis(thioacetamido)pentanoyl)-AnxA5 (B-AnxA5), were studied. I-AnxA5 was administered intravenously to seven patients and one healthy volunteer, and B-AnxA5 was administered to 12 patients. All patients in the pharmacokinetic study had myocardial disease. Additionally, imaging was performed in a patient with acute myocardial infarction, as well as in three patients with different malignancies. The plasma concentration, excretion and biodistribution of (99m)Tc-AnxA5 were measured, as well as levels of AnxA5 antigen. The kinetic data of both radiopharmaceuticals in plasma fitted a two-compartment model. Both preparations had similar half-lives, but a different distribution over the two compartments. Plasma levels of AnxA5 antigen showed a broad variation. Both radiopharmaceuticals accumulated in the kidney, liver and gut. B-AnxA5 was excreted significantly faster than I-AnxA5. Both compounds can be used for imaging of the head/neck region, the thorax and the extremities. B-AnxA5 has a faster clearance and a lower radiation dose. Imaging of apoptosis in the abdomen will be difficult with both radiopharmaceuticals, and especially with B-AnxA5 because of its faster appearance in the gut.


Subject(s)
Annexin A5/pharmacokinetics , Cardiomyopathies/diagnostic imaging , Organotechnetium Compounds/pharmacokinetics , Radiopharmaceuticals/pharmacokinetics , Adult , Aged , Aged, 80 and over , Annexin A5/blood , Apoptosis , Biological Availability , Breast Neoplasms/diagnostic imaging , Half-Life , Humans , Lymphoma, Non-Hodgkin/diagnostic imaging , Middle Aged , Myocardial Infarction/diagnostic imaging , Organotechnetium Compounds/blood , Radiopharmaceuticals/blood , Sarcoma/diagnostic imaging , Tomography, Emission-Computed, Single-Photon/methods
13.
Neth Heart J ; 10(7-8): 313-317, 2002 Aug.
Article in English | MEDLINE | ID: mdl-25696120

ABSTRACT

BACKGROUND: Primary endocardial tumours are rare, but may impose a difficult clinical problem. The definite diagnosis regarding the nature of the tumour is often made after surgery. This is due to the fact that current non-invasive imaging techniques are unable to inform us about the nature of the tumour. In addition, invasive techniques can not be used to obtain biological information of the tumour in these cases, because they carry a high risk of embolic complications. OBJECTIVE: To assess the possibility of a novel modality of imaging, molecular imaging, in the diagnosis of primary intracardiac tumours. METHODS: We evaluated two patients with a primary cardiac tumour. Prior to therapy, we infused human recombinant annexin-V Tc99-m and thallium 201. We used a dual isotope single photon emission computed tomography technique. This allowed us to obtain information about the relation between the anatomical position of the left ventricle and the uptake of the labelled annexin-V within the thoracic cavity. RESULTS: The patient with a malignant primary cardiac tumour showed uptake of labelled annexin-V within the area of the tumour. After surgery, the malignant nature was confirmed by histological analysis. The patient with a benignant intracardiac tumour showed no uptake of annexin-V within the area of the tumour. CONCLUSION: This novel imaging technique, molecular imaging, may be of help to differentiate non-invasively between a malignant and benignant primary intracardiac tumour.

14.
Eur J Nucl Med ; 28(9): 1373-8, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11585297

ABSTRACT

The purpose of this study was to determine the biodistribution and the associated radiation dose of technetium-99m 4,5-bis(thioacetamido)pentanoyl-annexin-V (99mTc-Apomate), a tracer proposed for the study of apoptosis. Eight patients (including two females) with normal kidney and liver functions were included in the study. An activity of 580 +/- 90 MBq of 99mTc-Apomate was injected intravenously, immediately followed by a dynamic study of 30 frames of 1 min each. At about 1 h, 4 h and 20 h p.i., whole-body scans were acquired. All activity distributions were measured using a dual-head gamma camera. Before injection of activity, a transmission scan with a cobalt-57 flood source had been performed to determine patient attenuation. Blood samples were taken every 10 min during the first hour after injection, and at about 4 and 20 h. Urine and faeces were collected during the first 20 h. Organ uptake was estimated after correction for body background activity, attenuation and scatter. Residence times were calculated from the dynamic and whole-body studies and used as input in the Mirdose 3.1 program to obtain organ doses and effective dose. It was found that radioactivity strongly accumulated in the kidneys and the liver [at 70 min p.i., 28% +/- 8% and 20% +/- 4% of the injected dose (ID), respectively]. Uptake in the target tissues (lymphomas or heart) was negligible from a dosimetric point of view. Extrapolating data from the first 20 h, one finds that approximately 73% of the ID will be excreted in the urine, and 27% in the faeces. The biological half-life of the activity in the total body was 16 +/- 7 h. Some organ doses +/- standard deviation (SD) in microGy/MBq were: kidneys 63 +/- 22, urinary bladder 20 +/- 6, spleen 15 +/- 3, liver 13 +/- 3, upper large intestine 12 +/- 6, lower large intestine 8 +/- 4, testes 6 +/- 2 and red bone marrow 4 +/- 0.7. The effective dose was 7.6 +/- 0.5 microSv/MBq, corresponding to a total effective dose of 4.6 +/- 0.3 mSv for a nominal injected activity of 600 MBq. In conclusion, 99mTc-Apomate has a high uptake in the kidneys and liver--in fact a factor of 1.3-1.6 higher than that found for the previously studied 99mTc-(n-1-imino-4-mercaptobutyl)-annexin-V. The biological half-life is shorter, however, but still long compared with the physical half-life of 99mTc. The faster appearance of activity in the intestines may preclude imaging of apoptosis in the abdomen. The effective dose is within the lower range of values reported for typical 99mTc compounds.


Subject(s)
Annexin A5 , Apoptosis , Organotechnetium Compounds , Radiopharmaceuticals/pharmacokinetics , Adult , Aged , Aged, 80 and over , Annexin A5/pharmacokinetics , Feces/chemistry , Female , Gamma Cameras , Half-Life , Heart/diagnostic imaging , Humans , Kidney/diagnostic imaging , Kidney/metabolism , Liver/diagnostic imaging , Liver/metabolism , Lymphoma/diagnostic imaging , Lymphoma/metabolism , Male , Middle Aged , Myocardium/metabolism , Organotechnetium Compounds/pharmacokinetics , Radiation Dosage , Radionuclide Imaging , Time Factors , Tissue Distribution , Urine/chemistry
16.
J Nucl Med ; 42(2): 382-7, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11216539

ABSTRACT

UNLABELLED: Annexin V labeled with 99mTc is evaluated as a potential in vivo marker for tissue with increased apoptosis. Promising results in patients have been obtained with 99mTc-(n-1-imino-4-mercaptobutyl)-annexin V (99mTc-i-AnxV). Because information on biodistribution and radiation burden is desired for the application of any radiopharmaceutical, a dosimetric study of 99mTc-i-AnxV was undertaken. METHODS: Eight persons with normal kidney and liver functions were included in this study: six patients with myocardial infarction, one with Crohn's disease, and one healthy volunteer. Approximately 600 MBq 99mTc-i-AnxV were injected intravenously immediately before a dynamic study with a dual-head gamma camera in conjugate view mode. In the next 24 h, two to four whole-body scans were acquired. Patient thickness was determined from a transmission scan with a 57Co flood source. Organ uptake was estimated after correction for background, attenuation, and scatter, using a depth-independent buildup factor and an organ-size-dependent attenuation correction. Residence times were calculated from the dynamic and whole-body studies and used as input for the MIRDOSE 3.1 program to obtain organ-absorbed doses and effective dose. RESULTS: Activity strongly accumulated in the kidneys (21% +/- 6% of the injected dose at 4 h postinjection) and the liver (12.8% +/- 2.2%). Uptake in the target tissues (myocardium or colon) was limited and negligible from a dosimetric point of view. The biologic half-life of activity registered over the total body was 62 +/- 13 h. Of the excreted activity, approximately 75% went to the urine and 25% to the feces. The absorbed dose for the more strongly exposed organs was (in microGy/MBq): kidneys, 93 +/- 24; spleen, 22 +/- 6; liver, 17 +/- 2; testes, 15 +/- 3; thyroid, 10 +/- 6; urinary bladder wall, 7.5 +/- 2.6; and red bone marrow, 5.5 +/- 0.8. The effective dose was 9.7 +/- 1.0 microSv/MBq, corresponding to a total effective dose of 5.8 +/- 0.6 mSv for a nominally injected activity of 600 MBq. CONCLUSION: 99mTc-i-AnxV strongly accumulates in the kidneys and to a lesser degree in the liver. The associated effective dose per MBq is in the midrange of values found for routine 99mTc-labeled compounds. From a dosimetric point of view 99mTc-i-AnxV is therefore well suited for the study of apoptosis in patients.


Subject(s)
Annexin A5/pharmacokinetics , Organotechnetium Compounds/pharmacokinetics , Radiopharmaceuticals/pharmacokinetics , Adult , Aged , Annexin A5/administration & dosage , Apoptosis , Female , Humans , Injections, Intravenous , Male , Middle Aged , Organotechnetium Compounds/administration & dosage , Radiation Dosage , Radiopharmaceuticals/administration & dosage , Tissue Distribution
17.
Lancet ; 356(9225): 209-12, 2000 Jul 15.
Article in English | MEDLINE | ID: mdl-10963199

ABSTRACT

BACKGROUND: In-vivo visualisation and quantification of the extent and time-frame of cell death after acute myocardial infarction would be of great interest. We studied in-vivo cell death in the hearts of patients with an acute myocardial infarction using imaging with technetium-99m-labelled annexin-V-a protein that binds to cells undergoing apoptosis. METHODS: Seven patients with an acute myocardial infarction and one control were studied. All patients were treated by percutaneous transluminal coronary angioplasty (six primary and one rescue), resulting in thrombolysis in myocardial infarction (TIMI) III flow of the infarct-related artery. 2 h after reperfusion, 1 mg annexin-V labelled with 584 MBq Tc-99m was injected intravenously. Early (mean 3.4 h) and late (mean 20.5 h) single-photon-emission computed tomographic (SPECT) images of the heart were obtained. Routine myocardial resting-perfusion imaging was also done to verify infarct localisation. FINDINGS: In six of the seven patients, increased uptake of Tc-99m-labelled annexin-V was seen in the infarct area of the heart on early and late SPECT images. No increased uptake was seen in the heart outside the infarct area. All patients with increased Tc-99m-labelled annexin-V uptake in the infarct area showed a matching perfusion defect. In a control individual, no increased uptake in the heart was seen. INTERPRETATION: Increased uptake of Tc-99m-labelled annexin-V is present in the infarct area of patients with an acute myocardial infarction, suggesting that programmed cell death occurs in that area. The annexin-V imaging protocol might allow us to study the dynamics of reperfusion-induced cell death in the area at risk and may help to assess interventions that inhibit cell death in patients with an acute myocardial infarction.


Subject(s)
Annexin A5 , Myocardial Infarction/diagnostic imaging , Myocardium/pathology , Radiopharmaceuticals , Sodium Pertechnetate Tc 99m , Aged , Angioplasty, Balloon, Coronary , Apoptosis , Cell Death , Coronary Circulation/physiology , Coronary Vessels/diagnostic imaging , Female , Follow-Up Studies , Heart/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Injections, Intravenous , Male , Middle Aged , Myocardial Infarction/therapy , Organophosphorus Compounds , Organotechnetium Compounds , Protein Binding , Radiopharmaceuticals/administration & dosage , Reperfusion Injury/diagnostic imaging , Sodium Pertechnetate Tc 99m/administration & dosage , Technetium Tc 99m Sestamibi , Tomography, Emission-Computed, Single-Photon
19.
Phytomedicine ; 1(3): 239-44, 1994 Dec.
Article in English | MEDLINE | ID: mdl-23195945

ABSTRACT

Therapy with 5-fluorouracil (5-FU) as a single agent has only limited success in palliative treatment of cancer of the large bowel. In the current study, the effect of quercetin on the action of 5-FU in the human colorectal cancer cell lines COLO 320 DM and COLO 205 was evaluated using the MTT and clonogenic assays. Both assays were used in order to discriminate between cell growth inhibition and actual cell kill. As single agents as well as in combination, considerably higher concentrations of 5-FU and quercetin were required in the clonogenic assay to obtain detectable effects than in the MTT assay. In the MTT assay, but not in the clonogenic assay, a synergistic interaction between quercetin and 5-FU was found for COLO 320 DM cells. Our results therefore indicate that this interaction between quercetin and 5-FU mainly takes place at the level of growth inhibition. It is concluded that the cytostatic action of a combination of quercetin and 5-FU in COLO 320 DM cells is superior to that of the single agents.

SELECTION OF CITATIONS
SEARCH DETAIL
...