Results 1 - 11 de 11
Filter
1.
Phys Imaging Radiat Oncol ; 29: 100543, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38390588

ABSTRACT

Background and purpose: Multi-leaf collimators (MLCs) with tilted leaf sides have a complex transmission behaviour that is not easily matched by radiotherapy treatment planning systems (TPSs). We sought to develop an MLC model that can accurately match test fields and clinically relevant plans at different centres. Materials and methods: Two new MLC models were developed and evaluated within a research version of a commercial TPS. Prototype I used adjusted-constant transmissions and Prototype II used variable transmissions at the tongue-and-groove and leaf-tip regions. Three different centres evaluated these prototypes for a tilted MLC and compared them with their initial MLC model using test fields and patient-specific quality-assurance measurements of clinically relevant plans. For the latter, gamma passing rates (GPR) at 2 %/2mm were recorded. Results: For the prototypes the same set of MLC parameters could be used at all centres, with only a slight adjustment of the offset parameter. For centres A and C, average GPR were >95 % and within 0.5 % GPR difference between the standard, and prototype models. In center B, prototypes I and II improved the agreement in clinically relevant plans, with an increase in GPR of 2.3 % ± 0.8 % and 3.0 ± 0.8 %, respectively. Conclusions: The prototype MLC models were either similar or superior to the initial MLC model, and simpler to configure because fewer trade-offs were required. Prototype I performed comparably to the more sophisticated Prototype II and its configuration can be easily standardized, which can be useful to reduce variability and improve safety in clinical practice.

2.
Phys Imaging Radiat Oncol ; 29: 100523, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38187170

ABSTRACT

Background and purpose: This work reports on the results of a survey performed on the use of computed tomography (CT) imaging for motion management, surface guidance devices, and their quality assurance (QA). Additionally, it details the collected user insights regarding professional needs in CT for radiotherapy. The purpose of the survey is to understand current practice, professional needs and future directions in the field of fan-beam CT in radiation therapy (RT). Materials and methods: An online institutional survey was conducted between 1-Sep-2022 and 10-Oct-2022 among medical physics experts at Belgian and Dutch radiotherapy institutions, to assess the current status, challenges, and future directions of motion management and surface image-guided radiotherapy. The survey consisted of a maximum of 143 questions, with the exact number depending on participants' responses. Results: The response rate was 66 % (31/47). Respiratory management was reported as standard practice in all but one institution; surface imaging during CT-simulation was reported in ten institutions. QA procedures are applied with varying frequencies and methodologies, primarily with commercial anatomy-like phantoms. Surface guidance users report employing commercial static and dynamic phantoms. Four main subjects are considered clinically important by the respondents: surface guidance, CT protocol optimisation, implementing gated imaging (4DCT, breath-hold), and a tattoo-less workflow. Conclusions: The survey highlights the scattered pattern of QA procedures for respiratory motion management, indicating the need for well-defined, unambiguous, and practicable guidelines. Surface guidance is considered one of the most important techniques that should be implemented in the clinical radiotherapy simulation workflow.

3.
Phys Imaging Radiat Oncol ; 29: 100522, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38152701

ABSTRACT

Background and purpose: To obtain an understanding of current practice, professional needs and future directions in the field of fan-beam CT in RT, a survey was conducted. This work presents the collected information regarding the use of CT imaging for dose calculation and structure delineation. Materials and methods: An online institutional survey was distributed to medical physics experts employed at Belgian and Dutch radiotherapy institutions to assess the status, challenges, and future directions of QA practices for fan-beam CT. A maximum of 143 questions covered topics such as CT scanner availability, CT scanner specifications, QA protocols, treatment simulation workflow, and radiotherapy dose calculation. Answer forms were collected between 1-Sep-2022 and 10-Oct-2022. Results: A 66 % response rate was achieved, yielding data on a total of 58 CT scanners. For MV photon therapy, all single-energy CT scans are reconstructed in Hounsfield Units for delineation or dose calculation, and a direct- or stoichiometric method was used to convert CT numbers for dose calculation. Limited use of dual-energy CT is reported for photon (N = 3) and proton dose calculations (N = 1). For brachytherapy, most institutions adopt water-based dose calculation, while approximately 26 % of the institutions take tissue heterogeneity into account. Commissioning and regular QA include eleven tasks, which are performed by two or more professions (29/31) with varying frequencies. Conclusions: Dual usage of a planning CT limits protocol optimization for both tissue characterization and delineation. DECT has been implemented only gradually. A variation of QA testing frequencies and tests are reported.

4.
Phys Imaging Radiat Oncol ; 28: 100479, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37694265

ABSTRACT

Background and purpose: 4D Computed Tomography (4DCT) technology captures the location and movement of tumors and nearby organs at risk over time. In this study, a multi-institutional multi-vendor 4DCT audit was initiated to assess the accuracy of current imaging protocols. Materials and methods: Twelve centers, including thirteen scanners performed a 4DCT acquisition of a dynamic thorax phantom using the institution's own protocol with the in-house breathing monitoring system. Five regular and three irregular breathing patterns were used. Image acquisition and reconstruction were followed by automated image analysis with our in-house developed 4DCT QA program (QAMotion). CT number accuracy, volume deviation, amplitude deviation, and spatial integrity were assessed per pattern using both the segmented volumes and line profiles. Results: Regular breathing curves showed relatively accurate results across all institutions, with mean volume and CT number deviations and median amplitude deviation below 2%, 5 HU and 2 mm, respectively. Results obtained for irregular patterns showed more variation across the institutions. Volume and CT number deviations co-occurred with a blurring of the sphere, interpolation, or double-structure artifacts that were confirmed through the line profiles. For some of the irregular patterns, amplitude deviations up to 6 mm were observed. Maximum Intensity Projection (MaxIP) correctly captured the applied motion amplitude with deviations across all institutions within 2 mm except for double amplitude pattern. Conclusions: All centers invited to participate in the audit responded positively, highlighting the need for a comprehensive yet easy-to-execute 4DCT quality assurance program. The largest variances between the results from one institution to another confirmed that a standardized 4DCT audit is warranted.

5.
Phys Imaging Radiat Oncol ; 27: 100475, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37560513

ABSTRACT

This study aimed to develop and validate a comprehensive, reproducible and automatic 4DCT Quality Assurance (QA) workflow (QAMotion) that evaluates image accuracy across various regular and irregular breathing patterns. Volume and amplitude deviations, CT number accuracy, and spatial integrity were used as evaluation metrics. For repeatability tests, tolerances were respected with a mean CT number deviation < 10 HU, volume deviation < 2% and diameter and amplitude deviation < 2 mm except for irregular amplitude curves for which an amplitude deviation up to 6 mm was measured. QAMotion was able to flag image artefacts for our clinical 4DCT system.

6.
Radiother Oncol ; 186: 109775, 2023 09.
Article in English | MEDLINE | ID: mdl-37385376

ABSTRACT

PURPOSE: To demonstrate the feasibility of characterising MLCs and MLC models implemented in TPSs using a common set of dynamic beams. MATERIALS AND METHODS: A set of tests containing synchronous (SG) and asynchronous sweeping gaps (aSG) was distributed among twenty-five participating centres. Doses were measured with a Farmer-type ion chamber and computed in TPSs, which provided a dosimetric characterisation of the leaf tip, tongue-and-groove, and MLC transmission of each MLC, as well as an assessment of the MLC model in each TPS. Five MLC types and four TPSs were evaluated, covering the most frequent combinations used in radiotherapy departments. RESULTS: Measured differences within each MLC type were minimal, while large differences were found between MLC models implemented in clinical TPSs. This resulted in some concerning discrepancies, especially for the HD120 and Agility MLCs, for which differences between measured and calculated doses for some MLC-TPS combinations exceeded 10%. These large differences were particularly evident for small gap sizes (5 and 10 mm), as well as for larger gaps in the presence of tongue-and-groove effects. A much better agreement was found for the Millennium120 and Halcyon MLCs, differences being within ± 5% and ± 2.5%, respectively. CONCLUSIONS: The feasibility of using a common set of tests to assess MLC models in TPSs was demonstrated. Measurements within MLC types were very similar, but TPS dose calculations showed large variations. Standardisation of the MLC configuration in TPSs is necessary. The proposed procedure can be readily applied in radiotherapy departments and can be a valuable tool in IMRT and credentialing audits.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Phantoms, Imaging , Radiometry/methods , Radiotherapy, Intensity-Modulated/methods
7.
Med Phys ; 49(7): 4755-4767, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35543491

ABSTRACT

PURPOSE: This work presents the clinical validation of RayStation's electron Monte Carlo code by the use of diodes and plane parallel radiation detectors in homogenous and heterogeneous tissues. Results are evaluated against internationally accepted criteria. METHODS: The Monte Carlo-based electron beam dose calculation code was validated using diodes, air- and liquid-filled parallel radiation detectors on an Elekta linac with beam energies of 4, 6, 8, 10, and 12 MeV. Treatment setups with varying source-to-skin distances, different applicators, various cutouts, and oblique beam incidences were addressed, together with dose prediction behind lung-, air-, and bone-equivalent inserts. According to NCS (Netherlands Commission for Radiation Dosimetry) report 15 for nonstandard treatment setups, a dose agreement of 3% in the δ1 region (high-dose region around Zref ), a distance-to-agreement (DTA) of 3 mm or a dose agreement of 10% in the δ2 region (regions with high-dose gradients), and 4% in the δ4 region (photon tail/low-dose region) were applied. During validation, clinical routine settings of 2 × 2 × 2-mm3 dose voxels and a statistically dose uncertainty of 0.6% (250 000 histories/cm2 ) were used. RESULTS: RayStation's electron Monte Carlo code dose prediction was able to achieve the tolerances of NCS report 15. Output predictions as a function of the SSD improve with energy and applicator size. Cutout data revealed no field size or energy dependence on the accuracy of the dose prediction. Excellent agreement for the oblique incidence data was achieved and a maximum of one voxel difference was obtained for the DTA behind heterogeneous inserts. CONCLUSIONS: The accuracy of RayStation's Monte Carlo-based electron beam dose prediction for Elekta accelerators is confirmed for clinical treatment planning that is not only performed within an acceptable timeframe in terms of the number of histories but also addresses for homogenous and heterogeneous media.


Subject(s)
Electrons , Radiotherapy Planning, Computer-Assisted , Algorithms , Monte Carlo Method , Particle Accelerators , Phantoms, Imaging , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods
8.
Radiother Oncol ; 136: 78-85, 2019 07.
Article in English | MEDLINE | ID: mdl-31015133

ABSTRACT

BACKGROUND AND PURPOSE: The prognostic value of radiomics for non-small cell lung cancer (NSCLC) patients has been investigated for images acquired prior to treatment, but no prognostic model has been developed that includes the change of radiomic features during treatment. Therefore, the aim of this study was to investigate the potential added prognostic value of a longitudinal radiomics approach using cone-beam computed tomography (CBCT) for NSCLC patients. MATERIALS AND METHODS: This retrospective study includes a training dataset of 141 stage I-IV NSCLC patients and three external validation datasets of 94, 61 and 41 patients, all treated with curative intended (chemo)radiotherapy. The change of radiomic features extracted from CBCT images was summarized as the slope of a linear regression. The CBCT slope-features and CT-extracted features were used as input for a Cox proportional hazards model. Moreover, prognostic performance of clinical parameters was investigated for overall survival and locoregional recurrence. Model performances were assessed using the Kaplan-Meier curves and c-index. RESULTS: The radiomics model contained only CT-derived features and reached a c-index of 0.63 for overall survival and could be validated on the first validation dataset. No model for locoregional recurrence could be developed that validated on the validation datasets. The clinical parameters model could not be validated for either overall survival or locoregional recurrence. CONCLUSION: In this study we could not confirm our hypothesis that longitudinal CBCT-extracted radiomic features contribute to improved prognostic information. Moreover, performance of baseline radiomic features or clinical parameters was poor, probably affected by heterogeneity within and between datasets.


Subject(s)
Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Cone-Beam Computed Tomography/methods , Lung Neoplasms/diagnostic imaging , Adult , Aged , Aged, 80 and over , Carcinoma, Non-Small-Cell Lung/mortality , Carcinoma, Non-Small-Cell Lung/radiotherapy , Female , Humans , Lung Neoplasms/mortality , Lung Neoplasms/radiotherapy , Male , Middle Aged , Neoplasm Recurrence, Local , Prognosis , Proportional Hazards Models , Retrospective Studies
9.
Radiother Oncol ; 107(3): 377-81, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23791364

ABSTRACT

PURPOSE: To investigate whether rotational techniques (Volumetric Modulated Arc Therapy - VMAT) are associated with a higher risk for secondary primary malignancies compared to step-and-shoot Intensity Modulated Radiation Therapy (ss-IMRT). To this end, radiation therapy (RT) induced DNA double-strand-breaks and the resulting chromosomal damage were assessed in peripheral blood T-lymphocytes of prostate cancer (PCa) patients applying γH2AX foci and G0 micronucleus (MN) assays. METHODS AND MATERIALS: The study comprised 33PCa patients. A blood sample was taken before start of therapy and after the 1st and 3rd RT fraction to determine respectively the RT-induced γH2AX foci and MN. The equivalent total body dose (D(ETB)) was calculated based on treatment planning data. RESULTS: A linear dose response was obtained for γH2AX foci yields versus D(ETB) while MN showed a linear-quadratic dose response. Patients treated with large volume (LV) VMAT show a significantly higher level of induced γH2AX foci and MN compared to IMRT and small volume (SV) VMAT (p<0.01). Assuming a linear-quadratic relationship, a satisfactory correlation was found between both endpoints (R(2) 0.86). CONCLUSIONS: Biomarker responses were governed by dose and irradiated volume of normal tissues. No significant differences between IMRT and rotational therapy inherent to the technique itself were observed.


Subject(s)
Biomarkers, Tumor/analysis , Neoplasms, Second Primary/etiology , Prostatic Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/adverse effects , Aged , Dose-Response Relationship, Radiation , Histones/analysis , Humans , Male , Micronuclei, Chromosome-Defective , Middle Aged , Prostatic Neoplasms/genetics , Radiotherapy Dosage , Risk
10.
Radiother Oncol ; 100(2): 227-30, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21377749

ABSTRACT

Volumetric discrepancies between cone-beam computed tomography (CBCT) and planning CT image sets were investigated for both prone and supine breast radiotherapy. A phantom study was performed in order to examine the artefacts' dependency on CBCT acquisition parameters and to minimize their effect on patient set-up accuracy.


Subject(s)
Breast Neoplasms/radiotherapy , Cone-Beam Computed Tomography/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Female , Humans , Phantoms, Imaging , Prone Position , Supine Position
11.
Circulation ; 111(1): 83-9, 2005 Jan 04.
Article in English | MEDLINE | ID: mdl-15611374

ABSTRACT

BACKGROUND: Because of the higher radiosensitivity of infants and children compared with adults, there is a need to evaluate the doses delivered to pediatric patients who undergo interventional cardiac procedures. However, knowledge of the effective dose in pediatric interventional cardiology is very limited. METHODS AND RESULTS: For an accurate risk estimation, a patient-specific Monte Carlo simulation of the effective dose was set up in 60 patients with congenital heart disease who underwent diagnostic (n=28) or therapeutic (n=32) cardiac catheterization procedures. The dose-saving effect of using extra copper filtration in the x-ray beam was also investigated. For diagnostic cardiac catheterizations, a median effective dose of 4.6 mSv was found. Therapeutic procedures resulted in a higher median effective dose of 6.0 mSv because of the prolonged use of fluoroscopy. The overall effect of inserting extra copper filtration into the x-ray beam was a total effective dose reduction of 18% with no detrimental effect on image quality. An excellent correlation between the dose-area product and effective patient dose was found (r=0.95). Hence, dose-area product is suitable for online estimation of the effective dose with good accuracy. With all procedures included, the resulting median lifetime risk for stochastic effects was 0.08%. CONCLUSIONS: Because of the high radiation exposure, it is important to monitor patient dose by dose-area product instrumentation and to use additional beam filtration to keep the effective dose as low as possible in view of the sensitivity of the pediatric patients.


Subject(s)
Cardiac Catheterization , Radiometry , Cardiac Catheterization/adverse effects , Child , Child, Preschool , Computer Simulation , Copper , Dose-Response Relationship, Radiation , Equipment Design , Female , Fluoroscopy/adverse effects , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/surgery , Humans , Infant , Infant, Newborn , Male , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage , Radiation Injuries/epidemiology , Radiation Injuries/etiology , Radiology, Interventional , Risk , Risk Assessment , Skin/radiation effects , Stochastic Processes , Thermoluminescent Dosimetry