Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Curr Opin Organ Transplant ; 27(5): 446-453, 2022 10 01.
Article in English | MEDLINE | ID: mdl-35857331

ABSTRACT

PURPOSE OF REVIEW: This review aims to summarize the latest original preclinical and clinical articles in the setting of normothermic machine perfusion (NMP) of kidney grafts. RECENT FINDINGS: Kidney NMP can be safely translated into the clinical routine and there is increasing evidence that NMP may be beneficial in graft preservation especially in marginal kidney grafts. Due to the near-physiological state during NMP, this technology may be used as an ex-vivo organ assessment and treatment platform. There are reports on the application of mesenchymal stromal/stem cells, multipotent adult progenitor cells and microRNA during kidney NMP, with first data indicating that these therapies indeed lead to a decrease in inflammatory response and kidney injury. Together with the demonstrated possibility of prolonged ex-vivo perfusion without significant graft damage, NMP could not only be used as a tool to perform preimplant graft assessment. Some evidence exists that it truly has the potential to be a platform to treat and repair injured kidney grafts, thereby significantly reducing the number of declined organs. SUMMARY: Kidney NMP is feasible and can potentially increase the donor pool not only by preimplant graft assessment, but also by ex-vivo graft treatment.


Subject(s)
Kidney Transplantation , Organ Preservation , Adult , Humans , Kidney , Kidney Transplantation/adverse effects , Organ Preservation/adverse effects , Perfusion , Tissue Donors
2.
Transplantation ; 106(4): 792-805, 2022 04 01.
Article in English | MEDLINE | ID: mdl-34144552

ABSTRACT

BACKGROUND: Normothermic machine perfusion (NMP) has become a clinically established tool to preserve livers in a near-physiological environment. However, little is known about the predictive value of perfusate parameters toward the outcomes after transplantation. METHODS: Fifty-five consecutive NMP livers between 2018 and 2019 were included. All of the livers were perfused on the OrganOx metra device according to an institutional protocol. Transplant and perfusion data were collected prospectively. RESULTS: Forty-five livers were transplanted after NMP. Five livers stem from donors after circulatory death and 31 (68.9%) from extended criteria donors. Mean (SD) cold ischemia time was 6.4 (2.3) h; mean (SD) total preservation time was 21.4 (7.1) h. Early allograft dysfunction (EAD) occurred in 13 of 45 (28.9%) patients. Perfusate aspartate aminotransferase (P = 0.008), alanine aminotransferase (P = 0.006), lactate dehydrogenase (P = 0.007) and their development over time, alkaline phosphatase (P = 0.013), and sodium (P = 0.016) correlated with EAD. Number of perfusate platelets correlated with cold ischemia time duration and were indicative for the occurrence of EAD. Moreover, von Willebrand Factor antigen was significantly higher in perfusates of EAD livers (P < 0.001), and Δ von Willebrand factor antigen correlated with EAD. Although perfusate lactate and glucose had no predictive value, EAD was more likely to occur in livers with lower perfusate pH (P = 0.008). ΔPerfusate alkaline phosphatase, Δperfusate aspartate aminotransferase, Δperfusate alanine aminotransferase, and Δperfusate lactate dehydrogenase correlated closely with model for early allograft function but not liver graft assessment following transplantation risk score. Bile parameters correlated with extended criteria donor and donor risk index. CONCLUSIONS: Biomarker assessment during NMP may help to predict EAD after liver transplantation. The increase of transaminases and lactate dehydrogenase over time as well as platelets and vWF antigen are important factors indicative for EAD.


Subject(s)
Allografts/immunology , Blood Platelets , Enzymes , Liver Transplantation , Liver , Organ Preservation , Perfusion , Biomarkers , Humans , Organ Preservation/methods , Perfusion/adverse effects
3.
Int J Mol Sci ; 22(10)2021 May 15.
Article in English | MEDLINE | ID: mdl-34063399

ABSTRACT

Transplantation represents the treatment of choice for many end-stage diseases but is limited by the shortage of healthy donor organs. Ex situ normothermic machine perfusion (NMP) has the potential to extend the donor pool by facilitating the use of marginal quality organs such as those from donors after cardiac death (DCD) and extended criteria donors (ECD). NMP provides a platform for organ quality assessment but also offers the opportunity to treat and eventually regenerate organs during the perfusion process prior to transplantation. Due to their anti-inflammatory, immunomodulatory and regenerative capacity, mesenchymal stem cells (MSCs) are considered as an interesting tool in this model system. Only a limited number of studies have reported on the use of MSCs during ex situ machine perfusion so far with a focus on feasibility and safety aspects. At this point, no clinical benefits have been conclusively demonstrated, and studies with controlled transplantation set-ups are urgently warranted to elucidate favorable effects of MSCs in order to improve organs during ex situ machine perfusion.


Subject(s)
Mesenchymal Stem Cells , Organ Preservation/methods , Organ Transplantation/methods , Perfusion/methods , Animals , Humans , Mesenchymal Stem Cell Transplantation , Regenerative Medicine/methods , Time Factors , Tissue Donors , Tissue and Organ Procurement/methods
4.
Transplant Proc ; 52(9): 2707-2710, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32800515

ABSTRACT

The coronavirus disease 2019 (COVID-19) pandemic has changed life on a global scale. The numbers of transplantations have plummeted as a result of fear of disease transmission, recipient coronavirus disease 2019 infection, priority shift, and resource limitations. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) complicates transplantation because donor testing, (re)allocation of limited resources, and recipient testing may exceed permissible ischemia times. Normothermic machine perfusion (NMP) helps safely prolong liver preservation up to 38 hours. Additional time is essential under the current circumstances. Here we present the case of a 29-year-old liver transplant recipient in whom prolonged liver preservation required for SARS-CoV-2 screening was accomplished through NMP. Donor and recipient test results for SARS-CoV-2 were negative, and intensive care unit capacity was eventually available. The surgical procedure and postoperative course were uneventful. NMP can extend preservation times in liver transplantation while awaiting SARS-CoV-2 test results and available intensive care unit capacity.


Subject(s)
Clinical Laboratory Techniques , Coronavirus Infections/diagnosis , Liver Transplantation/methods , Organ Preservation/methods , Pneumonia, Viral/diagnosis , Adult , Betacoronavirus , COVID-19 , COVID-19 Testing , Female , Humans , Pandemics , Perfusion/methods , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Tissue Donors
5.
J Clin Med ; 9(7)2020 Jul 21.
Article in English | MEDLINE | ID: mdl-32708180

ABSTRACT

Hypothermic machine perfusion (HMP) has been introduced as an alternative to static cold storage (SCS) in kidney transplantation, but its true benefit in the clinical routine remains incompletely understood. The aim of this study was to assess the effect of HMP vs. SCS in kidney transplantation. All kidney transplants performed between 08/2015 and 12/2019 (n = 347) were propensity score (PS) matched for cold ischemia time (CIT), extended criteria donor (ECD), gender mismatch, cytomegalovirus (CMV) mismatch, re-transplantation and Eurotransplant (ET) senior program. A total of 103 HMP and 103 SCS instances fitted the matching criteria. Prior to PS matching, the CIT was longer in the HMP group (17.5 h vs. 13.3 h; p < 0.001), while the delayed graft function (DGF) rates were 29.8% and 32.3% in HMP and SCS, respectively. In the PS matched groups, the DGF rate was 64.1% in SCS vs. 31.1% following HMP: equivalent to a 51.5% reduction of the DGF rate (OR 0.485, 95% CI 0.318-0.740). DGF was associated with decreased 1- and 3-year graft survival (100% and 96.3% vs. 90.8% and 86.7%, p = 0.001 and p = 0.008) or a 4.1-fold increased risk of graft failure (HR = 4.108; 95% CI: 1.336-12.631; p = 0.014). HMP significantly reduces DGF in kidney transplantation. DGF remains a strong predictor of graft survival.

SELECTION OF CITATIONS
SEARCH DETAIL
...