1.
EJNMMI Phys ; 10(1): 8, 2023 Feb 07.
Article in English | MEDLINE | ID: mdl-36749446

ABSTRACT

BACKGROUND: In selective internal radiation therapy, 99mTc SPECT images are used to optimize patient treatment planning, but they are affected by respiratory motion. In this study, we evaluated on patient data the dosimetric impact of motion-compensated SPECT reconstruction on several volumes of interest (VOI), on the tumor-to-normal liver (TN) ratio and on the activity to be injected. METHODS: Twenty-nine patients with liver cancer or hepatic metastases treated by radioembolization were included in this study. The biodistribution of 90Y is assumed to be the same as that of 99mTc when predictive dosimetry is implemented. A total of 31 99mTc SPECT images were acquired and reconstructed with two methods: conventional OSEM (3D) and motion-compensated OSEM (3Dcomp). Seven VOI (liver, lungs, tumors, perfused liver, hepatic reserve, healthy perfused liver and healthy liver) were delineated on the CT or obtained by thresholding SPECT images followed by Boolean operations. Absorbed doses were calculated for each reconstruction using Monte Carlo simulations. Percentages of dose difference (PDD) between 3Dcomp and 3D reconstructions were estimated as well as the relative differences for TN ratio and activities to be injected. The amplitude of movement was determined with local rigid registration of the liver between the 3Dcomp reconstructions of the extreme phases of breathing. RESULTS: The mean amplitude of the liver was 9.5 ± 2.7 mm. Medians of PDD were closed to zero for all VOI except for lungs (6.4%) which means that the motion compensation overestimates the absorbed dose to the lungs compared to the 3D reconstruction. The smallest lesions had higher PDD than the largest ones. Between 3D and 3Dcomp reconstructions, means of differences in lung dose and TN ratio were not statistically significant, but in some cases these differences exceed 1 Gy (4/31) and 8% (2/31). The absolute differences in activity were on average 3.1% ± 5.1% and can reach 22.8%. CONCLUSION: The correction of respiratory motion mainly impacts the lung and tumor doses but only for some patients. The largest dose differences are observed for the smallest lesions.

2.
EJNMMI Phys ; 8(1): 56, 2021 Jul 27.
Article in English | MEDLINE | ID: mdl-34318383

ABSTRACT

BACKGROUND: PET imaging of 90Y-microsphere distribution following radioembolisation is challenging due to the count-starved statistics from the low branching ratio of e+/e- pair production during 90Y decay. PET systems using silicon photo-multipliers have shown better 90Y image quality compared to conventional photo-multiplier tubes. The main goal of the present study was to evaluate reconstruction parameters for different phantom configurations and varying listmode acquisition lengths to improve quantitative accuracy in 90Y dosimetry, using digital photon counting PET/CT. METHODS: Quantitative PET and dosimetry accuracy were evaluated using two uniform cylindrical phantoms specific for PET calibration validation. A third body phantom with a 9:1 hot sphere-to-background ratio was scanned at different activity concentrations of 90Y. Reconstructions were performed using OSEM algorithm with varying parameters. Time-of-flight and point-spread function modellings were included in all reconstructions. Absorbed dose calculations were carried out using voxel S-values convolution and were compared to reference Monte Carlo simulations. Dose-volume histograms and root-mean-square deviations were used to evaluate reconstruction parameter sets. Using listmode data, phantom and patient datasets were rebinned into various lengths of time to assess the influence of count statistics on the calculation of absorbed dose. Comparisons between the local energy deposition method and the absorbed dose calculations were performed. RESULTS: Using a 2-mm full width at half maximum post-reconstruction Gaussian filter, the dosimetric accuracy was found to be similar to that found with no filter applied but also reduced noise. Larger filter sizes should not be used. An acquisition length of more than 10 min/bed reduces image noise but has no significant impact in the quantification of phantom or patient data for the digital photon counting PET. 3 iterations with 10 subsets were found suitable for large spheres whereas 1 iteration with 30 subsets could improve dosimetry for smaller spheres. CONCLUSION: The best choice of the combination of iterations and subsets depends on the size of the spheres. However, one should be careful on this choice, depending on the imaging conditions and setup. This study can be useful in this choice for future studies for more accurate 90Y post-dosimetry using a digital photon counting PET/CT.

3.
Phys Med ; 27(1): 1-10, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20615735

ABSTRACT

PURPOSE: In vivo dose verification is used to prevent major deviations between the prescribed dose and the dose really delivered to the patient. This work presents a quick and simple alternative method for verification of dose delivered to the patient using photon beams. During the treatment session, a transit dose is measured with the EPID and the dose in the patient is estimated from back projection of the portal dose. METHODS AND MATERIALS: The formalism for dose calculation is described. It is independent of the detector and has been validated for different beam energies using an ionization chamber (IC). Central axis doses estimated by this formalism were compared with measured dose. Subsequently, the IC was replaced by the EPID appropriately calibrated. The feasibility of the method and its applicability in clinical use has been evaluated on 3 8 patients treated with conformal therapy for various localizations. RESULTS: Ratios between stated and measured doses are reported. They are within the accepted tolerance of classical in vivo dosimetry (SD of 3.5%). CONCLUSIONS: The proposed method for in vivo dose verification is very simple to implement and to use in clinics. Measurements can be repeated during several sessions giving the opportunity to built new strategies for the validation by statistical evaluation of the data. The trending of in vivo dose along the treatment becomes also possible. The number of checkable beams is also increased by this method.


Subject(s)
Radiation Tolerance , Radiotherapy/methods , Algorithms , Calibration , Humans , Photons , Radiometry , Radiotherapy/instrumentation , Radiotherapy/standards , Radiotherapy/trends , Radiotherapy Dosage