Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-39004116

ABSTRACT

BACKGROUND: O'Driscoll popularized the principle of linked column fixation for distal humerus fractures. Despite the linked column concept being widely accepted, there are few reported techniques to accomplish this goal. A novel device was designed based on the principles of linked columns. An interlocking beam is used to connect the medial and lateral plates, creating a unified fixed angle construct. Our primary objective was to report clinical outcomes across multiple institutions for a linking beam used in distal humerus fracture fixation. METHODS: A retrospective series was collected from five institutions for the TiBeam (Skeletal Dynamics, Miami, FL, USA) with a minimum follow-up of six months. Acute and chronic treatment of distal humerus fracture patterns, and all plate configurations were included for analysis. RESULTS: A total of 36 cases were collected at a mean age of 52 years and a mean follow-up of 19.3 months. AO C-type fractures were 56% of the series. The median MEPS was 85 (IQR 76.3 to 90), the median DASH was 21.4 (IQR 15.9 to 30), and the median VASa was 3.5 (IQR 2 to 5). An olecranon osteotomy was used in 86% of cases and an anatomic plate was used for fixation of the osteotomy in 94% of those cases. There were three cases of olecranon plate removal for a rate across the series of 13.7%. DISCUSSION: Our short-term results demonstrate satisfactory clinical outcomes with low rates of revision for distal humerus fracture fixed with a linking beam. Further, the rate of removal for the olecranon osteotomy plate was lower than historical reports for aggregate methods of osteotomy fixation.

2.
Hand (N Y) ; : 15589447231151434, 2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36752100

ABSTRACT

BACKGROUND: Revision of radial head arthroplasty (RHA) may be indicated in cases of prosthesis loosening and malposition. Inherent difficulties in revision surgery include poor bone stock and disrupted soft tissue envelope. Although cases of RHA used for revision of failed RHA are rare, there is reasonable expectation for increasing frequency of these cases due to the increasing incidence of primary RHA. Furthermore, there is an increasing demand for postoperative recovery of function; thus, surgeons may consider revising a failed RHA to a new RHA. We report on series of failed RHA which were revised to a new radial head prosthesis. METHODS: A retrospective review was performed at multiple institutions for a single radial head prosthesis used for revision of a failed radial head prosthesis. Clinical and radiographic outcomes were collected with a minimum of 1 year of follow-up. RESULTS: Across 11 patients at a mean follow-up of 45.1 months, the mean Mayo Elbow Performance Score was 81.7; mean Disabilities of the Arm, Shoulder, and Hand scores were 24.4; and mean Visual Analog Scale for pain was 0.6. Radiographic analysis yielded no evidence of capitellar wear or stem loosening. CONCLUSION: A radial head prosthesis can produce satisfactory results when used for revision of a failed prosthesis. Inherent difficulties in revision surgery include the potential for reduced bone stock and a disrupted soft tissue envelope. Elements of prosthesis design which may contribute to effectively managing revision surgery include a long stem with in-growth surface and prosthetic head alignment to the axis of forearm rotation.

3.
J Shoulder Elbow Surg ; 26(1): 125-132, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27939280

ABSTRACT

BACKGROUND: Our primary efficacy objective was to evaluate the effectiveness of the internal joint stabilizer of the elbow (IJS-E) in maintaining concentric location of the elbow during and after removal of the device in the treatment of persistent or recurrent instability after elbow fracture or dislocations, or both. The secondary study objectives were to assess range of motion, Broberg-Morrey functional score, Broberg-Morrey categorical rating, the Disabilities of the Arm, Shoulder and Hand score, and the rate of complications and adverse events after the use of IJS-E. METHODS: Twenty-four patients were studied in a multicenter, nonrandomized, prospective, single-arm study. The IJS-E was used to provide temporary stabilization of the elbow joint and allow a functional range of motion while ligaments and fractures healed. RESULTS: The elbow remained concentrically aligned in 23 of 24 patients. One coronoid-deficient elbow did not maintain concentric reduction. At the last evaluation a minimum of 6 months after device removal, the mean arc of elbow flexion was 119° (range, 80°-150°; standard deviation [SD], 18°), and the mean arc of forearm rotation was 151° (range, 90°-190°; SD, 24°). The mean and median Broberg-Morrey scores were 93 and 97, respectively. Categorically the results were excellent in 14, good in 8, fair in 1, and poor in 1. The mean Disabilities of the Arm, Shoulder and Hand score was 16 (range, 0-68; SD, 18). CONCLUSION: The IJS-E maintains concentric reduction, allows elbow motion, and avoids the inconveniences and pin problems of percutaneous fixation.


Subject(s)
Elbow Joint , Fracture Fixation, Internal/instrumentation , Intra-Articular Fractures/surgery , Joint Dislocations/surgery , Joint Instability/surgery , Adult , Aged , Device Removal , Female , Humans , Intra-Articular Fractures/complications , Intra-Articular Fractures/diagnostic imaging , Joint Dislocations/complications , Joint Dislocations/diagnostic imaging , Joint Instability/diagnostic imaging , Joint Instability/etiology , Male , Middle Aged , Prospective Studies , Radiography , Range of Motion, Articular , Recovery of Function , Treatment Outcome
4.
J Reconstr Microsurg ; 25(2): 117-24, 2009 Feb.
Article in English | MEDLINE | ID: mdl-18925551

ABSTRACT

Chronic nonunions of the humerus remain a challenging problem. We reviewed 13 cases of chronic nonunion of the humerus resulting from trauma or osteomyelitis treated with vascularized fibula transfer after failure of conventional treatment. Patient averages were 35 years of age, follow-up of 19 months, and 4.2 prior operations. Healing was obtained in 12 of 13 (92%) patients with an average healing time of 18 weeks and graft length of 12.5 cm. In total, 11 of 12 (91%) patients who united had good to excellent range of motion of their shoulder and elbow. There were eight complications in 7 of 13 patients (54%). Two patients developed fractures of the graft, and three had superficial infections at the harvest site requiring operative debridement. Two patients had median neurapraxia that resolved by 4 months. Two patients complained of intermittent pain at the donor site. No significant correlations were found between time to heal and other covariates.


Subject(s)
Fibula/transplantation , Fractures, Ununited/surgery , Humeral Fractures/surgery , Adolescent , Adult , Aged , Child , Female , Fibula/blood supply , Follow-Up Studies , Fracture Healing/physiology , Humans , Male , Middle Aged , Postoperative Complications , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...