J Neurosurg Spine ; 38(1): 115-125, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36152329

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of a posterior facet replacement device, the Total Posterior Spine (TOPS) System, for the treatment of one-level symptomatic lumbar stenosis with grade I degenerative spondylolisthesis. Posterior lumbar arthroplasty with facet replacement is a motion-preserving alternative to lumbar decompression and fusion. The authors report the preliminary results from the TOPS FDA investigational device exemption (IDE) trial. METHODS: The study was a prospective, randomized controlled FDA IDE trial comparing the investigational TOPS device with transforaminal lumbar interbody fusion (TLIF) and pedicle screw fixation. The minimum follow-up duration was 24 months. Validated patient-reported outcome measures included the Oswestry Disability Index (ODI) and visual analog scale (VAS) for back and leg pain. The primary outcome was a composite measure of clinical success: 1) no reoperations, 2) no device breakage, 3) ODI reduction of ≥ 15 points, and 4) no new or worsening neurological deficit. Patients were considered a clinical success only if they met all four measures. Radiographic assessments were made by an independent core laboratory. RESULTS: A total of 249 patients were evaluated (n = 170 in the TOPS group and n = 79 in the TLIF group). There were no statistically significant differences between implanted levels (L4-5: TOPS, 95% and TLIF, 95%) or blood loss. The overall composite measure for clinical success was statistically significantly higher in the TOPS group (85%) compared with the TLIF group (64%) (p = 0.0138). The percentage of patients reporting a minimum 15-point improvement in ODI showed a statistically significant difference (p = 0.037) favoring TOPS (93%) over TLIF (81%). There was no statistically significant difference between groups in the percentage of patients reporting a minimum 20-point improvement on VAS back pain (TOPS, 87%; TLIF, 64%) and leg pain (TOPS, 90%; TLIF, 88%) scores. The rate of surgical reintervention for facet replacement in the TOPS group (5.9%) was lower than the TLIF group (8.8%). The TOPS cohort demonstrated maintenance of flexion/extension range of motion from preoperatively (3.85°) to 24 months (3.86°). CONCLUSIONS: This study demonstrates that posterior lumbar decompression and dynamic stabilization with the TOPS device is safe and efficacious in the treatment of lumbar stenosis with degenerative spondylolisthesis. Additionally, decompression and dynamic stabilization with the TOPS device maintains segmental motion.


Subject(s)
Pedicle Screws , Spinal Fusion , Spondylolisthesis , Humans , Spondylolisthesis/diagnostic imaging , Spondylolisthesis/surgery , Spinal Fusion/methods , Treatment Outcome , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Prospective Studies , Constriction, Pathologic/surgery , Back Pain/surgery , Arthroplasty , Minimally Invasive Surgical Procedures , Retrospective Studies
2.
J Neurooncol ; 123(2): 259-66, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25947286

ABSTRACT

Temozolomide (TMZ) and BCNU have demonstrated anti-glioma synergism in preclinical models. We report final data from a prospective, multi-institutional study of BCNU wafers and early TMZ followed by radiation therapy with TMZ in patients with newly diagnosed malignant glioma. 65 patients were consented in 4 institutions, and 46 patients (43 GBM, 3 AA) were eligible for analysis. After resection and BCNU wafer placement, TMZ began on day four postoperatively. Radiation and TMZ (RT/TMZ) were then administered, followed by monthly TMZ at 200 mg/m2 for the first 26 patients, which was reduced to 150 mg/m2 for the remaining 20 patients. Non-hematologic toxicities were minimal. Nine of 27 patients (33 %) who received 200 mg/m2 TMZ, but only 1 of 20 (5 %) who received 150 mg/m2, experienced grade 3/4 thrombocytopenia. Median progression free survival (PFS) and overall survival (OS) period was 8.5 and 18 months, respectively. The 1-year OS rate was 76 %, which is a significant improvement compared with the historical control 1-year OS rate of 59 % (p = 0.023). However, there was no difference in 1-year OS compared with standard RT/TMZ (p = 0.12) or BCNU wafer followed by RT/TMZ (p = 0.87) in post hoc analyses. Early post-operative TMZ can be safely administered with BCNU wafers following resection of malignant glioma at the 150 mg/m2 dose level. Although there was an OS benefit compared to historical control, there was no indication of benefit for BCNU wafers and early TMZ in addition to standard RT/TMZ or early TMZ in addition to regimens of BCNU wafers followed by RT/TMZ.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Brain Neoplasms/mortality , Brain Neoplasms/therapy , Glioma/mortality , Glioma/therapy , Adult , Aged , Brain Neoplasms/pathology , Carmustine/administration & dosage , Combined Modality Therapy , Dacarbazine/administration & dosage , Dacarbazine/analogs & derivatives , Female , Follow-Up Studies , Glioma/pathology , Humans , Male , Middle Aged , Neoplasm Grading , Postoperative Period , Prognosis , Prospective Studies , Radiotherapy Dosage , Survival Rate , Temozolomide
3.
J Neurosurg Spine ; 4(1): 31-5, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16506463

ABSTRACT

OBJECT: The authors report on a prospective randomized controlled multicenter trial in which they compared the clinical outcomes obtained in patients who underwent the placement of a Bryan Cervical Disc System with those obtained in patients who underwent anterior cervical discectomy and fusion (ACDF). In the present study, they evaluated the safety and effectiveness of the artificial disc based on data obtained at a single investigational site. METHODS: Patients with primary, single-level cervical disc disease producing radiculopathy and/or myelopathy were randomized prospectively to undergo anterior cervical discectomy with either fusion or artificial disc placement. The patients were evaluated with pre- and postoperative serial radiographic studies; the authors also evaluated neck disability indices, visual analog scale scores for pain, 36-Item Short Form Health Survey scores, and neurological status at 1.5, 3, 6, 12, and 24 months. Analysis of the early results obtained in the 33 patients indicated an absence of device-related complications. Preliminary analysis revealed that improvement in all clinical outcome measures was excellent for both treatment groups; however, in patients treated with the artificial cervical disc, motion at the treated level was maintained. CONCLUSIONS: The preliminary results documented at this investigational site are encouraging. Evaluation of data acquired in the Bryan disc treatment group showed that improvements in the clinical parameters were similar to those in the fusion group. Additionally in the artificial disc-treated group, there was radiographic evidence that motion was maintained. It is theorized that motion preservation may potentially reduce the rate of adjacent-level cervical disc disease that has been documented in patients who undergo ACDF.


Subject(s)
Arthroplasty, Replacement/methods , Intervertebral Disc , Prosthesis Implantation , Spinal Fusion/instrumentation , Spinal Fusion/methods , Adult , Arthroplasty, Replacement/instrumentation , Cervical Vertebrae , Female , Humans , Male , Prospective Studies , Prosthesis Design , Radiculopathy/etiology , Range of Motion, Articular , Spinal Cord Diseases/etiology , Treatment Outcome