Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Biomedicines ; 10(6)2022 Jun 13.
Article in English | MEDLINE | ID: mdl-35740422

ABSTRACT

The aim of this study was to develop a deformable image registration (DIR)-based offline ART protocol capable of identifying significant dosimetric changes in the first treatment fractions to determine when adaptive replanning is needed. A total of 240 images (24 planning CT (pCT) and 216 kilovoltage cone-beam CT (CBCT)) were prospectively acquired from 24 patients with prostate adenocarcinoma during the first three weeks of their treatment (76 Gy in 38 fractions). This set of images was used to plan a hypofractionated virtual treatment (57.3 Gy in 15 fractions); correlation with the DIR of pCT and each CBCT allowed to translate planned doses to each CBCT, and finally mapped back to the pCT to compare with those actually administered. In 37.5% of patients, doses administered in 50% of the rectum (D50) would have exceeded the dose limitation to 50% of the rectum (R50). We first observed a significant variation of the planned rectal volume in the CBCTs of fractions 1, 3, and 5. Then, we found a significant relationship between the D50 accumulated in fractions 1, 3, and 5 and the lack of compliance with the R50. Finally, we found that a D50 variation rate [100 × (administered D50 − planned D50/planned D50)] > 1% in fraction three can reliably identify variations in administered doses that will lead to exceeding rectal dose constraint.

2.
PLoS One ; 14(3): e0213253, 2019.
Article in English | MEDLINE | ID: mdl-30856183

ABSTRACT

1. BACKGROUND & PURPOSE: Investigate the applicability of a series of detectors in small field dosimetry and the possible differences between their responses to FF and FFF beams. This work extends upon the series of detectors used by other authors to also include metal-oxide-semiconductor field-effect transistors (MOSFETs) detectors and radiochromic film. We also included a later correction of output factors (OFs) recommended by the recently published IAEA´s code of practice TRS 483 on dosimetry of small static fields used in external beam radiotherapy. 2. MATERIALS & METHODS: The OFs, profiles, and PDDs of 6 MV and 6 MV FFF beams were measured with 11 different detectors using field sizes between 0.6 × 0.6 cm2 and 10 × 10 cm2. 3. RESULTS: The OFs of the FFF beams were lower than those of the FF beams for field sizes larger than 3 × 3 cm2 but higher for field sizes smaller than 3 × 3 cm2. After applying the IAEA´s TRS 483 corrections, the final OFs were compatible with our initial results when considering uncertainties involved. Small-volume detectors are preferable for measuring the penumbra of these small fields where this attribute is higher in the crossline direction than in the inline direction. The R100 of equivalent-quality FFF beams was higher compared to the corresponding flattened beams. 4. CONCLUSIONS: We observed no difference for the dose responses between 6 MV and 6 MV FFF beams for any of the detectors. OF results, profiles and PDDs were clearly consistent with the previously published literature regarding the Versa HD linac. Correcting our first OFs, taken as ratio of detector charges, with the IAEA´s TRS 483 corrections to obtain the final OFs, did not make the former significantly different.


Subject(s)
Radiometry/methods , Humans , Particle Accelerators , Phantoms, Imaging , Radiometry/instrumentation , Transistors, Electronic
SELECTION OF CITATIONS
SEARCH DETAIL
...