Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Curr Mol Med ; 15(2): 176-83, 2015.
Article in English | MEDLINE | ID: mdl-25732147

ABSTRACT

Aberrant function of glutamatergic pathways is likely to underlie the pathology of schizophrenia. Evidence of oxidative stress in the disease pathology has also been reported. N-Acetylaspartate (NAA) is metabolically linked to both cascades and may be a key marker in exploring the interconnection of glutamatergic pathways and oxidative stress. Several studies have reported positive correlation between the levels of NAA and Glx (the sum of glutamate and glutamine) in several brain regions in healthy subjects, by using proton magnetic resonance spectroscopy ([(1)H]MRS). Interestingly, one research group recently reported decoupling of the relationship between NAA and Glx in the hippocampus of patients with schizophrenia. Here we report levels of NAA and Glx measured using [(1)H]MRS, relative to the level of creatine (Cr) as an internal control. The dorsolateral prefrontal cortex (DLPFC) and anterior cingulate cortex (ACC) in 25 patients with schizophrenia and 17 matched healthy controls were studied. In DLPFC, NAA/Cr and Glx/Cr were significantly positively correlated in healthy controls after correction for the effect of age and smoking status and after correction for multiple comparisons (r= 0.627, P= 0.017). However, in patients with schizophrenia, the positive correlation between NAA/Cr and Glx/Cr was not observed even after correcting for these two variables (r= -0.330, P= 0.124). Positive correlation between NAA/Cr and Glx/Cr was not observed in the ACC in both groups. Decoupling of NAA and Glx in the DLPFC may reflect the interconnection of glutamatergic pathways and oxidative stress in the pathology of schizophrenia, and may possibly be a biomarker of the disease.


Subject(s)
Aspartic Acid/analogs & derivatives , Glutamic Acid/metabolism , Gyrus Cinguli/metabolism , Prefrontal Cortex/metabolism , Schizophrenia/diagnosis , Schizophrenia/metabolism , Adult , Aspartic Acid/metabolism , Case-Control Studies , Creatine/metabolism , Female , Glutamine/metabolism , Gyrus Cinguli/pathology , Humans , Male , Neuropsychological Tests , Oxidative Stress , Prefrontal Cortex/pathology , Proton Magnetic Resonance Spectroscopy , Schizophrenia/pathology
2.
Int J Obes (Lond) ; 32(1): 100-11, 2008 Jan.
Article in English | MEDLINE | ID: mdl-17700582

ABSTRACT

OBJECTIVE: To examine five available software packages for the assessment of abdominal adipose tissue with magnetic resonance imaging, compare their features and assess the reliability of measurement results. DESIGN: Feature evaluation and test-retest reliability of softwares (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision) used in manual, semi-automated or automated segmentation of abdominal adipose tissue. SUBJECTS: A random sample of 15 obese adults with type 2 diabetes. MEASUREMENTS: Axial T1-weighted spin echo images centered at vertebral bodies of L2-L3 were acquired at 1.5 T. Five software packages were evaluated (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision), comparing manual, semi-automated and automated segmentation approaches. Images were segmented into cross-sectional area (CSA), and the areas of visceral (VAT) and subcutaneous adipose tissue (SAT). Ease of learning and use and the design of the graphical user interface (GUI) were rated. Intra-observer accuracy and agreement between the software packages were calculated using intra-class correlation. Intra-class correlation coefficient was used to obtain test-retest reliability. RESULTS: Three of the five evaluated programs offered a semi-automated technique to segment the images based on histogram values or a user-defined threshold. One software package allowed manual delineation only. One fully automated program demonstrated the drawbacks of uncritical automated processing. The semi-automated approaches reduced variability and measurement error, and improved reproducibility. There was no significant difference in the intra-observer agreement in SAT and CSA. The VAT measurements showed significantly lower test-retest reliability. There were some differences between the software packages in qualitative aspects, such as user friendliness. CONCLUSION: Four out of five packages provided essentially the same results with respect to the inter- and intra-rater reproducibility. Our results using SliceOmatic, Analyze or NIHImage were comparable and could be used interchangeably. Newly developed fully automated approaches should be compared to one of the examined software packages.


Subject(s)
Abdominal Fat/pathology , Diagnostic Imaging/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Obesity/diagnosis , Software Validation , Aged , Diagnostic Imaging/standards , Female , Humans , Magnetic Resonance Imaging/standards , Male , Middle Aged , Observer Variation , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...