Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
Add more filters










Publication year range
1.
Article in English | MEDLINE | ID: mdl-37992148

ABSTRACT

BACKGROUND: Hierarchical micro-nano structured topography along with surface chemistry modifications of dental implants have been suggested to positively contribute to the osseointegration process. However, the effect of such surface modifications on the molecular response as well as bone formation rate and quality are still unclear, especially in the early healing period. This study aimed to evaluate the effect of coating a double acid etched (DAE) implant surface with nano-sized (20 nm) hydroxyapatite (Nano) with respect to gene expression, histologic parameters, and nanomechanical properties when compared to DAE control at 1 and 2 weeks after implant placement in a rodent femur model. MATERIAL AND METHODS: Expression of bone-related genes was determined by qRT-PCR (Col-I, Runx-2, Osx, Opn, Ocn, Alp). Histomorphometric evaluation of bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) within implant threads was performed using photomicrographs after histologic processing. Mechanical properties, reduced elastic modulus and hardness, were determined through nanoindentation. RESULTS: At 1 week, the Nano group demonstrated significantly higher expression of Col-I and Ocn compared to the DAE group, indicating upregulation of osteoprogenitor and osteoblast differentiation genes. At 2 weeks, Nano surface further exhibited enhanced gene expression of Col-I and Osx in comparison to the DAE surface, suggesting an increased mineralization of the newly formed bone. Nanoindentation analysis revealed that the Nano group presented no significant difference on the ranks of reduced elastic modulus and hardness compared to DAE for both timepoints. Histomorphometric analysis yielded no significant difference in the percentage of BIC and BAFO between the Nano and DAE surfaces at 1 and 2 weeks. However, Nano implants did present a higher mean value, ~50%, of BIC compared to DAE, ~30%, after 2 weeks in vivo. CONCLUSIONS: While no significant differences were observed in the amount and mechanical properties of newly formed bone, Nano surface positively and significantly increased the expression osteogenic genes compared to DAE surface at early healing periods.

2.
Clin Oral Implants Res ; 34(11): 1217-1229, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37565379

ABSTRACT

OBJECTIVE: To analyze the influence of titanium-base (straight [SSC]/angulated-screw-channel [ASC]) on failure-loads and bending-moments of two-piece ceramic and titanium-zirconium implants restored with monolithic-zirconia crowns after fatigue. MATERIALS AND METHODS: Thirty-two anterior monolithic-screw-retained zirconia crowns were divided into four groups (n = 8/group) according to the factors: (1) type of implant material: two-piece titanium-zirconium implant (Ti-Zr; control-group) versus two-piece ceramic implant (CI; test-group) and (2) type of titanium-base: SSC (0° angle) versus ASC (25°). An intact implant was used for field emission gun-scanning electronic microscopy (FEG-SEM) characterization and Raman spectroscopy for phase analyses and residual stress quantification. All samples were exposed to fatigue with thermodynamic loading (1.2-million-cycles, 49 N, 1.6 Hz, 5-55°C) at a 30° angle. Surviving specimens were loaded until failure (SLF) and bending moments were recorded. Failed samples were examined using light microscope and SEM. Statistical analyses included ANOVA and Mann-Whitney U-test. RESULTS: Raman-spectroscopy revealed the presence of residual compressive stresses. FEG-SEM revealed a roughened surface between threads and polished surface at the cervical-collar of the ceramic implant. All samples survived fatigue and were free of complications. Mean bending-moments (±SD) were: Ti-Zr-0: 241 ± 45 N cm, Ti-Zr-25: 303 ± 86 N cm, CI-0: 326 ± 58 N cm, CI-25: 434 ± 71 N cm. Titanium-base and implant-material had significant effects in favor of ASC titanium bases (p = .001) and ceramic-implants (p < .001). Failure analysis after SLF revealed severe fractures in ceramic implants, whereas titanium implants were restricted to plastic deformation. CONCLUSIONS: Ceramic and titanium implants exhibited high reliability after fatigue, with no failures. From a mechanical perspective, titanium bases with ASC can be recommended for both ceramic and titanium implants and are safe for clinical application.


Subject(s)
Dental Implants , Zirconium , Zirconium/chemistry , Titanium/chemistry , Reproducibility of Results , Materials Testing , Dental Abutments , Dental Implant-Abutment Design , Dental Restoration Failure , Ceramics/chemistry , Crowns , Bone Screws
3.
Heliyon ; 9(7): e18021, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37496908

ABSTRACT

Scapula tip flaps have been introduced in the literature as an ideal surgical treatment option for large defects in the horizontal plane of the maxilla. This article aims to present a unique step by step protocol for a near total maxillectomy with a pterygoid bone resection and consecutive microvascular reconstruction with a harvested scapula tip flap. The protocol includes immediate placement of extra-short implants in donor bone with the aid of Virtual Surgical Planning (VSP), and an in-house 3D printing of medical 3D models and surgical guides. So far, there has been no presented surgical technique combining immediate implant placement in the scapula region with simultaneous microvascular repair. This technique allows: tumour resection; flap harvesting; extra-short implant placements and reconstruction to be performed in one simultaneous procedure. The technique is presented with illustrations, VSP (presented on videos), radiographs, and surgical findings. We discovered that this refinement of the scapula tip surgery has enabled reconstructive procedures to be performed at the same time as implant placements, providing expedited functional and aesthetic outcomes in selected cases. Moreover, modification of the surgical technique could enhance the competence of the oropharyngeal edge. In conclusion, this new surgical protocol utilizing VSP, 3D models and simultaneous extra-short implant placement provides indispensable advantages for such a complicated surgical procedures, while significantly shortening the duration of surgery.

4.
Med Oral Patol Oral Cir Bucal ; 28(1): e48-e55, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36173722

ABSTRACT

BACKGROUND: Successful osseointegration of endosteal dental implants has been attributed to implant design, including the macro-, micro- and nano- geometric properties. Based on current literature pertaining to implant design, the resultant cellular and bone healing response is unknown when the thread thickness of the implants is increased, resulting in an increased contact area in implants designed with healing chambers. The aim of this study was to evaluate the effect of two implant designs with different thread profiles on the osseointegration parameters and implant stability at 3- and 6-weeks in vivo using a well-established preclinical dog model. MATERIAL AND METHODS: A total of 48 type V Ti alloy implants were divided in two groups according to their thread design (D1= +0.1x/mm and D2= +0.15x/mm) and placed in an interpolated fashion into the radii of six beagles. Insertion torque was measured at time of placement, radii were extracted for histological processing following 3- and 6-week healing intervals. Histologic and histomorphometric analyses were performed in terms of bone to implant contact (%BIC) and bone area fraction occupancy within implant threads (%BAFO). Statistical analyses were performed through a linear mixed model with fixed factors of time and implant thread design. RESULTS: Surface roughness analysis demonstrated no significant differences in Sa and Sq between D1 and D2 implant designs, which confirmed that both implant designs were homogenous except for their respective thread profiles. For insertion torque, statistically significant lower values were recorded for D1 in comparison to D2 (59.6 ± 11.1 and 78.9 ± 10.1 N⋅cm, respectively). Furthermore, there were no significant differences with respect to histological analysis and histomorphometric parameters, between D1 and D2 at both time points. CONCLUSIONS: Both thread profiles presented equivalent potential to successfully osseointegrate in the osteotomies, with D2 yielding higher mechanical retention upon placement without detrimental bone resorption.


Subject(s)
Dental Implants , Osseointegration , Dogs , Animals , Torque , Dental Prosthesis Design , Dental Implantation, Endosseous/methods , Surface Properties
5.
Oper Dent ; 47(6): 701-708, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36442228

ABSTRACT

OBJECTIVE: Considering that misfit is a significant predictor of the clinical success of indirect restorations, the objective of this study was to evaluate the marginal and internal misfit of two computer-aided design and manufacturing (CAD/CAM) RMC ceramic materials used as occlusal veneers (OVs) of different thicknesses. METHODS AND MATERIALS: A CAD model of a mandibular first molar was obtained and OV preparations 0.5-, 1.0-, and 1.5-mm thick were modeled and milled in two different materials (n=10/group): resin nanoceramic (RNC) and polymer-infiltrated ceramic network (PICN). Using the same CAD model, tooth preparations were milled in fiber-reinforced epoxy resin (n=20/thickness). The marginal and internal misfit of the restorations was assessed by X-ray microtomography. The measurements of the marginal gap (MG) and absolute marginal discrepancy were performed in two locations on each slice, whereas internal gap (IG) measurements were performed at ten locations on each slice. The data obtained were analyzed using two-way analysis of variance and Tukey post-hoc tests (α=0.05). RESULTS: No significant effect was attributable to the material type or material-thickness interaction for the MG, absolute marginal discrepancy (AMD), or IG (p>0.05). However, the thickness significantly affected the IG of the restorations (p<0.05). CAD/CAM RNC and PICN systems presented similar MG and AMD for OVs 0.5-, 1.0-, and 1.5-mm thick. However, the IG varied between thicknesses.


Subject(s)
Ceramics , Computer-Aided Design , X-Ray Microtomography , Molar
6.
Med Oral Patol Oral Cir Bucal ; 27(5): e468-e475, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-35975804

ABSTRACT

BACKGROUND: We aimed to histomorphometrically evaluate the effects of Leucocyte-Platelet-Rich Fibrin (L-PRF), with and without the combination of a bone grafting material, for alveolar ridge preservation using an in vivo canine model. MATERIAL AND METHODS: Seven dogs (Female Beagles, ~18-month-old) were acquired for the study. L-PRF was prepared from each individual animal by drawing venous blood and spinning them through a centrifuge at 408 RCF-clot (IntrasSpin, Intra-Lock, Boca Raton, FL). L-PRF membranes were obtained from XPression fabrication kit (Biohorizons Implant Systems, Inc., AL, USA). A split mouth approach was adopted with the first molar mesial and distal socket defects treated in an interpolated fashion of the following study groups: 1) Empty socket (negative control); 2) OSS filled defect 3) L-PRF membrane; and 4) Mix of Bio-Oss® with L-PRF. After six weeks, samples were harvested, histologically processed, and evaluated for bone area fraction occupancy (BAFO), vertical/horizontal ridge dimensions (VRD and HRD, respectively), and area of coronal soft tissue infiltration. RESULTS: BAFO was statistically lower for the control group in comparison to all treatment groups. Defects treated with Bio-Oss® were not statistically different then defects treated solely with L-PRF. Collapsed across all groups, L-PRF exhibited higher degrees of BAFO than groups without L-PRF. Defects filled with Bio-Oss® and Bio-Oss® with L-PRF demonstrated greater maintenance of VRD relative to the control group. Collapsed across all groups, Bio-Oss® maintained the VRD and resulted in less area of coronal soft tissue infiltration compared to the empty defect. Soft tissue infiltration observed at the coronal area was not statistically different among defects filled with L-PRF, Bio-Oss®, and Bio-Oss® with L-PRF. CONCLUSIONS: Inclusion of L-PRF to particulate xenograft did not promote additional bone heading at 6 weeks in vivo. However, we noted that L-PRF alone promoted alveolar socket regeneration to levels comparable to particulate xenografts, suggesting its potential utilization for socket preservation.


Subject(s)
Bone Regeneration , Platelet-Rich Fibrin , Tooth Socket , Alveolar Process , Animals , Dogs , Female , Leukocytes , Molar , Tooth Extraction , Tooth Socket/surgery
7.
J Prosthodont ; 31(2): 136-146, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33870577

ABSTRACT

PURPOSE: This laboratory study analyzed the influence of retention mode (screw- vs cement retained) and fatigue application on the failure load of monolithic lithium-disilicate (LDS) implant-supported single crowns (ISSC). MATERIAL AND METHODS: A total of 72 samples of monolithic LDS (*Ivoclar Vivadent) ISSC were divided into three groups (n = 24) according to their type of retention mode: Group Ti-CAD: Titanium base (SICvantage CAD/CAM Abutment red (SIC invent AG), screw-retained milled monolithic LDS (IPS e.max CAD*); Group Ti-P: Titanium base (SICvantage CAD/CAM Abutment red), screw-retained pressed monolithic LDS (IPS e.max Press*) and Group Ti-Cust: Titanium base with cemented press LDS (IPS e.max Press*) crown on a LDS (IPS e.max Press*) custom abutment. A mandibular first molar implant-supported single crown model was investigated (Titanium implant: SICvantage-max, SIC invent AG, diameter: 4.2 mm, length: 11.5 mm). Half of each group (n = 12) w​ere exposed to fatigue with cyclic mechanical loading (F = 198 N, 1.2 million cycles) and simultaneous thermocycling (5-55°C). Single load to failure testing was performed, before (Subgroups Ti-CAD, Ti-P, and Ti-Cust) and after (Subgroups Ti-CAD-F, Ti-P-F, and Ti-Cust-F) fatigue. Weibull distribution was used to determine the characteristic strength and Weibull modulus differences between groups. Probability of survival at 900N load was calculated. RESULTS: No samples failed during fatigue. Characteristic strength values were as follow: Ti-CAD: 3259.5N, Ti-CAD-F: 2926N, Ti-P: 2763N, Ti-P-F: 2841N, Ti-Cust: 2789N, Ti-Cust-F: 2194N. Whereas no difference was observed between pressed or milled monolithic crowns cemented to Ti-base, regardless of loading condition, fatigue decreased the characteristic strength of crowns cemented to custom abutments. Probability of survival at 900 N was not significantly different between groups. CONCLUSIONS: Screw-retained pressed or milled monolithic LDS ISSC, cemented directly to Ti-base abutments or LDS crowns cemented to custom ceramic abutments resist physiological chewing forces after simulated 5-year aging in the artificial mouth and presented equally high probability of survival. However, a significant decrease in load to failure was observed in LDS crowns cemented to custom ceramic abutments after fatigue. Prospective clinical trials are needed to confirm the results of this laboratory investigation.


Subject(s)
Dental Implants , Materials Testing , Titanium , Ceramics , Computer-Aided Design , Crowns , Dental Abutments , Dental Porcelain , Dental Restoration Failure , Dental Stress Analysis , Humans , Prospective Studies
8.
J Mech Behav Biomed Mater ; 123: 104690, 2021 11.
Article in English | MEDLINE | ID: mdl-34385065

ABSTRACT

OBJECTIVE: To characterize the effects of aging on the nanomechanical properties and 3D surface topographical parameters of an experimental Zirconia Toughened Alumina (ZTA) composite compared to its respective individual counterpart materials. METHODS: Disk-shaped specimens comprised of three material groups were processed: 1) ZTA 70/30 (70% alumina reinforced with 30% second-generation 3Y-TZP); 2) Zpex (Second-generation 3Y-TZP), and; 3) Al2O3 (High purity Alumina) (n = 10/material, 12 × 1 mm). After synthesis, ceramic powders were pressed, the green-body samples were sintered and polished. Nanoindentation testing was performed to record elastic modulus (E) and hardness (H). Interferometry was utilized to assess 3D surface roughness parameters (Sa, Sq), while X-ray diffraction (XRD) and scanning electron microscope (SEM) assessed the crystalline content and microstructure. All tests were performed before and after simulated aging (134°C, 2.2 bar, 20 h). Statistical analyses were performed using linear mixed-model and least square difference pos-hoc tests (α = 5%). RESULTS: XRD spectra indicated increase of monoclinic peaks for Zpex (~18%) relative to ZTA 70/30 (~2.5%) after aging. Additionally, aging did not affect the surface roughness parameters of ZTA 70/30 and Al2O3, although a significant increase in Sa was recorded for Zpex following aging (~90 nm) (p < 0.001). Al2O3 yielded the highest H and E values (H:21 GPa, E: 254 GPa), followed by ZTA 70/30 (H: 13 GPa, E: 214 GPa) and Zpex (H:11 GPa, E: 167 GPa), all significantly different (p < 0.03). CONCLUSION: ZTA 70/30 and Al2O3 presented high hydrothermal stability with respect to all evaluated variables, where artificial aging significantly increased the monoclinic content and surface roughness of Zpex.


Subject(s)
Aluminum Oxide , Yttrium , Ceramics , Dental Materials , Materials Testing , Surface Properties , Zirconium
9.
Dent Mater ; 36(12): e365-e374, 2020 12.
Article in English | MEDLINE | ID: mdl-32943230

ABSTRACT

OBJECTIVE: To evaluate the effect of aging on the microstructural, mechanical, and optical properties of an experimental zirconia-toughened alumina composite with 80%Al2O3 and 20%ZrO2 (ZTA Zpex) compared to a translucent zirconia (Zpex) and Alumina. METHODS: Disc-shaped specimens were obtained by uniaxial and isostatic pressing the synthesized powders (n = 70/material). After sintering and polishing, half of the specimens underwent aging (20 h, 134 °C, 2.2 bar). Crystalline content and microstructure were evaluated using X-ray diffraction and scanning electron microscopy, respectively. Specimens underwent biaxial flexural strength testing to determine the characteristic stress, Weibull modulus, and reliability. Translucency parameter (TP) and Contrast ratio (CR) were calculated to characterize optical properties. RESULTS: ZTA Zpex demonstrated a compact surface with a uniform dispersion of zirconia particles within the alumina matrix, and typical alumina and zirconia crystalline content. ZTA Zpex and alumina exhibited higher CR and lower TP than Zpex. ZTA Zpex and Zpex showed significantly higher characteristic stress relative to alumina. While aging did not affect optical and mechanical properties of ZTA Zpex and alumina, Zpex demonstrated a significant increase in translucency, as well as a in characteristic stress. Alumina reliability was significantly lower than others at 300 MPa, ZTA Zpex and Zpex reliability decreased at 800 MPa, except for aged Zpex. SIGNIFICANCE: While aging did not affect the mechanical nor the optical properties of ZTA Zpex and alumina, it did alter both properties of Zpex. The results encourage further investigations to engineer ZTA as a framework material for long span fixed dental prostheses specially where darkened substrates, such as titanium implant abutments or endodontically treated teeth, demand masking.


Subject(s)
Aluminum Oxide , Zirconium , Ceramics , Dental Materials , Materials Testing , Reproducibility of Results , Surface Properties
10.
J Mech Behav Biomed Mater ; 104: 103659, 2020 04.
Article in English | MEDLINE | ID: mdl-32174417

ABSTRACT

PURPOSE: To synthesize a zirconia-toughened alumina (ZTA) composite with 85% alumina matrix reinforced by 15% zirconia and to characterize its optical and mechanical properties before and after artificial aging, to be compared with a conventional dental zirconia (3Y-TZP). MATERIAL AND METHODS: After syntheses, ZTA and 3Y-TZP powders were uniaxially and isostatically pressed. Green-body samples were sintered and polished to obtain 80 disc-shaped specimens per group (12 × 1 mm, ISO 6872:2015). The crystalline content and microstructure were characterized by X-ray diffraction (XRD) and scanning electron microscope (SEM). Optical properties were determined by the calculation of contrast ratio (CR) and translucency parameter (TP) using reflectance data. Mechanical properties were assessed by Vickers hardness, fracture toughness and biaxial flexural strength test (BFS). All analyses were conducted before and after artificial aging (20h, 134 °C, 0.22 MPa). Optical parameters and microhardness differences were evaluated through repeated-measures analysis of variance (p < 0.05). BFS data were analyzed using Weibull statistics (95% CI). RESULTS: The synthesis of the experimental ZTA composite was successful, with 98% of theoretical density, as shown in the SEM images. XRD patterns revealed typical zirconia and alumina crystalline phases. ZTA optical properties parameters showed no effect of aging, with a high CR and low TP values denoting a high masking-ability. 3Y-TZP presented lower masking-ability and aging significantly affected its optical properties. ZTA Vickers hardness, fracture toughness and Weibull parameters, including characteristic stress and Weibull modulus were not influenced by aging, while 3Y-TZP presented a significant decrease in characteristic stress and increase in fracture toughness after aging. The ZTA probability of survival for missions of 300 and 500 MPa was estimated at ~99% validating its use for 3-unit posterior fixed dental prostheses (FDP), and no different from conventional 3Y-TZP. At high-stress mission (800 MPa) a significant decrease in probability of survival was observed for aged 3Y-TZP (84%) and for immediate and aged ZTA (73 and 82% respectively). CONCLUSION: The ZTA composite presented a dense microstructure, with preservation of the crystalline content, optical and mechanical properties after artificial aging, which encourages future research to validate its potential use for large span FDP.


Subject(s)
Aluminum Oxide , Dental Prosthesis , Ceramics , Dental Materials , Materials Testing , Surface Properties , Yttrium , Zirconium
11.
Oper Dent ; 44(5): E244-E253, 2019.
Article in English | MEDLINE | ID: mdl-31265354

ABSTRACT

OBJECTIVES: This study assessed the fully stabilized zirconia (FSZ) Prettau Anterior, the partially stabilized zirconia (PSZ) Prettau, and the lithium disilicate IPS e.max CAD (LD) through microstructural and mechanical characterization and effect of thickness on fracture load of the ceramics. METHODS AND MATERIALS: Disk-shaped specimens (12 mm diameter and 1.2 mm thickness) were prepared for biaxial flexural strength (BFS) and Weibull statistics (n=30). For the fracture load static test (FLST) and Weibull statistics (n=30), disk-shaped specimens 12 mm in diameter and thicknesses of 0.5 mm, 1 mm, and 1.5 mm were cemented on an epoxy-resin substrate. RESULTS: BFS (MPa) results were PSZ: 683.0 ± 70.23; FSZ: 438.6 ± 64.1; and LD: 248.6 ± 37.3. One-way analysis of variance (ANOVA) for BFS was significant (p<0.001), and the Tukey post hoc test showed differences among all ceramics. There was difference in characteristic strength, but there was no difference in Weibull modulus. Two-way ANOVA for FLST was significant for ceramic (p<0001), thickness (p<0001), and interaction (p<0001). There was no difference among all ceramics at the 0.5 mm thickness. PSZ had higher values for the 1.0 mm and 1.5 mm thicknesses. LD of 1.5 mm thickness exhibited a higher FLST than FSZ. CONCLUSIONS: PSZ had the highest BFS, but when cemented on a substrate, all ceramics with 0.5 mm thickness behaved similarly. Despite the lower BFS, LD had a fracture load similar or superior to FSZ when cemented on a substrate.


Subject(s)
Ceramics , Dental Porcelain , Dental Stress Analysis , Materials Testing , Surface Properties , Zirconium
12.
Oper Dent ; 44(5): E254-E262, 2019.
Article in English | MEDLINE | ID: mdl-31172874

ABSTRACT

New resin-based restorative materials have been developed, such as computer-aided design/computer-aided manufacturing (CAD/CAM) and bulk-fill composites, as an alternative to traditional layering techniques. This study evaluated the biaxial flexural strength (BFS) before and after thermocycling of five different resin composites: one hybrid resin/ceramic CAD/CAM indirect material, Lava Ultimate CAD-CAM Restorative (LU, 3M Oral Care); a conventional composite, Filtek Z350 XT (Z350, 3M Oral Care); two bulk-fill composites, Tetric N-Ceram Bulk Fill (TBF, Ivoclar Vivadent) and Filtek Bulk Fill (FBF, 3M Oral Care); and one bulk-fill flow resin composite, Filtek Bulk Fill Flow (FBFF, 3M Oral Care). Three hundred disc-shaped specimens (6.5 mm in diameter and 0.5 mm thick) were fabricated and divided into five groups (n=30 for each composite and condition). The BFS test was performed in a universal testing machine at a crosshead speed of 0.5 mm/min immediately (i, 24 hours) and after thermocycling (a, 500 thermal cycles of 5°C to 55°C with a 30-second dwell time). The Weibull modulus (m) and characteristic stress (η) were calculated, and a contour plot was used (m vs η) to detect differences between groups (95% two-sided confidence intervals). Significantly higher characteristic stress was observed for LUi (286.6 MPa) and Z350i (248.8 MPa) compared to the bulk-fill groups (FBFi=187.9 MPa, FBFFi=175.9 MPa, TBFi=149.9 MPa), with no differences between LUi and Z350i. Thermocycling significantly decreased the characteristic stress of all groups with the highest values observed for LUa (186.7 MPa) and Z350a (188.9 MPa) and the lowest for FBFFa (90.3 MPa). Intermediate values were observed for FBFa (151.6 MPa) and TBFa (122.8 MPa). The Weibull modulus decreased only for FBFa compared to FBFi. Composition and thermocycling significantly influenced the biaxial flexural strength of resin composite materials.


Subject(s)
Composite Resins , Flexural Strength , Ceramics , Computer-Aided Design , Dental Materials , Materials Testing
13.
Oper Dent ; 42(1): E16-E23, 2017.
Article in English | MEDLINE | ID: mdl-27689769

ABSTRACT

The present study aimed to characterize the pattern and volume of polymerization shrinkage of flowable resin composites, including one conventional, two bulk fill, and one self-adhesive. Standardized class I preparations (2.5 mm depth × 4 mm length × 4 mm wide) were performed in 24 caries-free human third molars that were randomly divided in four groups, according to the resin composite and adhesive system used: group 1 = Permaflo + Peak Universal Bond (PP); group 2 = Filtek Bulk Fill + Scotchbond Universal (FS); group 3 = Surefil SDR + XP Bond (SX); and group 4 = Vertise flow self-adhering (VE) (n=6). Each tooth was scanned three times using a microcomputed tomography (µCT) apparatus. The first scan was done after the cavity preparation, the second after cavity filling with the flowable resin composite before curing, and the third after it was cured. The µCT images were imported into three-dimensional rendering software, and volumetric polymerization shrinkage percentage was calculated for each sample. Data were submitted to one-way analysis of variance and post hoc comparisons. No significant difference was observed among PP, FS, and VE. SX bulk fill resin composite presented the lowest values of volumetric shrinkage. Shrinkage was mostly observed along the occlusal surface and part of the pulpal floor. In conclusion, polymerization shrinkage outcomes in a 2.5-mm deep class I cavity were material dependent, although most materials did not differ. The location of shrinkage was mainly at the occlusal surface.


Subject(s)
Composite Resins/chemistry , Dental Restoration, Permanent/methods , X-Ray Microtomography , Dental Cements , Dentin-Bonding Agents , Humans , In Vitro Techniques , Materials Testing , Molar, Third , Polymerization , Random Allocation , Resin Cements , Surface Properties
14.
Adv Dent Res ; 28(1): 18-27, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26927484

ABSTRACT

The degree of interplay among variables in dental implant treatment presents a challenge to randomized clinical trials attempting to answer questions in a timely, unbiased, and economically feasible fashion. Further adding complexity to the different scenarios is the varied implant designs and related bone response, area of implantation, implant bulk material, restoration, abutments and related screws, fixation mode (screwed, fixed, or a combination), and horizontal implant-abutment matching geometry. This article critically appraises the most common mechanical testing methods used to characterize the implant-prostheses complex. It attempts to provide insight into the process of construction of an informed database of clinically relevant questions regarding preclinical evaluation of implant biomechanics and failure mechanisms. The use of single load to failure, fatigue life, fatigue limit, and step-stress accelerated life testing is discussed with emphasis on their deliverables, weaknesses, and strengths. Fractographic analysis and challenges in the correlation between laboratory- and in-service-produced failures of dental ceramics, resin composites, and titanium are introduced. In addition, examples are presented of mechanical characterization studies used in our laboratory to assess some implant-supported rehabilitation variables.


Subject(s)
Dental Implants , Dental Materials/chemistry , Dental Prosthesis Design , Dental Stress Analysis/methods , Biomechanical Phenomena , Dental Restoration Failure , Humans , In Vitro Techniques , Materials Testing , Stress, Mechanical , Time Factors
15.
J Dent Res ; 91(3): 305-10, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22205635

ABSTRACT

The present investigation hypothesized that the reliability of reduced-thickness monolithic lithium disilicate crowns is high relative to that of veneered zirconia (Y-TZP) and comparable with that of metal ceramic (MCR) systems. CAD/CAM first mandibular molar full-crown preparations were produced with uniform thicknesses of either 1.0-mm or 2.0-mm occlusal and axial reduction, then replicated in composite for standard crown dies. Monolithic 1.0-mm (MON) and 2.0-mm CAD/CAM lithium disilicate crowns, the latter with a buccal thin veneer (BTV) of 0.5 mm, were fabricated and then sliding-contact-fatigued (step-stress method) until failure or suspension (n = 18/group). Crack evolution was followed, and fractography of post mortem specimens was performed and compared with that of clinical specimens. Use level probability Weibull calculation (use load = 1,200 N) showed interval overlaps between MON and BTV. There was no significant difference between the Weibull characteristic failure loads of MON and BTV (1,535 N [90% CI 1,354-1,740] and 1,609 N [90% CI 1,512-1,712], respectively), which were significantly higher than that of Y-TZP (370 N [90% CI 322-427]) and comparable with that of MCR (1,304 N [90% CI 1,203-1,414]), validating the study hypothesis.


Subject(s)
Crowns , Dental Porcelain , Dental Veneers , Computer-Aided Design , Dental Prosthesis Design , Dental Restoration Failure , Dental Stress Analysis , Humans , Materials Testing , Metal Ceramic Alloys , Models, Dental , Survival Analysis , Yttrium , Zirconium
16.
J Dent Res ; 90(1): 104-8, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21057036

ABSTRACT

This study tested the hypothesis that all-ceramic core-veneer system crown reliability is improved by modification of the core design. We modeled a tooth preparation by reducing the height of proximal walls by 1.5 mm and the occlusal surface by 2.0 mm. The CAD-based tooth preparation was replicated and positioned in a dental articulator for core and veneer fabrication. Standard (0.5 mm uniform thickness) and modified (2.5 mm height lingual and proximal cervical areas) core designs were produced, followed by the application of veneer porcelain for a total thickness of 1.5 mm. The crowns were cemented to 30-day-aged composite dies and were either single-load-to-failure or step-stress-accelerated fatigue-tested. Use of level probability plots showed significantly higher reliability for the modified core design group. The fatigue fracture modes were veneer chipping not exposing the core for the standard group, and exposing the veneer core interface for the modified group.


Subject(s)
Crowns , Dental Porcelain/chemistry , Dental Prosthesis Design , Post and Core Technique , Yttrium/chemistry , Zirconium/chemistry , Cementation/methods , Computer-Aided Design , Dental Articulators , Dental Restoration Failure , Dental Stress Analysis/instrumentation , Dental Stress Analysis/methods , Dental Veneers , Friction , Humans , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Resin Cements/chemistry , Stress, Mechanical , Surface Properties , Time Factors , Tooth Preparation/methods , Water/chemistry
17.
J Dent Res ; 89(10): 1051-6, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20660796

ABSTRACT

Despite the increasing utilization of all-ceramic crown systems, their mechanical performance relative to that of metal ceramic restorations (MCR) has yet to be determined. This investigation tested the hypothesis that MCR present higher reliability over two Y-TZP all-ceramic crown systems under mouth-motion fatigue conditions. A CAD-based tooth preparation with the average dimensions of a mandibular first molar was used as a master die to fabricate all restorations. One 0.5-mm Pd-Ag and two Y-TZP system cores were veneered with 1.5 mm porcelain. Crowns were cemented onto aged (60 days in water) composite (Z100, 3M/ESPE) reproductions of the die. Mouth-motion fatigue was performed, and use level probability Weibull curves were determined. Failure modes of all systems included chipping or fracture of the porcelain veneer initiating at the indentation site. Fatigue was an acceleration factor for all-ceramic systems, but not for the MCR system. The latter presented significantly higher reliability under mouth-motion cyclic mechanical testing.


Subject(s)
Crowns , Dental Porcelain/chemistry , Metal Ceramic Alloys/chemistry , Zirconium/chemistry , Cementation/methods , Composite Resins/chemistry , Computer-Aided Design , Dental Prosthesis Design , Dental Restoration Failure , Dental Stress Analysis/instrumentation , Dental Veneers , Gold Alloys/chemistry , Humans , Materials Testing , Microscopy, Electron, Scanning , Molar , Palladium/chemistry , Resin Cements/chemistry , Silicon Dioxide/chemistry , Stress, Mechanical , Surface Properties , Time Factors , Tooth Preparation, Prosthodontic , Yttrium/chemistry
18.
J Dent Res ; 88(4): 382-6, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19407162

ABSTRACT

Clinically, zirconia-supported all-ceramic restorations are failing by veneer-chipping without exposing the zirconia interface. We hypothesized that mouth motion step-stress-accelerated fatigue testing of standardized dental crowns would permit this previously unrecognized failure mode to be investigated. Using CAD software, we imported the average dimensions of a mandibular first molar crown and modeled tooth preparation. The CAD-based tooth preparation was rapid-prototyped as a die for fabrication of zirconia core porcelain-veneered crowns. Crowns were bonded to aged composite reproductions of the preparation and aged 14 days in water. Crowns were single-cycle-loaded to failure or mouth-motion step-stress- fatigue-tested. Finite element analysis indicated high stress levels below the load and at margins, in agreement with only single-cycle fracture origins. As hypothesized, the mouth motion sliding contact fatigue resulted in veneer chipping, reproducing clinical findings allowing for investigations into the underlying causes of such failures.


Subject(s)
Crowns , Dental Porcelain , Dental Restoration Failure , Dental Stress Analysis , Finite Element Analysis , Computer Simulation , Mandible , Molar
19.
Dent Mater ; 25(9): 1122-7, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19395078

ABSTRACT

OBJECTIVE: To evaluate the mouth-motion step-stress fatigue behavior of two porcelain-zirconia all-ceramic crown systems. METHODS: The average dimensions of a mandibular first molar crown were imported into CAD software; a tooth preparation was modeled by reducing proximal walls by 1.5 mm and occlusal surface by 2.0 mm. The CAD-based tooth preparation was made by rapid prototyping and used as a master die to fabricate all-ceramic crowns with 1.0 mm porcelain veneered on 0.5 mm Y-TZP cores (LAVA veneer+LAVA frame, 3M/ESPE, and Vita veneer+CERCON frame, Dentsply). Crowns were cemented on aged (60 days in water) composite (Z100, 3M/ESPE) reproductions of the die. Three crowns from the LAVA group were subjected to single cycle load to failure for stress profile design; remainder subjected to step-stress mouth-motion fatigue (three step-stress profiles). All mechanical testing was performed by sliding a WC indenter of 6.25 mm diameter 0.7 mm lingually down the mesio-distal cusp. Master Weibull curves and reliability for missions of 50,000 cycles at 200 N load were calculated (Alta Pro 7, Reliasoft). RESULTS: Single load to failure showed fractures through the zirconia core. Reliability for a 200 N x 50K cycle mission was not significantly different between systems. In fatigue, failure occurred by formation of large chips within the veneer originating from the contact area without core exposure. CONCLUSIONS: LAVA and CERCON ceramic systems present similar fatigue behavior; fatigue loading of both systems reproduces clinically observed failure modes.


Subject(s)
Crowns , Dental Porcelain , Dental Stress Analysis , Yttrium , Zirconium , Bite Force , Computer-Aided Design , Dental Prosthesis Design , Dental Veneers , Humans , Materials Testing , Molar , Survival Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...