Results 1 - 20 de 235
Filter
1.
J Dent ; : 105148, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38909648

ABSTRACT

OBJECTIVE: This cohort study aimed to assess the incidence of somatosensory alterations after implant surgery using standardized quantitative and qualitative sensory testing. METHODS: 33 participants with single-tooth loss, undergoing immediate implant loading were included. Quantitative Sensory Testing (QST) and Qualitative Sensory Testing (QualST) were conducted at eight time points over a year (baseline to 1 year). Two-Way Repeated Measures ANOVA and post hoc Tukey test were used on QST values and Cochran Q test on QualST. RESULTS: The study revealed significant increase in thermal thresholds overtime. At the operated side, overall Cold Pain Threshold (extraoral: p=0.030; intraoral: p<0.001), and Cold Detection Threshold (intraoral: p<0.001) increased overtime. In contralateral region, maxilla Cold Detection Threshold (extraoral: p=0.024; intraoral: p=0.031), Warm Detection Threshold (extraoral: p=0.026; intraoral: p=0.047) and overall Cold Pain Threshold (extraoral and intraoral: p<0.001) also increased. QualST showed extraoral pinprick (p=0.032) and intraoral pinprick (p=0.000), cold (p=0.000) and touch (p=0.002) stimuli abnormalities overtime. CONCLUSIONS: Somatosensory alterations after implant surgery were detected in both quantitative and qualitative sensory assessments, but rapidly decreased during the first follow-ups, and then continuously until 1-year. CLINICAL SIGNIFICANCE: This study provides clinical and controlled evidence on the real effect of the somatosensory alterations overtime, leading to a better understanding of neurosensory behaviour after single-tooth dental implant rehabilitation.

2.
J Dent ; : 105137, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38901822

ABSTRACT

OBJECTIVES: To investigate vitamin-D levels effect on the survival/success and on marginal bone levels of dental implants. METHODS: Patients with peri-implant disease and healthy control patients with functionally loaded dental implants were included in this retrospective case-control study. Forty patients with 201 implants were in the diseased-cohort, while thirty-three patients with 90 implants were in the control-cohort. Patient blood 25(OH)D levels were assessed through quantitative blood test. The correlation between abnormal 25(OH)D levels and disease status of each patient was assessed using Fisher's exact tests. The correlation of each implant's outcomes with vitamin-D status was assessed using Kaplan-Meier survival analysis and Mann-Whitney U tests. RESULTS: Patients with blood 25(OH)D levels >70ng/mL (hypervitaminosis-D) had a 21.1-fold increase in the risk of implant failure or severe peri-implant bone loss regarding patients with intermediate (>30, ≤70ng/mL) levels. Kaplan-Meier survival analysis revealed that implants in the hypervitaminosis-D cohort had a survival probability of 73.7% (95% CI:56.5-84.5%) at 19-years after surgery, compared to 95% for implants in patients with intermediate 25(OH)D levels (95% CI:88.3-97.9%). Additionally, implants in the hypervitaminosis-D cohort lost bone faster than implants in the intermediate cohort. These results were specific to the patient cohort with elevated blood 25(OH)D levels and not observed in patients taking vitamin-D supplementation. The impact of hypervitaminosis-D was enriched for implants in the maxilla, and not as apparent for implants in the mandible. CONCLUSIONS: Blood 25(OH)D levels >70ng/mL were correlated with adverse implant outcomes, including implant failure and peri-implant bone loss, especially in the maxilla. CLINICAL RELEVANCE: These results suggest that hypervitaminosis D may be a previously unidentified risk factor for dental implant complications and should be further investigated to elucidate the underlying mechanism.

3.
Prim Dent J ; 13(2): 53-57, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38888075

ABSTRACT

A technique is outlined for utilising a polymeric composite reinforced with glass fibres in a three-dimensional mesh as a post-core in aesthetic cases. The clinical procedure involves obtaining an impression of the root canal space, scanning the definitive cast, and milling a fibre-reinforced composite post-core. Subsequently, the intra-radicular post-core is cemented using an adhesive resin cement. The use of custom-made computer-aided design-computer-aided manufacturing (CAD-CAM) fibre-reinforced composite post-core facilitates repairability, provides better adaptation to the root canal space, avoids uneven cement thickness, ensures chemical adhesion to resin cement, and promotes favourable aesthetics when combined with all-ceramic crowns.


Subject(s)
Composite Resins , Computer-Aided Design , Dental Prosthesis Design , Glass , Post and Core Technique , Humans , Composite Resins/chemistry , Glass/chemistry , Resin Cements/chemistry , Crowns , Esthetics, Dental , Dental Prosthesis Retention , Dental Materials/chemistry , Cementation
4.
J Mech Behav Biomed Mater ; 155: 106568, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38714003

ABSTRACT

PURPOSE: The strength of temporary restorations plays a vital role in full-mouth reconstruction, and it can be impacted by the aging process. The aim of this in vitro study was to evaluate the biaxial flexural strength and fractographic features of different resin-based materials submitted to thermal aging. MATERIAL AND METHODS: One hundred and ninety-two resin disc-shaped specimens (6.5 mm in diameter and 0.5 mm in thickness) were fabricated and divided into six experimental groups according to the resin-based materials (Filtek Bulk-Fill flowable resin; J-Temp temporary resin; and Fuji Lining glass ionomer cement) and aging process (before and after thermal cycling). Biaxial flexural strength test was performed using a universal testing machine at a crosshead speed of 0.5 mm/min before and after thermal cycling (5 °C and 55 °C, 5760 cycles, 30 s). The mechanical properties were assessed using Weibull parameters (characteristic strength and Weibull modulus) (n = 30). Fractured specimens were examined under a polarized light stereomicroscope to identify crack origin and propagation direction. The surface microstructure of the resin-based materials was assessed by scanning electron microscopy (n = 2). The Weibull modulus (m), characteristic strength, and reliability properties were calculated, and a contour plot was used to detect differences among groups (95% confidence interval). RESULTS: The Weibull modulus (m), characteristic strength, and reliability of the resin-based compounds were influenced by material type and thermal aging (p < 0.05). Weibull modulus (m) revealed no differences when comparing the materials and aging process (p > 0.05), except for the preceding aging period where Filtek Bulk-Fill exhibited higher values compared to J-Temp (p < 0.05). Filtek Bulk-Fill demonstrated superior characteristic strength and reliability compared to J-Temp and Fuji Lining before and after thermal cycling (p < 0.05). Fractography of the resin-based materials showed fractures originating from surface defects exposed to tensile side and their propagation toward the compressive side. Generally, no differences in surface microstructure were observed on micrographs before and after thermal aging for Filtek Bulk-Fill and Fuji Lining. However, the aging process developed flaws in J-Temp. CONCLUSION: Resin-based material composition resulted in different flexural strength performance, impacting the Weibull modulus (m), characteristic strength, and reliability of the resin-based restorations.


Subject(s)
Composite Resins , Flexural Strength , Materials Testing , Composite Resins/chemistry , Resins, Synthetic/chemistry , Temperature , Time Factors , Water/chemistry , Stress, Mechanical
5.
J Mech Behav Biomed Mater ; 154: 106533, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38598918

ABSTRACT

The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% Al2O3 and 20% ZrO2 was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C. After cooling and holder gluing, a stereolithography (STL) file was designed and uploaded to manufacture disk-shaped specimens projected to comply with ISO 6872:2015. Seventy specimens were produced through machining of the blocks, samples were sintered at 1600 °C and two-sided polished. Half of the samples were subjected to accelerated autoclave hydrothermal aging (20h at 134 °C and 2.2 bar). Immediate and aged samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Optical and mechanical properties were assessed by reflectance tests and by biaxial flexural strength test, Vickers indentation and fracture toughness, respectively. Samples produced by machining presented high density and smooth surfaces at SEM evaluation with few microstructural defects. XRD evaluation depicted characteristic peaks of alpha alumina and tetragonal zirconia and autoclave aging had no effect on the crystalline spectra of the composite. Optical and mechanical evaluations demonstrated a high masking ability for the composite and a characteristic strength of 464 MPa and Weibull modulus of 17, with no significant alterations after aging. The milled composite exhibited a hardness of 17.61 GPa and fracture toughness of 5.63 MPa m1/2, which remained unaltered after aging. The synthesis of ZTA blocks for CAD-CAM was successful and allowed for the milling of disk-shaped specimens using the grinding method of the CAD-CAM system. ZTA composite properties were unaffected by hydrothermal autoclave aging and present a promising alternative for the manufacture of infrastructures of fixed dental prostheses.


Subject(s)
Aluminum Oxide , Ceramics , Materials Testing , Aluminum Oxide/chemistry , Ceramics/chemistry , Surface Properties , Zirconium/chemistry , Computer-Aided Design , Dental Materials
6.
J Pers Med ; 14(4)2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38673010

ABSTRACT

There is limited information regarding implant and prosthetic survival after osseous microvascular free flap (OMFF). This case series aims to describe the placement of short and extra short implants in osseous microvascular free flaps to support prostheses, and present an up to 40-month retrospective follow-up. Short and extra short dental implants were placed in six fibula free flaps (FFF) and in two microvascular deep circumflex iliac artery (DCIA) flaps. In total, 27 short and extra short dental implants have been placed into two different types of free flaps. Kaplan-Meyer (K-M) survival analyses were performed to evaluate the survival and success outcomes of implants and prostheses. Out of the eight patients reconstructed with free flap, five were rehabilitated with prostheses, one patient has a temporary prosthesis, and two patients are in the process of prosthetic rehabilitation. Twenty-seven implants were followed up for up to 40 months, and K-M analyses showed 100% implant survival probability (95% confidence interval: 100%), while the implant success probability was 91.0% (95% confidence interval: 68.6-97.7%). Short and extra short dental implants placed in OMFF presented high survival and success rates in a retrospective case series after up to 40 months.

7.
ACS Biomater Sci Eng ; 10(5): 3097-3107, 2024 05 13.
Article in English | MEDLINE | ID: mdl-38591966

ABSTRACT

To develop a peri-implantitis model in a Gottingen minipig and evaluate the effect of local application of salicylic acid poly(anhydride-ester) (SAPAE) on peri-implantitis progression in healthy, metabolic syndrome (MS), and type-2 diabetes mellitus (T2DM) subjects. Eighteen animals were allocated to three groups: (i) control, (ii) MS (diet for obesity induction), and (iii) T2DM (diet plus streptozotocin for T2DM induction). Maxillary and mandible premolars and first molar were extracted. After 3 months of healing, four implants per side were placed in both jaws of each animal. After 2 months, peri-implantitis was induced by plaque formation using silk ligatures. SAPAE polymer was mixed with mineral oil (3.75 mg/µL) and topically applied biweekly for up to 60 days to halt peri-implantitis progression. Periodontal probing was used to assess pocket depth over time, followed by histomorphologic analysis of harvested samples. The adopted protocol resulted in the onset of peri-implantitis, with healthy minipigs taking twice as long to reach the same level of probing depth relative to MS and T2DM subjects (∼3.0 mm), irrespective of jaw. In a qualitative analysis, SAPAE therapy revealed decreased levels of inflammation in the normoglycemic, MS, and T2DM groups. SAPAE application around implants significantly reduced the progression of peri-implantitis after ∼15 days of therapy, with ∼30% lower probing depth for all systemic conditions and similar rates of probing depth increase per week between the control and SAPAE groups. MS and T2DM conditions presented a faster progression of the peri-implant pocket depth. SAPAE treatment reduced peri-implantitis progression in healthy, MS, and T2DM groups.


Subject(s)
Peri-Implantitis , Salicylic Acid , Swine, Miniature , Animals , Swine , Peri-Implantitis/drug therapy , Peri-Implantitis/pathology , Salicylic Acid/administration & dosage , Salicylic Acid/pharmacology , Salicylic Acid/therapeutic use , Diabetes Mellitus, Type 2/drug therapy , Disease Models, Animal , Disease Progression , Hyperglycemia/drug therapy , Male , Diabetes Mellitus, Experimental/drug therapy , Metabolic Syndrome/drug therapy , Metabolic Syndrome/metabolism , Dental Implants
8.
Clin Implant Dent Relat Res ; 26(2): 457-466, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38361143

ABSTRACT

PURPOSE: This retrospective study evaluated the effect of selected clinical and patient factors on survival, success, and peri-implant bone level changes of locking taper implants supporting molar crowns on Bicon's prefabricated shouldered abutments. METHODS: A total of 234 patients, who received 274 single molar crowns supported by locking taper implants were included in this retrospective study. Kaplan-Meier survival analysis was used to assess overall implant survival, prostheses survival, and success. Crowns were either monolithic (resin based) or bilayered (milled fiber-reinforced composite coping veneered with indirect composite). Early and late changes in marginal bone levels were plotted and analyzed with equivalence testing to compare the effects of different factors on crestal bone levels. RESULTS: At 9.5 years after implant surgery, the implant survival probability was 94.2%, the probability of prosthesis survival was 91.4%, and the probability of prosthetic success was 90.4%. Neither the use of different crown materials, nor the choice of monolithic versus bilayered crown construction, significantly affected the probability of prosthetic success. Marginal bone levels, on average, trended downwards towards the top of the implant within the first 2 years after functional loading, and remained stable on average, since then. Factors affecting bone levels included the use of nonsteroidal anti-inflammatory drugs, which precluded early implant bone loss; and subcrestal implant placement, which was linked to significantly higher long-term bone levels. CONCLUSION: The implant and abutment system studied resulted in high implant and prosthetic survival rates, regardless of prosthetic material used, with stable bone levels over time.


Subject(s)
Dental Implants, Single-Tooth , Dental Implants , Humans , Retrospective Studies , Crowns , Molar , Dental Restoration Failure , Dental Prosthesis, Implant-Supported , Follow-Up Studies
9.
J Biomed Mater Res B Appl Biomater ; 112(2): e35382, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38355936

ABSTRACT

This in vivo study evaluated the bone healing response around endosteal implants with varying surface topography/chemistry in a preclinical, large transitional model induced with metabolic syndrome (MS) and type-2 diabetes mellitus (T2DM). Fifteen Göttingen minipigs were randomly distributed into two groups: (i) control (normal diet, n = 5) and (ii) O/MS (cafeteria diet for obesity induction, n = 10). Following obesity induction, five minipigs from the obese/metabolic syndrome (O/MS) group were further allocated, randomly, into the third experimental group: (iii) T2DM (cafeteria diet + streptozotocin). Implants with different surface topography/chemistry: (i) dual acid-etched (DAE) and (ii) nano-hydroxyapatite coating over the DAE surface (NANO), were placed into the right ilium of the subjects and allowed to heal for 4 weeks. Histomorphometric evaluation of bone-to-implant contact (%BIC) and bone area fraction occupancy (%BAFO) within implant threads were performed using histomicrographs. Implants with NANO surface presented significantly higher %BIC (~26%) and %BAFO (~35%) relative to implants with DAE surface (%BIC = ~14% and %BAFO = ~28%, p < .025). Data as a function of systemic condition presented significantly higher %BIC (~28%) and %BAFO (~42%) in the control group compared with the metabolically compromised groups (O/MS: %BIC = 14.35% and %BAFO = 26.24%, p < .021; T2DM: %BIC = 17.91% and %BAFO = 26.12%, p < .021) with no significant difference between O/MS and T2DM (p > .05). Statistical evaluation considering both factors demonstrated significantly higher %BIC and %BAFO for the NANO surface relative to DAE implant, independent of systemic condition (p < .05). The gain increase of %BIC and %BAFO for the NANO compared with DAE was more pronounced in O/MS and T2DM subjects. Osseointegration parameters were significantly reduced in metabolically compromised subjects compared with healthy subjects. Nanostructured hydroxyapatite-coated surfaces improved osseointegration relative to DAE, regardless of systemic condition.


Subject(s)
Dental Implants , Diabetes Mellitus, Type 2 , Metabolic Syndrome , Humans , Swine , Animals , Osseointegration , Swine, Miniature , Surface Properties , Obesity , Durapatite/pharmacology , Titanium , Dental Implantation, Endosseous
10.
J Prosthodont Res ; 2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38171769

ABSTRACT

PURPOSE: The aim of this study was to establish and assess the validity of in silico models of biaxial flexural strength (BFS) tests to reflect in vitro physical properties obtained from two commercially available computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic blocks and one CAD/CAM resin composite block. METHODS: In vitro three-point bending and BFS tests were conducted for three CAD/CAM materials (n = 10): Katana Zirconia ST10 (raw material: super-translucent multilayered zirconia, ST10; Kuraray Noritake Dental, Niigata, Japan), Katana Zirconia HT10 (raw material: highly translucent multilayered zirconia, HT10; Kuraray Noritake Dental), and Katana Avencia N (AN; Kuraray Noritake Dental). Densities, flexural moduli, and fracture strains were obtained from the in vitro three-point bending test and used as an input for an in silico nonlinear finite element analysis. The maximum principal stress (MPS) distribution was obtained from an in silico BFS analysis. RESULTS: The elastic moduli of AN, HT10, and ST10 were 6.513, 40.039, and 32.600 GPa, respectively. The in silico fracture pattern of ST10 observed after the in silico evaluation was similar to the fracture pattern observed after the in vitro testing. The MPS was registered in the center of the tensile surface for all three specimens. The projections of the supporting balls were in the form of a triple asymmetry. CONCLUSIONS: The in silico approach established in this study provided an acceptable reflection of in vitro physical properties, and will be useful to assess biaxial flexural properties of CAD/CAM materials without wastage of materials.

11.
J Esthet Restor Dent ; 36(2): 373-380, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37605963

ABSTRACT

OBJECTIVE: To investigate the effect of ceramic thickness and dental substrate (enamel vs. dentin/enamel) on the survival rate and failure load of non-retentive occlusal veneers. MATERIALS AND METHODS: Human maxillary molars (n = 60) were divided into five test-groups (n = 12). The groups (named DE-1.5, DE-1.0, DE-0.5, E-1.0, E-0.5) differed in their dental substrate (E = enamel, DE = dentin/enamel) and restoration thickness (standard: 1.5 mm, thin: 1.0 mm, ultrathin: 0.5 mm). All teeth were prepared for non-retentive monolithic lithium-disilicate occlusal veneers (IPS e.max Press, Ivoclar). Restorations were adhesively cemented (Syntac Classic/Variolink II, Ivoclar) and exposed to thermomechanical fatigue (1.2 million cycles, 1.6 Hz, 49 N/ 5-55°C). Single load to failure was performed using a universal testing-machine. A linear-regression model was applied, pairwise comparisons used the Student-Newman-Keuls method (p < 0.05). RESULTS: Three dentin-based occlusal veneers (one DE-1.0, two DE-0.5) revealed cracks after fatigue exposure, which corresponds to an overall-survival rate of 95%. Load to failure resulted in the following ranking: 2142 N(DE-0.5) > 2105 N(E-1.0) > 2075 N(E-0.5) > 1440 N(DE-1.5) > 1430 N(DE-1.0). Thin (E-1.0) and ultrathin enamel-based occlusal veneers (E-0.5) revealed high failure loads and surpassed the standard thickness dentin-based veneers (DE-1.5) significantly (p = 0.044, p = 0.022). CONCLUSION: All tested monolithic lithium disilicate occlusal veneers obtained failure loads above physiological chewing forces. Thin and ultrathin enamel-based occlusal veneers outperformed the standard thick dentin-based occlusal veneers. CLINICAL SIGNIFICANCE: Minimally invasive enamel-based occlusal veneer restorations with non-retentive preparation design may serve as a conservative treatment option.


Subject(s)
Ceramics , Dental Porcelain , Humans , Survival Rate , Molar , Materials Testing , Dental Stress Analysis , Dental Veneers , Dental Restoration Failure
12.
J Esthet Restor Dent ; 36(2): 381-390, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37676053

ABSTRACT

PURPOSE: To evaluate the reliability and failure modes of ultrathin (0.5 mm) lithium disilicate, translucent and ultra-translucent zirconia crowns for posterior teeth restorations. MATERIALS AND METHODS: Fifty-four mandibular first molar crowns of three ceramic materials: (1) Lithium disilicate (e.max CAD, Ivoclar Vivadent), (2) 3Y-TZP (Zirconn Translucent, Vipi), and (3) 5Y-PSZ (Cercon XT, Dentsply Sirona), with 0.5 mm of thickness were milled and cemented onto composite resin abutments. Eighteen samples of each group were tested under mouth-motion step-stress accelerated life testing in a humid environment using mild, moderate, and aggressive profiles. Data was subjected to Weibull statistics. Use level curves were plotted and reliability was calculated for a given mission of 100,000 cycles at 100, 200, and 300 N. Fractographic analyses of representative samples were performed in scanning electron microscope. RESULTS: Beta (ß) values suggest that failures were dictated by material's strength for lithium disilicate and by fatigue damage accumulation for both zirconias. No significant differences were detected in Weibull modulus and characteristic strength among groups. At a given mission of 100,000 cycles at 100 N, lithium disilicate presented higher reliability (98% CB: 95-99) regarding 3Y-TZP and 5Y-PSZ groups (84% CB: 65%-93% and 79% CB: 37&-94%, respectively). At 200 N, lithium disilicate reliability (82% CB: 66%-91%) was higher than 5Y-PSZ (20% CB: 4%-44%) and not significantly different from 3Y-TZP (54% CB: 32%-72%). Furthermore, at 300 N no significant differences in reliability were detected among groups, with a notable reduction in the reliability of all materials. Fractographic analyses showed that crack initiated at the interface between the composite core and the ceramic crowns due to tensile stress generated at the intaglio surface. CONCLUSIONS: Ultrathin lithium disilicate crowns demonstrated higher reliability relative to zirconia crowns at functional loads. Lithium disilicate and zirconia crown's reliability decreased significantly for missions at higher loads and similar failure modes were observed regardless of crown material. The indication of 0.5 mm thickness crowns in high-load bearing regions must be carefully evaluated. CLINICAL SIGNIFICANCE: Ultraconservative lithium disilicate and zirconia crowns of 0.5 mm thickness may be indicated in anterior restorations and pre-molars. Their clinical indication in high-load requirement regions must be carefully evaluated.


Subject(s)
Crowns , Dental Porcelain , Reproducibility of Results , Materials Testing , Ceramics , Zirconium , Dental Stress Analysis , Dental Restoration Failure , Computer-Aided Design
13.
Eur J Oral Sci ; 132(1): e12964, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38062529

ABSTRACT

The aim of this study was to evaluate the effect of two finishing techniques, glazing or polishing, in comparison with the as-cut condition, on the biaxial-flexural-strength (BFS) of a zirconia-reinforced lithium silicate ceramic (ZLS). Cylinders were milled from CAD/CAM blocks and sliced to obtain disc-shaped specimens (ISO6872:2015). Polished and glazed specimens were processed following the manufacturer's instructions. Thirty-three specimens were obtained for each condition and microstructural and BFS/fractographic characterizations were performed. BFS and roughness data were analyzed using Weibull statistics and ANOVA one-way with Tukey post-hoc test, respectively. While a rougher surface was observed for as-cut specimens, smoother surfaces were observed for polished and glazed ZLS at microscopical evaluation and confirmed through surface-roughness evaluation. X-ray spectra depicted a glass phase for all groups and characteristic metasilicate, lithium disilicate, and lithium phosphate peaks for the as-cut and polished specimens. Glazed specimens showed higher characteristic strength than polished and as-cut specimens, which did not differ significantly. While higher Weibull-modulus was observed for the polished than for the as-cut specimens, no statistically significant differences were noted between glazed and polished, and between glazed and as-cut specimens. ZLS presents higher strength when glazed, and polishing increases the structural reliability of the material relative to the as-cut condition. Both finishing techniques reduced surface roughness similarly.


Subject(s)
Ceramics , Lithium , Reproducibility of Results , Materials Testing , Surface Properties , Ceramics/chemistry , Dental Porcelain/chemistry , Zirconium/chemistry , Silicates , Computer-Aided Design
14.
J Esthet Restor Dent ; 36(1): 47-55, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37772362

ABSTRACT

OBJECTIVE: To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate. MATERIAL AND METHODS: Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press). The specimens of each material were divided in two groups according to the hydrofluoric acid concentration: 5% and 10% (n = 15/group), and subdivided according to the etching time: 20, 40 and 60 s (n = 5/group). Crystalline evaluations and chemical composition were performed through x-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS), respectively. Microstructural analyses were performed by scanning electron microscope (SEM), surface roughness (Ra), and material thickness removal evaluation. Thickness removal and Ra data were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: XRD demonstrated characteristic peaks of lithium disilicate crystals, lithium phosphate and of a vitreous phase for all materials. EDS identified different compositions and SEM confirmed different surface responses to acid etching protocols. Material and etching time influenced Ra and material thickness removal (p < 0.05). CONCLUSION: Hydrofluoric acid concentration and etching time affect the surface characteristics of LDS differently. LiSi Press presented higher resistance to hydrofluoric acid etching compared to e.max Press and Rosetta SP. CLINICAL SIGNIFICANCE: Applying the appropriate etching protocol is pivotal to avoid excessive material removal and to prevent jeopardize the mechanical and optical properties of the material.


Subject(s)
Dental Bonding , Hydrofluoric Acid , Hydrofluoric Acid/chemistry , Materials Testing , Dental Porcelain/chemistry , Ceramics/chemistry , Surface Properties , Dental Bonding/methods , Resin Cements/chemistry
15.
J Mech Behav Biomed Mater ; 150: 106311, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38128470

ABSTRACT

This study aimed to develop a recycling process for the remnants of milled 3Y-TZP and enhance their properties using glass infiltration. 3Y-TZP powder was gathered from the vacuum system of CAD-CAM milling equipment, calcined and sieved (x < 75 µm). One hundred twenty discs were fabricated and pre-sintered at 1000 °C/h. These specimens were then divided into four groups, categorized by glass infiltration (non-infiltrated [Zr] or glass-infiltrated [Zr-G]) and sintering temperature (1450 °C [Zr-1450] or 1550 °C [Zr-1550]/2h). After sintering, the specimens were characterized by X-Ray Diffraction (XRD), relative density measurement, and scanning electron microscopy and energy dispersive spectroscopy (SEM-EDS). The biaxial flexural strength test was performed according to the ISO 6872 and followed by fractographic analysis. Subsequent results were analyzed using Weibull statistics. Relative density values of the sintered specimens from Zr-1450 and Zr-1550 groups were 86.7 ± 1.5% and 92.2 ± 1.7%, respectively. Particle size distribution revealed particles within the range of 0.1-100 µm. XRD analysis highlighted the presence of the ZrO2-tetragonal in both the Zr-1450 and Zr-1550 groups. Glass infiltration, however, led to the formation of the ZrO2-monoclinic of 9.84% (Zr-1450-G) and 18.34% (Zr-1550-G). SEM micrographs demonstrated similar microstructural characteristics for Zr-1450 and Zr-1550, whereas the glass-infiltrated groups exhibited comparable infiltration patterns. The highest characteristic strength was observed in the glass-infiltrated groups. Fractographic analyses suggested that fracture origins were related to defects on the tensile side, which propagated to the compression side of the samples. Both the sintering temperature and glass infiltration significantly influenced the mechanical properties of the 3Y-TZP recycled.


Subject(s)
Flexural Strength , Zirconium , Temperature , Materials Testing , Zirconium/chemistry , Yttrium/chemistry , Surface Properties , Dental Materials , Ceramics/chemistry
16.
Materials (Basel) ; 16(24)2023 Dec 07.
Article in English | MEDLINE | ID: mdl-38138684

ABSTRACT

Dental zirconias have been broadly utilized in dentistry due to their high mechanical properties and biocompatibility. Although initially introduced in dentistry as an infrastructure material, the high rate of technical complications related to veneered porcelain has led to significant efforts to improve the optical properties of dental zirconias, allowing for its monolithic indication. Modifications in the composition, processing methods/parameters, and the increase in the yttrium content and cubic phase have been presented as viable options to improve zirconias' translucency. However, concerns regarding the hydrothermal stability of partially stabilized zirconia and the trade-off observed between optical and mechanical properties resulting from the increased cubic content remain issues of concern. While the significant developments in polycrystalline ceramics have led to a wide diversity of zirconia materials with different compositions, properties, and clinical indications, the implementation of strong, esthetic, and sufficiently stable materials for long-span fixed dental prostheses has not been completely achieved. Alternatives, including advanced polycrystalline composites, functionally graded structures, and nanosized zirconia, have been proposed as promising pathways to obtain high-strength, hydrothermally stable biomaterials. Considering the evolution of zirconia ceramics in dentistry, this manuscript aims to present a critical perspective as well as an update to previous classifications of dental restorative ceramics, focusing on polycrystalline ceramics, their properties, indications, and performance.

17.
Biomater Investig Dent ; 10(1): 2268670, 2023.
Article in English | MEDLINE | ID: mdl-38027422

ABSTRACT

To assess the influence of dentifrices with different abrasiveness levels on the properties of dental reconstructive materials. Forty-eight cylinders were obtained from four polymeric materials, being two CAD/CAM acrylic resins (Ivotion-Dent and Ivotion-Base), one injected acrylic resin (IvoBase-Hydrid) and one light-cured resin composite (Empress Direct). Specimens were allocated to four subgroups for toothbrushing simulation according to the dentifrice relative dentin abrasivity (RDA) and silica content: (i) RDA 0 = 0%; (ii) RDA 50 = 3%; (iii) RDA 100 = 10%; and (iv) RDA 120 = 25%. Specimens were then subjected to toothbrushing. Surface analyses [surface roughness Ra (SR) and scanning electron microscopy (SEM)] along with hardness and optical properties [translucency parameter (TP) and contrast ratio (CR)] were evaluated before and after toothbrushing. Statistical analyses were performed using ANOVA and Tukey test. A significant increase in SR was observed after toothbrushing with higher RDA toothpastes for Ivotion-Dent (100 and 120) and IvoBase-Hybrid (120). Ivotion-Base and Empress Direct presented no significant differences in SR when analyzed as a function of timepoint and RDA levels. Hardness was not influenced by toothbrushing with different RDA dentifrices, except for Empress Direct with RDA 0 toothpaste, where a decrease in the hardness was observed. TP of Ivotion-Dent and Empress Direct significantly decreased after toothbrushing with higher RDA dentifrices and CR of Ivotion-Dent, Empress Direct and IvoBase-Hybrid significantly increased with higher RDA dentifrices. The levels of dentifrice abrasiveness affected differently the SR, hardness and optical properties of polymeric reconstructive materials after toothbrushing.

18.
J Mech Behav Biomed Mater ; 148: 106160, 2023 12.
Article in English | MEDLINE | ID: mdl-37832171

ABSTRACT

Zirconia multilayer presents promising prospects, but there is scarce information about its microstructural and mechanical characterization. Therefore, this study sought to produce them in-house and to perform their characterization by comprising four groups of specimens to assess the biaxial flexural strength, microhardness, fracture toughness, phase characterization and quantification, fractography, and microstructural features. Weibull analysis was performed to determine the Weibull modulus and characteristic strength. The results showed that bilayers 3YSZ and 5YSZ presented intermediate mechanical properties when compared to 3YSZ and 5YSZ monolithic controls (680 MPa, 464 MPa, 885 MPa, 594 MPa, respectively). Fractographic analysis revealed that the failure origin was not at the interface in the bilayer groups, but residual stress was present between the layers. Hardness and fracture toughness were not affected by the interface.


Subject(s)
Ceramics , Flexural Strength , Materials Testing , Ceramics/chemistry , Zirconium/chemistry , Yttrium/chemistry , Surface Properties , Dental Materials
19.
J Prosthet Dent ; 130(5): 739.e1-739.e8, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37684141

ABSTRACT

STATEMENT OF PROBLEM: The bonding of implant-supported prostheses is determined by abutment material, convergence angle, height, surface treatment, and luting agents. However, studies evaluating the bonding of luting agents to titanium base abutments with different heights under fatigue conditions are scarce. PURPOSE: The purpose of this in vitro study was to evaluate the retention of zirconia crowns bonded with different luting agents to titanium base abutments of different heights before and after fatigue testing. MATERIAL AND METHODS: Zirconia crowns were designed, milled, and distributed into 4 experimental groups according to the luting agents (G-Multi Primer/G-Cem LinkForce [MP/GC] and Scotchbond Universal/RelyX Ultimate [SU/RU]) and titanium base abutment heights (2.5 mm and 4 mm) (n=10). Pull-out testing was performed in a universal testing machine at a crosshead speed of 1 mm/min until crown displacement. Fatigue testing was performed by an electric precision fatigue simulator (1×106 cycles; 100 N; and 15 Hz), followed by pull-out testing of fatigued specimens. Collected data were statistically evaluated by using a linear mixed model after post hoc comparisons by the least significant difference test (α=.05). RESULTS: Luting agents, abutment heights, and fatigue influenced the bonding retention of zirconia crowns to titanium base abutments. SU/RU agents promoted higher pull-out compared with MP/GC for both abutment heights before and after fatigue. Higher abutment height increased pull-out regarding lower abutment height for SU/RU materials before and after fatigue testing. Although fatigue had no significant effect on the pull-out of MP/GC, lower bond retention was observed for SU/RU after fatigue, regardless of abutment height. CONCLUSIONS: Luting agent composition and the interaction with abutment height and fatigue influenced the retention of zirconia crowns to titanium base abutments.


Subject(s)
Dental Cements , Dental Implants , Dental Cements/chemistry , Titanium/chemistry , Crowns , Zirconium/chemistry , Materials Testing , Dental Abutments , Dental Stress Analysis
20.
Dent Mater ; 39(11): 1022-1031, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37775460

ABSTRACT

OBJECTIVES: To process an alumina-toughened zirconia (ATZ) nanocomposite and to characterize its crystalline phases, microstructure, residual stress, mechanical and optical properties before and after two different artificial aging methodologies. METHODS: Disc-shaped specimens were obtained through uniaxial pressing of a commercial ATZ powder comprised of 80%ZrO2 / 20%Al2O3, with a particle size of 50 nm and 150 nm, respectively. Sintering was performed at 1500ºC for 2 h. Groups were established according to the aging protocol as immediate (ATZ-I) and aged either in autoclave (ATZ-A) or hydrothermal reactor (ATZ-R) at 134 ºC for 20 h at 2.2 bar. Crystalline phases and microstructure were assessed by X-ray diffraction (XRD) and scanning electron microscopy (SEM), respectively. Residual stress was evaluated by Raman spectroscopy. Contrast Ratio (CR) and Translucency Parameter (TP) were calculated to characterize optical properties. Mechanical properties were analyzed through Vickers microhardness, fracture toughness, and biaxial flexural strength test. RESULTS: XRD spectra of both aging protocols revealed the presence of monoclinic zirconia (20-31%), where higher phase transformation was observed after aging in hydrothermal reactor. Optical properties evaluation demonstrated high opacity (CR: 0.99) and masking ability (TP: 0.26), with no significant differences after aging. Raman spectroscopy evidenced the presence of residual compressive stresses in the aged groups, being significantly higher for ATZ-R (-215.2 MPa). As-sintered specimens revealed hardness of ∼12.3 GPa and fracture toughness of ∼1.9 MPa.m1/2. Characteristic strength was 740 MPa for ATZ-I, 804 MPa for ATZ-A, and 879 MPa for ATZ-R, with significant differences between groups. Weibull modulus ranged from 16.5 to 18.8. All groups demonstrated high reliability up to 500 MPa stress missions (99-100%), with no significant differences after aging. SIGNIFICANCE: The experimental ATZ nanocomposite presented high opacity and a high Weibull modulus. While aging created internal compressive stress responsible for an increase in characteristic strength, the nanocomposite was susceptible to hydrothermal degradation. Further studies are required to evaluate its degradation kinetics at low temperatures.