Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Chromatogr ; 27(11): 1457-62, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23813413

ABSTRACT

A new method was developed for the quantitation of 3-α-hydroxy tibolone, in human plasma, after oral administration of a tablet formulation containing tibolone (2.5 mg). 3-α-Hydroxy tibolone was extracted by a liquid-liquid procedure, using cyproterone acetate as internal standard and chlorobutane as extraction solvent. After extraction, samples were submitted to a derivatization step with p-toluenesulfonyl isocyanate. A mobile phase consisting of acetonitrile and water (72:28 v/v) was used and chromatographic separation was achieved using Agilent XDB C18 column (100 × 4.6 mm i.d.; 5 µm particle size), at 40°C. Mass spectrometric detection was performed using atmospheric pressure chemical ionization in negative mode for 3-α-hydroxy tibolone and in positive mode for cyproterone acetate. The fragmentation transitions were m/z 510.2 → m/z 170.1 and m/z 417.0 → m/z 357.1 for 3-α-hydroxy tibolone and cyproterone acetate, respectively. Calibration curves were constructed over the range 100-30,000 pg/mL and the method was shown to be specific, precise and accurate, with a mean recovery rate of 94.2% for 3-α-hydroxy tibolone. No matrix effect or carry-over was detected in the samples. The validated method was applied in a pharmacokinetic study with a tibolone formulation in healthy female volunteers.


Subject(s)
Chromatography, Liquid/methods , Norpregnenes/blood , Tandem Mass Spectrometry/methods , Administration, Oral , Estrogen Receptor Modulators/administration & dosage , Female , Humans , Limit of Detection , Norpregnenes/administration & dosage
2.
J Pharm Biomed Anal ; 61: 38-43, 2012 Mar 05.
Article in English | MEDLINE | ID: mdl-22178434

ABSTRACT

A sensitive method for the determination of fluticasone in plasma was developed using high performance liquid chromatography with tandem mass spectrometric detection, whereas beclomethasone was used as internal standard. The analytes were extracted with a simple liquid-liquid extraction from the plasma samples and separated on an ACE C(18) 50 × 4.6 mm i.d.; 5 µm particle size column with a mobile phase consisting of acetonitrile - 0.01% formic acid (48:52, v/v) at a flow rate of 1 ml/min. Detection was achieved by an Applied Biosystems API 5000 mass spectrometer (LC-MS/MS) set at unit resolution in the multiple reaction monitoring mode. Atmospheric pressure chemical ionization (APCI) was used for ion production. The mean recovery for fluticasone propionate was 85%, with a lower limit of quantification set at 2 pg/mL. The validated analytical method was applied to a bioequivalence study of fluticasone propionate administered by nasal spray formulations in human volunteers.


Subject(s)
Androstadienes/blood , Atmospheric Pressure , Mass Spectrometry/methods , Nasal Sprays , Adult , Androstadienes/chemistry , Chemistry, Pharmaceutical , Chromatography, High Pressure Liquid/methods , Chromatography, High Pressure Liquid/standards , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Cross-Over Studies , Female , Fluticasone , Humans , Male , Mass Spectrometry/standards , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Therapeutic Equivalency , Time Factors
3.
Biomed Chromatogr ; 26(7): 851-6, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22031460

ABSTRACT

A rapid method for the quantification of glucosamine in human plasma using high-performance liquid chromatography coupled to tandem mass spectrometry was developed and validated. The sample preparation includes a simple deproteinization step, using D-[1-¹³C] glucosamine hydrochloride as an internal standard. Chromatographic separation was performed on an ACE Ciano column using isocratic elution with acetonitrile and aqueous 2 mM ammonium acetate containing 0.025% formic acid (80:20). Selected reaction monitoring was performed using the transitions m/z 180.1 → m/z 72.1 and m/z 181.0 → m/z 74.6 to quantify glucosamine and internal standard, respectively. The method was validated and proved to be linear, accurate and precise over the range 50-5000 ng/mL of glucosamine. Recovery rates higher than 90% were obtained for both glucosamine and internal standard. No matrix effect was detected in the samples. The validated method was successfully applied to a pharmacokinetic study after oral administration of a powder for oral solution formulation containing glucosamine sulfate.


Subject(s)
Chromatography, High Pressure Liquid/methods , Glucosamine/blood , Tandem Mass Spectrometry/methods , Administration, Oral , Female , Glucosamine/administration & dosage , Glucosamine/pharmacokinetics , Humans , Male , Powders/administration & dosage , Reproducibility of Results , Sensitivity and Specificity
4.
J Mass Spectrom ; 46(9): 943-8, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21915959

ABSTRACT

A sensitive and fast high-performance liquid chromatography-electrospray ionization-MS/MS method for the simultaneous quantitation of levodopa and carbidopa in human plasma was developed and validated. A simple protein precipitation step with perchloric acid was used for the cleanup of plasma, and methyldopa was added as an internal standard. The analyses were carried out using an ACE C(18) column (50 × 4.6 mm i.d.; 5 µm particle size) and a mobile phase consisting of 0.2% formic acid and acetonitrile (90:10). The triple-quadrupole mass spectrometer equipped with an electrospray source in positive mode was set up in the selective reaction monitoring mode to detect the ion transitions m/z 198.1 → m/z 107.0, m/z 227.2 → m/z 181.0, and m/z 212.1 → m/z 139.2 for levodopa, carbidopa, and methyldopa, respectively. The method was validated and proved to be linear, accurate, and precise over the range 50-5000 ng/mL for levodopa and 3-600 ng/mL for carbidopa. The proposed method was successfully applied in a pharmacokinetic study with a levodopa/carbidopa tablet formulation in healthy volunteers.


Subject(s)
Carbidopa/blood , Chromatography, High Pressure Liquid/methods , Levodopa/blood , Tandem Mass Spectrometry/methods , Administration, Oral , Carbidopa/administration & dosage , Carbidopa/pharmacokinetics , Drug Stability , Female , Humans , Levodopa/administration & dosage , Levodopa/pharmacokinetics , Male , Methyldopa/blood , Methyldopa/pharmacokinetics , Reproducibility of Results , Sensitivity and Specificity , Tablets/administration & dosage , Tablets/pharmacokinetics
5.
J Pharm Biomed Anal ; 56(5): 1094-100, 2011 Dec 15.
Article in English | MEDLINE | ID: mdl-21856105

ABSTRACT

A sensitive and simple method was developed for the quantitation of levodopa and its metabolite 3-O-methyldopa, in human plasma, after oral administration of tablet formulations containing levodopa (200 mg) and benserazide (50 mg). The analytes were extracted by a protein precipitation procedure, using carbidopa as an internal standard. A mobile phase consisting of 0.2% formic acid and acetonitrile (94:6, v/v) was used and chromatographic separation was achieved using ACE C(18) column (50 mm×4.6 mm i.d.; 5 µm particle size). Selected reaction monitoring was performed using the fragmentation transitions m/z 198→m/z 107, m/z 212→m/z 166 and m/z 227→m/z 181 for levodopa, 3-O-methyldopa and carbidopa, respectively. Calibration curves were constructed over the range 50.0-6000.0 ng/mL for levodopa and 25.0-4000.0 ng/mL for 3-O-methyldopa. The method shown to be specific, precise, accurate and provided recovery rates higher than 85% for all analytes. No matrix effect was detected in the samples. The validated method was applied in a pharmacokinetic study with a levodopa/benserazide tablet formulation in healthy volunteers.


Subject(s)
Benserazide/blood , Chromatography, High Pressure Liquid/methods , Levodopa/blood , Methyldopa/blood , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Benserazide/pharmacokinetics , Calibration , Humans , Levodopa/pharmacokinetics , Methyldopa/pharmacokinetics , Quality Control , Reproducibility of Results , Tablets
SELECTION OF CITATIONS
SEARCH DETAIL
...