Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Faraday Discuss ; 183: 233-48, 2015.
Article in English | MEDLINE | ID: mdl-26388308

ABSTRACT

The strong non-equilibrium conditions provided by the plasma phase offer the opportunity to beat traditional thermal process energy efficiencies via preferential excitation of molecular vibrations. Simple molecular physics considerations are presented to explain potential dissociation pathways in plasma and their effect on energy efficiency. A common microwave reactor approach is evaluated experimentally with Rayleigh scattering and Fourier transform infrared spectroscopy to assess gas temperatures (exceeding 10(4) K) and conversion degrees (up to 30%), respectively. The results are interpreted on a basis of estimates of the plasma dynamics obtained with electron energy distribution functions calculated with a Boltzmann solver. It indicates that the intrinsic electron energies are higher than is favorable for preferential vibrational excitation due to dissociative excitation, which causes thermodynamic equilibrium chemistry to dominate. The highest observed energy efficiencies of 45% indicate that non-equilibrium dynamics had been at play. A novel approach involving additives of low ionization potential to tailor the electron energies to the vibrational excitation regime is proposed.

2.
Rev Sci Instrum ; 83(11): 113508, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23206063

ABSTRACT

Strong scattering of high-power millimeter waves at 140 GHz has been shown to take place in heating and current-drive experiments at TEXTOR when a tearing mode is present in the plasma. The scattering signal is at present supposed to be generated by the parametric decay instability. Here we describe the heterodyne detection system used to characterize the newly discovered signal measured at TEXTOR, and we present spectral shapes in which the signal can appear under different conditions. The radiation is collected by the receiver through a quasi-optical transmission line that is independent of the electron cyclotron resonance heating transmission line, and so the scattering geometry is variable. The signal is detected with 42 frequency channels ranging from 136 to 142 GHz. We demonstrate that the large signal does not originate from gyrotron spurious radiation. The measured signal agrees well with independent backscattering radiometer data.

3.
Rev Sci Instrum ; 82(6): 063508, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21721692

ABSTRACT

An intermediate frequency (IF) band digitizing radiometer system in the 100-200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the full wave information of the mm-wave signals under investigation. The system is based on directly digitizing the IF band after down conversion. The enabling technology consists of a fast multi-giga sample analog to digital converter that has recently become available. Field programmable gate arrays (FPGA) are implemented to accomplish versatile real-time data analysis. A prototype system has been developed and tested and its performance has been compared with conventional electron cyclotron emission (ECE) spectrometer systems. On the TEXTOR Tokamak a proof of principle shows that ECE, together with high power injected and scattered radiation, becomes amenable to measurement by this device. In particular, its capability to measure the phase of coherent signals in the spectrum offers important advantages in diagnostics and control. One case developed in detail employs the FPGA in real-time fast Fourier transform (FFT) and additional signal processing. The major benefit of such a FFT-based system is the real-time trade-off that can be made between frequency and time resolution. For ECE diagnostics this corresponds to a flexible spatial resolution in the plasma, with potential application in smart sensing of plasma instabilities such as the neoclassical tearing mode (NTM) and sawtooth instabilities. The flexible resolution would allow for the measurement of the full mode content of plasma instabilities contained within the system bandwidth.

4.
Rev Sci Instrum ; 80(10): 103504, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19895061

ABSTRACT

A fast Fourier transform (FFT) based wide range millimeter wave diagnostics for spectral characterization of scattered millimeter waves in plasmas has been successfully brought into operation. The scattered millimeter waves are heterodyne downconverted and directly digitized using a fast analog-digital converter and a compact peripheral component interconnect computer. Frequency spectra are obtained by FFT in the time domain of the intermediate frequency signal. The scattered millimeter waves are generated during high power electron cyclotron resonance heating experiments on the TEXTOR tokamak and demonstrate the performance of the diagnostics and, in particular, the usability of direct digitizing and Fourier transformation of millimeter wave signals. The diagnostics is able to acquire 4 GHz wide spectra of signals in the range of 136-140 GHz. The rate of spectra is tunable and has been tested between 200,000 spectra/s with a frequency resolution of 100 MHz and 120 spectra/s with a frequency resolution of 25 kHz. The respective dynamic ranges are 52 and 88 dB. Major benefits of the new diagnostics are a tunable time and frequency resolution due to postdetection, near-real time processing of the acquired data. This diagnostics has a wider application in astrophysics, earth observation, plasma physics, and molecular spectroscopy for the detection and analysis of millimeter wave radiation, providing high-resolution spectra at high temporal resolution and large dynamic range.

5.
Phys Rev Lett ; 103(12): 125001, 2009 Sep 18.
Article in English | MEDLINE | ID: mdl-19792443

ABSTRACT

In tokamak plasmas with a tearing mode, strong scattering of high power millimeter waves, as used for heating and noninductive current drive, is shown to occur. This new wave scattering phenomenon is shown to be related to the passage of the O point of a magnetic island through the high power heating beam. The density determines the detailed phasing of the scattered radiation relative to the O-point passage. The scattering power depends strongly nonlinearly on the heating beam power.

6.
Rev Sci Instrum ; 79(9): 093503, 2008 Sep.
Article in English | MEDLINE | ID: mdl-19044409

ABSTRACT

An electron cyclotron emission (ECE) receiver inside the electron cyclotron resonance heating (ECRH) transmission line has been brought into operation. The ECE is extracted by placing a quartz plate acting as a Fabry-Perot interferometer under an angle inside the electron cyclotron wave (ECW) beam. ECE measurements are obtained during high power ECRH operation. This demonstrates the successful operation of the diagnostic and, in particular, a sufficient suppression of the gyrotron component preventing it from interfering with ECE measurements. When integrated into a feedback system for the control of plasma instabilities this line-of-sight ECE diagnostic removes the need to localize the instabilities in absolute coordinates.

7.
Phys Rev Lett ; 89(21): 214801, 2002 Nov 18.
Article in English | MEDLINE | ID: mdl-12443417

ABSTRACT

The Fusion Free-Electron Maser (FFF) is the prototype of a high-power, tunable source of mm-wave radiation, for use on fusion plasma devices. In previous experiments a net output power of 730 kW at 206 GHz was generated in short pulses. The present experiment has been equipped with a system to recover the charge and energy of the spent electron beam. We present experimental results which show output of mm-wave radiation at constant power level during the full pulse length, as well as single-frequency operation; even though the cavity is highly overmoded; the latter is reached by effective suppression of spurious modes by the feedback system.

8.
Article in English | MEDLINE | ID: mdl-11969591

ABSTRACT

A high-power, frequency-tunable electrostatic free-electron maser, being developed at the FOM Institute for Plasma Physics "Rijnhuizen," shows lasing at various frequencies. An output power of 730 kW at 206 GHz is generated by a 7.2-A, 1.77-MeV electron beam, and 380 kW at 165 GHz is generated by a 7.4-A, 1.65-MeV electron beam. In the present experimental setup, without recovery of the spent electron beam power, the pulse length is limited to 12 micros. Nevertheless, the main issues, such as the possibility of high-power, single-mode operation and frequency tuning, have been confirmed. The experimental results and the dynamics of the laser process are well in accordance with simulations.

SELECTION OF CITATIONS
SEARCH DETAIL
...