Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Lancet Infect Dis ; 13(9): 745-51, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23782859

ABSTRACT

BACKGROUND: The Middle East respiratory syndrome coronavirus (MERS-CoV) is an emerging virus involved in cases and case clusters of severe acute respiratory infection in the Arabian Peninsula, Tunisia, Morocco, France, Italy, Germany, and the UK. We provide a full description of a fatal case of MERS-CoV infection and associated phylogenetic analyses. METHODS: We report data for a patient who was admitted to the Klinikum Schwabing (Munich, Germany) for severe acute respiratory infection. We did diagnostic RT-PCR and indirect immunofluorescence. From time of diagnosis, respiratory, faecal, and urine samples were obtained for virus quantification. We constructed a maximum likelihood tree of the five available complete MERS-CoV genomes. FINDINGS: A 73-year-old man from Abu Dhabi, United Arab Emirates, was transferred to Klinikum Schwabing on March 19, 2013, on day 11 of illness. He had been diagnosed with multiple myeloma in 2008, and had received several lines of treatment. The patient died on day 18, due to septic shock. MERS-CoV was detected in two samples of bronchoalveolar fluid. Viral loads were highest in samples from the lower respiratory tract (up to 1·2 × 10(6) copies per mL). Maximum virus concentration in urine samples was 2691 RNA copies per mL on day 13; the virus was not present in the urine after renal failure on day 14. Stool samples obtained on days 12 and 16 contained the virus, with up to 1031 RNA copies per g (close to the lowest detection limit of the assay). One of two oronasal swabs obtained on day 16 were positive, but yielded little viral RNA (5370 copies per mL). No virus was detected in blood. The full virus genome was combined with four other available full genome sequences in a maximum likelihood phylogeny, correlating branch lengths with dates of isolation. The time of the common ancestor was halfway through 2011. Addition of novel genome data from an unlinked case treated 6 months previously in Essen, Germany, showed a clustering of viruses derived from Qatar and the United Arab Emirates. INTERPRETATION: We have provided the first complete viral load profile in a case of MERS-CoV infection. MERS-CoV might have shedding patterns that are different from those of severe acute respiratory syndrome and so might need alternative diagnostic approaches. FUNDING: European Union; German Centre for Infection Research; German Research Council; and German Ministry for Education and Research.


Subject(s)
Coronavirus Infections/diagnosis , Coronavirus/isolation & purification , Genome, Viral , RNA, Viral/urine , Aged , Anti-Infective Agents/administration & dosage , Antiviral Agents/administration & dosage , Coronavirus/classification , Coronavirus/genetics , Coronavirus Infections/drug therapy , Fatal Outcome , Feces/virology , Germany , Humans , Male , Phylogeny , Shock, Septic , United Arab Emirates , Viral Load
2.
Chest ; 143(3): 678-686, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23460154

ABSTRACT

BACKGROUND: Hypercapnic respiratory failure in patients with COPD frequently requires mechanical ventilatory support. Extracorporeal CO2 removal (ECCO2R) techniques have not been systematically evaluated in these patients. METHODS: This is a pilot study of a novel ECCO2R device that utilizes a single venous catheter with high CO2 removal rates at low blood flows. Twenty hypercapnic patients with COPD received ECCO2R. Group 1 (n = 7) consisted of patients receiving noninvasive ventilation with a high likelihood of requiring invasive ventilation, group 2 (n = 2) consisted of patients who could not be weaned from noninvasive ventilation, and group 3 (n = 11) consisted of patients on invasive ventilation who had failed attempts to wean. RESULTS: The device was well tolerated, with complications and rates similar to those seen with central venous catheterization. Blood flow through the system was 430.5 ± 73.7 mL/min, and ECCO2R was 82.5 ± 15.6 mL/min and did not change significantly with time. Invasive ventilation was avoided in all patients in group 1 and both patients in group 2 were weaned; PaCO2 decreased significantly (P < .003) with application of the device from 78.9 ± 16.8 mm Hg to 65.9 ± 11.5 mm Hg. In group 3, three patients were weaned, while the level of invasive ventilatory support was reduced in three patients. One patient in group 3 died due to a retroperitoneal bleed following catheterization. CONCLUSIONS: This single-catheter, low-flow ECCO2R system provided clinically useful levels of CO2 removal in these patients with COPD. The system appears to be a potentially valuable additional modality for the treatment of hypercapnic respiratory failure.


Subject(s)
Hypercapnia/therapy , Noninvasive Ventilation/methods , Pulmonary Disease, Chronic Obstructive/complications , Respiratory Insufficiency/therapy , Aged , Equipment Design , Extracorporeal Membrane Oxygenation , Feasibility Studies , Female , Humans , Hypercapnia/complications , Hypercapnia/mortality , Male , Middle Aged , Noninvasive Ventilation/instrumentation , Pain Measurement , Pilot Projects , Respiratory Insufficiency/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...