Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 58(3): 555-68, 2013 Feb 07.
Article in English | MEDLINE | ID: mdl-23318277

ABSTRACT

A well-established navigation method is one of the key conditions for successful brain surgery: it should be accurate, safe and online operable. Recent research shows that optical coherence tomography (OCT) is a potential solution for this application by providing a high resolution and small probe dimension. In this study a fiber-based spectral-domain OCT system utilizing a super-luminescent-diode with the center wavelength of 840 nm providing 14.5 µm axial resolution was used. A composite 125 µm diameter detecting probe with a gradient index (GRIN) fiber fused to a single mode fiber was employed. Signals were reconstructed into grayscale images by horizontally aligning A-scans from the same trajectory with different depths. The reconstructed images can display brain morphology along the entire trajectory. For scans of typical white matter, the signals showed a higher reflection of light intensity with lower penetration depth as well as a steeper attenuation rate compared to the scans typical for gray matter. Micro-structures such as axon bundles (70 µm) in the caudate nucleus are visible in the reconstructed images. This study explores the potential of OCT to be a navigation modality in brain surgery.


Subject(s)
Brain/cytology , Optical Fibers , Tomography, Optical Coherence/instrumentation , Animals , Brain/physiology , Brain/surgery , Electrophysiological Phenomena , Image Processing, Computer-Assisted , Lenses , Rats , Surgery, Computer-Assisted
2.
Opt Express ; 20(6): 6761-76, 2012 Mar 12.
Article in English | MEDLINE | ID: mdl-22418560

ABSTRACT

Swept-source optical coherence tomography (SS-OCT) is sensitive to sample motion during the wavelength sweep, which leads to image blurring and image artifacts. In line-field and full-field SS-OCT parallelization is achieved by using a line or area detector, respectively. Thus, approximately 1000 lines or images at different wavenumbers are acquired. The sweep duration is identically with the acquisition time of a complete B-scan or volume, rendering parallel SS-OCT more sensitive to motion artifacts than scanning OCT. The effect of axial motion on the measured spectra is similar to the effect of non-balanced group velocity dispersion (GVD) in the interferometer arms. It causes the apparent optical path lengths in the sample arm to vary with the wavenumber. Here we propose the cross-correlation of sub-bandwidth reconstructions (CCSBR) as a new algorithm that is capable of detecting and correcting the artifacts induced by axial motion in line-field or full-field SS-OCT as well as GVD mismatch in any Fourier-domain OCT (FD-OCT) setup. By cross-correlating images which were reconstructed from a limited spectral range of the interference signal, a phase error is determined which is used to correct the spectral modulation prior to the calculation of the A-scans. Performance of the algorithm is demonstrated on in vivo full-field SS-OCT images of skin and scanning FD-OCT of skin and retina.


Subject(s)
Algorithms , Artifacts , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Tomography, Optical Coherence/methods , Fourier Analysis , Motion , Reproducibility of Results , Sensitivity and Specificity
3.
Opt Lett ; 36(13): 2390-2, 2011 Jul 01.
Article in English | MEDLINE | ID: mdl-21725421

ABSTRACT

Scanning optical coherence tomography (OCT) is limited in sensitivity and resolution by the restricted focal depth of the confocal detection scheme. Holoscopy, a combination of holography and Fourier-domain full-field OCT, is proposed as a way to detect photons from all depths of a sample volume simultaneously with uniform sensitivity and lateral resolution, even at high NAs. By using the scalar diffraction theory, as frequently applied in digital holographic imaging, we fully reconstruct the object field with depth-invariant imaging quality. In vivo imaging of human skin is demonstrated with an image quality comparable to conventionally scanned OCT.


Subject(s)
Holography/methods , Tomography, Optical Coherence/methods , Fingers , Fourier Analysis , Humans , Photons
4.
Opt Lett ; 35(20): 3432-4, 2010 Oct 15.
Article in English | MEDLINE | ID: mdl-20967090

ABSTRACT

In vivo full-field (FF) optical coherence tomography (OCT) images of human retina are presented by using a rapidly tunable laser source in combination with an ultra-high-speed camera. Fourier-domain FF-OCT provided a way to increase the speed of retinal imaging by parallel acquisition of A-scans. Reduced contrast caused by cross talk was observed only below the retinal pigment epithelium. With a 100Hz sweep rate, FF-OCT was fast enough to acquire OCT images with acceptable motion artifacts. FF-OCT allows ultrafast retinal imaging, boosting image speed by a lack of moving parts and a considerably higher irradiation power.


Subject(s)
Retina/cytology , Tomography, Optical Coherence/methods , Humans , Imaging, Three-Dimensional/methods , Lasers
SELECTION OF CITATIONS
SEARCH DETAIL
...