Results 1 - 9 de 9
Filter
1.
Eur J Hosp Pharm ; 30(3): 160-166, 2023 05.
Article in English | MEDLINE | ID: mdl-34233906

ABSTRACT

OBJECTIVES: To describe the application of the model described in part A and part B of this series of articles for risk assessment (RA) and risk control (RC) of non-sterility during aseptic handling. The model was applied in nine hospital pharmacies. METHODS: The starting point was an audit of each hospital pharmacy. The determined risk reduction and remaining risks were entered into a risk assessment model. The corresponding risk prioritisation numbers (RPNs) for each source of risk were calculated and these values were summed up to a cumulative RPN. Subsequently, all hospital pharmacies started an improvement programme, using the risk assessment as input. Results of aseptic process simulation (APS) and microbiological monitoring (MM) were also collected. The participants were informed about their progress of risk reduction and results of APS and MM during the study period. At the end of the study (about 4 years after the start), a final assessment was executed by using a checklist with risk reducing measures for each source of risk. Additional risk reduction and remaining risks were put in an RA and RC template and corresponding RPN values and a new cumulative RPN were determined. RESULTS: At the start of the study differences in cumulative RPN values were relatively small (from 630 to 825). At the end they were relatively great (from 230 to 725), which illustrates a different sense of urgency for reducing the risk of non-sterility. Of all the risk reducing measures, a yearly audit of all operators had the greatest impact on reducing the risk of non-sterility. Except for glove prints, there was no correlation between process improvement (lower cumulative RPN) and results of microbiological controls. CONCLUSION: A systematic and science-based reduction of the risks of non-sterility can be done by using a checklist with risk reducing measures and an RA & RC template. Prospectively, the relevance of each risk reducing measure can be demonstrated by RPN calculations. Microbiological controls are an important part of the overall assurance of product quality. However, the results are less useful for assessing the risk of non-sterility.


Subject(s)
Pharmacies , Humans , Risk Assessment/methods , Hospitals
2.
Eur J Pharm Sci ; 175: 106228, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-35640785

ABSTRACT

INTRODUCTION: 'Aseptic handling is the procedure to enable sterile products to be made ready to administer using closed systems' (EU Resolution CM/Res(2016)2). Microbiological controls are an important part of the overall assurance of process and product quality of aseptic handling. They consist of the End-of-Session Broth Test (ESBT) using Tryptone Soya Broth, Microbiological Monitoring (MM) using Ø 55- and 90-mm agar plates and a periodical Operator Broth Transfer Validation Test (OBTVT) using Tryptone Soya Broth. This study describes the results of these controls over a 7-year period, involving between 44 and 49 pharmacies (mostly hospital pharmacies). All pharmacies use a web-based programme for processing, evaluation and assessing microbiological controls ('Microbio'). Aggregated results in Microbio are used for benchmarking and feedback information. OBJECTIVE: The objective of this study is to analyse the results of the 7-year period and to develop methods for assessing of, and determining realistic limits for, microbiological controls during aseptic handling. As secondary objective the role of Microbio is highlighted. RESULTS AND DISCUSSION: Results of ESBT are expressed as Contamination Rate (CR), which is the percentage of units filled in a process simulation that are positive for microbial growth after incubation. Compared with the first 3 years of the study, the results in the last 4 years were significantly better: mean CRs are 0.20 and 0.11, respectively (p-value <0.01). For assessing CRs of ESBT, the approach 'the more frequent samples with growth, the stronger the corrective actions' was adopted. Levels of investigative and corrective actions, based on the 95% Upper Confidence Limit, are suggested. Microbiological Monitoring (MM) during aseptic handling into a laminar airflow cabinet or safety cabinet consists of settle plates, glove prints, contact plates of the worktop and surface bioburden determination of disinfected ampoules and vials. The results are expressed as the Contamination Recovery Rate (CRR), which is the rate at which MM samples contain any level of contamination. During the study period, the results of glove prints and contact plates improved substantially. The most probable explanation of this finding is improved disinfection procedures of the gloved hands, the worktop inside LAF/SC and the ampoules and vials. Results of settle plates did not change. There were too few results available to evaluate the surface bioburden of disinfected ampoules and vials. Benchmarking and feedback information from Microbio may have contributed to the improved ESBT and MM results. Results of the Operator Broth Transfer Validation Test (OBTVT) are expressed as Contamination Rate (CR). The target is zero samples with growth (CR = 0). The overall CR result over the study period is 0.50%. This is worse than ESBT (overall CR is 0.14%). This is probably due to the high number of critical steps in OBTVT compared to ESBT. CONCLUSION: Results of microbiological controls improved during the study period. Realistic limits as well as methods for assessing ESBT and MM results are given and discussed.


Subject(s)
Pharmacies , Drug Contamination/prevention & control , Hospitals
3.
Eur J Hosp Pharm ; 29(3): 151-156, 2022 05.
Article in English | MEDLINE | ID: mdl-32385070

ABSTRACT

OBJECTIVES: To determine prospectively the sources of risk of non-sterility during aseptic handling and to quantify the risks of each of these sources. METHODS: A risk assessment (RA) of non-sterility according to Failure Mode and Effect Analysis was executed by a multidisciplinary team of (hospital) pharmacists and technicians, a consultant experienced in aseptic processing and an independent facilitator. The team determined the sources of risk of non-sterility, a 5 point scale for severity, occurrence and detection, and risk acceptance levels. Input about general applied risk reduction was collected by audits in 10 hospital pharmacies. The results of these audits were used for determining the remaining risks. The results, as well as scientific information and the experience of the team members, was used to determine scores for severity, occurrence and detection. RESULTS: Multiplying the scores for severity, occurrence and detection results in the risk prioritisation number (RPN) which is a relative value of the remaining risks of non-sterility for each source. Incorrect disinfection techniques of non-sterile materials and the chances of touching critical spots were estimated as the greatest risks. The risk of non-sterility via the airborne route was low. RPN values were helpful in prioritising measures for additional risk reduction (this will be described in an accompanying article). CONCLUSION: The RA, described here, was a systematic survey related to all sources of risk of non-sterility during aseptic handling. The determined RPN values were helpful in prioritising measures for additional risk reduction.


Subject(s)
Pharmacies , Hospitals , Humans , Pharmacists , Risk Assessment
4.
Eur J Hosp Pharm ; 29(1): 12-17, 2022 01.
Article in English | MEDLINE | ID: mdl-34930789

ABSTRACT

OBJECTIVES: To transfer sterile medical devices (SMD), infusion bags (IB), ampoules (A), injection vials (V) and infusion bottles (B) into a laminar airflow cabinet (LAF) or safety cabinet (SC) with a surface bioburden as low as possible. METHODS: Surface bioburden of the outer layer of SMD, IB, A, V and B was determined by contact plates. Surface bioburden determination of critical spots on A, V and B (ampoule necks and stoppers) was determined by high-recovery swabs and contact plates. Particle emission from white cardboard boxes was determined by a particle counter. RESULTS: The chances of a contaminated outer layer of SMD is negligible as long as they stay in their original boxes. The outer layer of double-packed IB can contain a considerable number of micro-organisms. As found in previous studies, the surface bioburden of A, V and B is low as long as they stay in their original cardboard boxes. Particle emission from white boxes is low. The necessity of a final disinfection step inside LAF/SC of critical sspots of A, V and B cannot be proven. SmallSMD, ampoules and injection vials can be transferred into the background areain their original white boxes. Other materials have to be unpacked in front ofthe lock while the operator wear disposable gloves. Disinfection of the outerlayer of IB, before transfer trough the lock, is advised. Tohave materials with a low chance of contamination in LAF/SC, transfer bypresentation for SMD and IB and using a sterile tray for disinfected materialsis an effective procedure. Wiping of ampoule necks and stoppers inside LAF/SC isadvised based on risk assessment.Small SMD, ampoules and injection vials can be transferred into the background areain their original white boxes. Other materials have to be unpacked in front ofthe lock while the operator wear disposable gloves. Disinfection of the outerlayer of IB, before transfer trough the lock, is advised. CONCLUSION: When SMD, ampoules, injection vials and infusion bottles stay in their original boxes as long as possible, the aseptic transfer and the disinfection procedure can be maintained effectively and efficiently.


Subject(s)
Pharmacies , Disinfection/methods , Drug Contamination/prevention & control , Hospitals
5.
Eur J Hosp Pharm ; 28(5): 271-275, 2021 09.
Article in English | MEDLINE | ID: mdl-34426480

ABSTRACT

OBJECTIVES: To improve the disinfection methods for materials with a non-sterile surface to be used in aseptic handling. METHODS: The surface bioburden on ampoules (A) and injection vials (IV) is determined by contact plates and total immersion. The occurrence of spore-forming bacteria is determined by strain colouring and matrix-assisted laser desorption ionisation-time of flight mass spectrometry. The disinfection procedures of non-sterile materials in 10 hospital pharmacies are judged by observing. RESULTS: After wiping according to local disinfection methods, the mean surface bioburden determined by contact plates in 10 hospital pharmacies is 0.36 (plastic A), 0.50 (glass A) and 0.29 colony-forming unit (cfu) (IV). The observers found great differences in accuracy of wiping and degree of wetting the sterile gauzes.After improved wiping with commercially available alcohol impregnated sterile wipes and a two-towel technique (one-step TT disinfection), the mean surface bioburden determined by contact plates is 0.03 (plastic A), 0.2 (glass A) and 0.13 cfu (IV). Further improvement can be reached by submerging A and IV in ethanol 70% followed by improved wiping (two-step TT disinfection), but still micro-organisms will remain (mean surface bioburden determined by total immersion is 0 (plastic A) and 0.3 cfu (IV); glass A not determined). Two-step TT disinfection is more labour intensive. Spilling of alcohol is another disadvantage. However, we presume one-step TT disinfection is effective enough in daily practice. Routine surface bioburden determinations have to prove this.The effectiveness of the combination of spray and wipe is not examined because we observed a quick disappearance of alcohols from vertical as well as horizontal surfaces, which shortens the contact time to far below the advised 2 min.Spore-forming bacteria disappear as quickly as other micro-organisms during disinfection by alcohols. CONCLUSION: Local disinfection procedures can be improved. Complete removal of micro-organisms from materials with a non-sterile surface, even after two-step TT disinfection, is impossible. Routine surface bioburden determinations have to prove if one-step TT disinfection is effective enough.


Subject(s)
Disinfection , Pharmacies , Disinfection/methods , Hospitals
6.
Eur J Hosp Pharm ; 28(1): 38-41, 2021 01.
Article in English | MEDLINE | ID: mdl-33355282

ABSTRACT

OBJECTIVES: To develop methods for surface bioburden determination of ampoules and vials to be used in the validation of the disinfection procedures and in routine monitoring of ampoules and vials. METHODS: The surface bioburdens of ampoules and vials are determined before and after disinfection by contact plates and total immersion. RESULTS: The mean surface bioburdens of non-disinfected ampoules and vials taken straight from the original boxes are 2.4 and 5.01 cfu (total immersion; n = 20), and 0.97 and 0.94 cfu (contact plates; n = 60). The mean surface bioburdens of ampules and vials after disinfection by wiping are 1.15 and 7.50 cfu (total immersion; n = 20), and 0.12 and 0.10 cfu (contact plates; n = 60). The high number of cfu on vials (total immersion) indicate hidden cfu around the neck not removable by wiping and not detected by contact plates. Total immersion needs special laboratory facilities and is expensive (about €50 a sample). Therefore, it is less appropriate for use in routine monitoring. However, because of the high recovery, it is the method of choice for the validation of the disinfection procedure. Surface bioburden determination by contact plates is relatively simple. Non-flat surfaces cannot be reached, but the recovery from the touched flat part of the surface is high (around 50%). The recovery from swabs is low (around 10%). Another disadvantage of swabs is the laboratory work after sampling. We therefore advise contact plates for routine monitoring. To get a reliable value of the mean surface bioburden at least 30 samples need to be examined. CONCLUSION: Total immersion is the method of choice for the determination of the effectiveness of a disinfection procedure for ampoules and vials. Contact plate is the method of choice for routine monitoring of the surfaces of ampoules and vials.


Subject(s)
Pharmacies , Disinfection/methods , Hospitals
7.
Eur J Hosp Pharm ; 28(6): 325-330, 2021 11.
Article in English | MEDLINE | ID: mdl-32385068

ABSTRACT

OBJECTIVES: To determine prospectively the risk reducing measures of non-sterility during aseptic handling and to develop a method for prioritising these measures. METHODS: In the first part of this series of articles, we identified all sources of risk which could contaminate a product during aseptic handling, and calculated the remaining risks of non-sterility using a risk assessment (RA) model. We concluded that additional research of some risk sources was needed before risk control (RC) could be executed on all risk sources.The chances of technical problems with a laminar airflow cabinet or safety cabinet (LAF/SC) were collected from 10 hospital pharmacies using a questionnaire. The chances of blocking first air were examined by airflow visualisation (smoke studies). For checking the way of working during aseptic handling, a checklist for an audit was developed.Risk control was executed by a multidisciplinary team of (hospital) pharmacists and technicians, a consultant experienced in aseptic processing and an independent facilitator. They determined the risk reducing measures for each source of risk and the influence of these measures on the remaining risk (expressed as risk prioritisation number). RESULTS: The chances of defects of the LAF/SC were low. Airflow visualisation is a sensible method to find the correct location of materials and equipment inside the LAF/SC and to detect a way of working without blocking first air on critical spots. Audits will provide valuable information about the way aseptic handling is executed and the remaining risks as a consequence. The risk of non-sterility caused by needle or spike contact with critical spots of vials and ampoules (stopper or ampoule neck), blocking first air under downflow and touching critical spots cannot be eliminated completely. CONCLUSION: The RA/RC model shows the impact of risk reducing measures on the probability of non-sterility during aseptic handling. The calculated risk prioritisation numbers are helpful in prioritising these measures. Audits result in risk reduction for nearly all sources of risk.


Subject(s)
Pharmacies , Hospitals , Humans , Pharmacists , Risk Assessment
8.
Eur J Pharm Sci ; 155: 105540, 2020 Dec 01.
Article in English | MEDLINE | ID: mdl-32898638

ABSTRACT

Aseptic handling is the procedure to enable sterile products to be made ready to administer using closed systems (EU Resolution CM/Res(2016)2). Microbiological monitoring (MM) and media fills are used for environmental and process control. In this study, the application of MM methods during aseptic handling inside, or related to working in, a laminar airflow cabinet or safety cabinet in hospital pharmacies is described and evaluated. Results are expressed as colony forming units (cfu) and Contamination Recovery Rate (CRR; the rate at which MM samples contain any level of contamination -USP<1116>-). For trend analysis, a rolling CRR is developed (a rolling CRR calculates a CRR using a predetermined number of most recent samples). Of all MM methods, glove print is the most informative. The added value of air sampling is doubtful. Because of microbiological as well as statistical considerations, the use of CRR for assessing MM results is advised. Glove prints, in general, give the highest CRR. A CRR < 10% is a realistic limit for MM during aseptic handling in hospital pharmacies. A rolling CRR, calculated using the last 100 samples, is a good compromise between reliability of the CRR value and timely prediction of process changes.


Subject(s)
Drug Contamination , Environmental Monitoring , Reproducibility of Results
9.
BMC Cancer ; 10: 679, 2010 Dec 13.
Article in English | MEDLINE | ID: mdl-21144049

ABSTRACT

BACKGROUND: The pharmacotherapeutic treatment of patients with cancer is generally associated with multiple side-effects. Drug interactions and duplicate prescriptions between anti-cancer drugs or interactions with medication to treat comorbidity can reinforce or intensify side-effects.The aim of the present study is to gain more insight into the prevalence of drug interactions and duplicate prescriptions among patients being treated in the outpatient day care departments for oncology and hematological illnesses. For the first time the prevalence of drug interactions with OTC-drugs in cancer patients will be studied. Possible risk factors for the occurrence of these drug-related problems will also be studied. METHODS/DESIGN: A multicenter cross-sectional observational study of the epidemiology of drug interactions and duplicate prescriptions is performed among all oncology and hemato-oncology patients treated with systemic anti-cancer drugs at the oncology and hematology outpatient day care department of the VU University medical center and the Zaans Medical Center. DISCUSSION: In this article the prevalence of potential drug interactions in outpatient day-care patients treated with anti-cancer agents is studied using a novel more extensive screening method. If this study shows a high prevalence of drug interactions clinical pharmacists and oncologists must collaborate to develop a pharmaceutical screening programme, including an automated electronic warning system, to support drug prescribing for ambulatory cancer patient. This programme could minimize the occurrence of drug related problems such as drug interactions and duplicate prescriptions, thereby increasing quality of life. TRIAL REGISTRATION: This study is registered, number NTR2238.


Subject(s)
Ambulatory Care/statistics & numerical data , Antineoplastic Agents/therapeutic use , Drug Prescriptions/statistics & numerical data , Neoplasms/drug therapy , Nonprescription Drugs/therapeutic use , Pharmacy Service, Hospital/statistics & numerical data , Practice Patterns, Physicians'/statistics & numerical data , Research Design , Academic Medical Centers/statistics & numerical data , Antineoplastic Agents/adverse effects , Cross-Sectional Studies , Drug Interactions , Humans , Medication Errors/prevention & control , Medication Systems, Hospital , Netherlands , Nonprescription Drugs/adverse effects , Polypharmacy , Retrospective Studies