Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Acta Orthop Belg ; 90(1): 51-56, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38669649

ABSTRACT

Patient-specific instrumentation (PSI) was introduced to improve post-operative alignment, and consequently the revision rate and clinical results after total knee arthroplasty (TKA). Short- to mid-term data are conflicting regarding these theoretical advantages of PSI. The purpose of this retrospective analysis was to evaluate the survival rate and clinical outcome in PSI TKA 8.4 years after initial surgery. To our knowledge, no other study investigated long-term follow-up of TKA procedures using PSI. From a total cohort of 184 consecutive patients (200 TKA) 136 patients (144 TKA, 72%) were prospectively analysed at a mean follow-up of 8.4 years (±0.4). A survival analysis with all-cause revision of TKA as endpoint was performed. Patient-reported outcome measures (PROMs) were obtained preoperatively and after 1-, 2-, 5-, and 8.4-years of follow-up. Differences between these moments of follow-up were analysed. At final follow-up, 4 TKAs (2%) had undergone revision, all between 2-4 years after primary surgery. Reasons for revision were late infection, aseptic loosening, instability and polyethylene insert breakage. The median score of certain PROMs (WOMAC, VAS, EQ-index, EQ-VAS) decreased compared to previous follow-up scores but were significantly higher than preoperative scores. After 8.4 years of follow-up, no additional revision surgery was performed compared to 5-years postoperatively. Certain PROMs at 8.4-year follow-up decreased compared to earlier moments of follow-up, but all PROMs improved compared to preoperative PROMs.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Patient Reported Outcome Measures , Prosthesis Failure , Reoperation , Humans , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Male , Female , Aged , Reoperation/statistics & numerical data , Follow-Up Studies , Prospective Studies , Middle Aged , Retrospective Studies , Treatment Outcome , Aged, 80 and over
2.
Arthroplast Today ; 26: 101343, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38450396

ABSTRACT

Background: Optimization of clinical pathways and logistics led to the introduction of outpatient joint arthroplasty of the hip and knee. Nevertheless, little is known about what these current protocols look like and how they differ from "standard" inpatient protocols. This study aimed to find preoperative, intraoperative, and postoperative differences between outpatient and inpatient pathways. Methods: A questionnaire (ranging between 23 and 37 items) was developed and administered by email to orthopedic surgeons who were a member of the Dutch Hip Society and Dutch Knee Society. Survey response rate was 38% (N = 117). Results: No significant differences were found in preoperative pathway characteristics. The administration regime for tranexamic acid significantly differed between outpatient and inpatient pathways (P < .001 and P = .002 for hip and knee arthroplasty, respectively), with outpatient pathways using a combined (eg, oral and intravenous) administration regime more frequently. The perioperative antibiotic prophylaxis regime also significantly differed between outpatient and inpatient pathways (P < .001 and P = .014, respectively), with outpatient pathways more frequently incorporating fewer antibiotic doses. Same-day postoperative mobilization significantly less often occurred if surgery took place later that day in inpatient hip arthroplasty pathways (24%; P = .034). Postoperative hemoglobin-check occurred significantly more often on indication in outpatient than in inpatient hip and knee arthroplasty pathways (∼75% vs ∼25%; P = .001). Conclusions: Few intraoperative and postoperative differences in outpatient and inpatient pathways were found and probably mainly relied on logistical grounds. Nonetheless, findings suggested that outpatient pathways tended to be more up-to-date and innovative than inpatient pathways.

3.
Rhinology ; 2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38372647

ABSTRACT

BACKGROUND: Nasal hyperreactivity (NHR) is prevalent in all chronic upper airway inflammatory phenotypes, including allergic rhinitis (AR) and chronic rhinosinusitis with nasal polyps (CRSwNP). Although NHR in patients with non-allergic rhinitis is mediated by neuronal pathways, AR and CRSwNP are mainly characterized by type 2 inflammation. METHODS: Eighteen healthy controls and 45 patients with symptomatic AR/CRSwNP underwent a cold, dry air (CDA) provocation test for objective diagnosis of NHR. Before and after, questionnaires were filled out and nasal secretions and biopsies were collected. Markers for neurogenic inflammation (substance P, calcitonin gene-related peptide, neurokinin A), epithelial activation (IL-33), and histamine were measured in secretions by ELISA; and expression of neuronal markers PGP9.5, TRPV1, and TRPM8 was studied in biopsies by RT-q-PCR. Effects of histamine on TRPV1/A1 were studied with Ca2+-imaging using murine trigeminal neurons. RESULTS: CDA-provocation reduced peak nasal inspiratory flow (PNIF) of patients with subjective NHR but not of non-NHR controls/ patients (p.

4.
Eur J Orthop Surg Traumatol ; 34(1): 591-598, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37658912

ABSTRACT

PURPOSE: Different studies have shown that weightbearing is safe in stable transsyndesmotic, isolated lateral simple ankle fractures. Despite this evidence, AO guidelines still recommend immobilization with above-the-knee cast for 4-6 weeks for these fractures. The objective of this study was to compare the outcomes of mobilization and weightbearing to those of immobilization and non-weightbearing in patients with stable transsyndesmotic, lateral isolated simple ankle fractures. METHODS: Fifty patients were randomly assigned to permissive weightbearing in a walking boot or non-weightbearing immobilization using a below-the-knee cast. Primary outcome was ankle functionality as scored by the Olerud-Molander Ankle Score (OMAS). Secondary outcomes were radiological displacement of fracture, range of motion (ROM), calf circumference, and RAND 36-item health survey. Patients were in follow-up for 24 months. RESULTS: Ankle functionality after six and twelve weeks was significantly higher for the intervention group, with respectively 30 points (p = 0.001) and 10 points (p = 0.015) of difference. ROM improved significantly in the intervention group after six weeks. All fractures showed radiological progression of fracture healing. RAND 36-item showed differences in both physical (60.3 vs. 46.3, p = 0.017) and mental (78.5 vs. 58.2, p = 0.034) components in favor of the intervention group. In 16% of patients who initially showed stable fractures on radiographic imaging, joint dislocation was identified on weightbearing radiographs prior to randomization, leading to exclusion. CONCLUSION: Weightbearing and mobilization using a walking boot may be a safe treatment for patients with stable Weber B fractures.


Subject(s)
Ankle Fractures , Humans , Ankle Fractures/diagnostic imaging , Ankle Fractures/therapy , Prospective Studies , Conservative Treatment , Fracture Healing , Weight-Bearing , Treatment Outcome , Fracture Fixation, Internal/methods
5.
Knee Surg Sports Traumatol Arthrosc ; 31(11): 5137-5144, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37796308

ABSTRACT

PURPOSE: The aim of this prospective randomised controlled study was to compare wear characteristics and functional outcome between deep-dished mobile bearing (MB) and fixed bearing (FB) cemented total knee arthroplasty (TKA). We hypothesised that deep-dished MB reduces polyethylene wear and improves patient-reported outcome measures. METHODS: A total of 50 patients were randomised to receive a MB or FB tibia component of the same cemented TKA design. Patients were evaluated over a 5-year follow-up period. Medial and lateral wear were assessed using model-based Roentgen Stereophotogrammetric Analysis (RSA) and compared with the direct postoperative minimal joint space measurement. Functional outcome was assessed by the clinician-derived KSS and OKS, WOMAC, LEAS, and FJS-12. All data were derived using a general linear mixed model. RESULTS: At 5-year follow-up, decreased wear in the MB compared to the FB group was observed on the lateral side (0.07 ± 0.17 mm, p = 0.026), but not on the medial side (0.31 ± 0.055 mm, p = 0.665). Functional outcomes improved with a statistical significant effect over time, with no significant differences between groups (all p > 0.17). CONCLUSION: This model-based RSA study with 5-year follow-up showed that cemented deep-dished MB reduced lateral polyethylene wear as compared to FB in a single TKA system, whilst clinical outcomes were comparable. Longer follow-up is needed to establish clinical implications of these altered wear patterns and determine type of wear. LEVEL OF EVIDENCE: Level 1 randomised controlled trial.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Knee Joint/surgery , Prospective Studies , Prosthesis Design , Polyethylene , Osteoarthritis, Knee/surgery
6.
Article in English | MEDLINE | ID: mdl-37573271

ABSTRACT

PURPOSE: The purpose of this prospective randomized controlled trial was to compare the clinical outcome and the survival rate of total knee arthroplasty between CT- and MRI-based patient-specific instrumentation 5 years after initial surgery. METHODS: At a mean follow-up of 5.8 years (SD 0.3), 98 patients (64% women, loss to follow-up 28%) were included in this analysis. To assess the differences in clinical outcome, patients fulfilled PROMs preoperatively and at each follow-up moment. At final follow-up, the Forgotten Joint Score was adjusted. RESULTS: At final follow-up, no new patients underwent revision surgery in both groups. Regarding the clinical outcome, no statistically significant difference between the groups was found. The Forgotten Joint Score was only performed at final follow-up and showed no significant difference between both groups. CONCLUSION: At mid-term follow-up, survival rates between CT- and MRI-based patient-specific instrumentation did not show a significant difference. Regarding clinical outcome, only the EQ-5D-VAS (p < 0.040) showed a statistically significant difference over time, in favor of the MRI-group. LEVEL OF EVIDENCE: Level I.

7.
Arch Orthop Trauma Surg ; 142(8): 1775-1791, 2022 Aug.
Article in English | MEDLINE | ID: mdl-33587170

ABSTRACT

INTRODUCTION: This systematic review aimed to assess the safety and efficacy of outpatient joint arthroplasty (OJA) pathways compared to inpatient pathways. MATERIALS AND METHODS: An electronic literature search was conducted to identify eligible studies. Studies comparing OJA with inpatient pathways-following hip and/or (partial) knee arthroplasty-were included. Included studies were assigned-based on OJA definition-to one of the following two groups: (1) outpatient surgery (OS); outpatient defined as discharge on the same day as surgery; and (2) semi-outpatient surgery (SOS); outpatient defined as discharge within 24 h after surgery with or without an overnight stay. Methodological quality was assessed. Outcomes included (serious) adverse events ((S)AEs), readmissions, successful same-day discharge rates, patient-reported outcome measures (PROMs) and costs. Meta-analyses and subgroup analyses by type of arthroplasty were performed when deemed appropriate. RESULTS: A total of 41 studies (OS = 26, SOS = 15) met the inclusion criteria. One RCT and 40 observational studies were included, with an overall risk-of-bias of moderate to high. Forty studies were included in the meta-analysis. Outpatients (both OS and SOS) were younger and had a lower BMI and ASA class compared to inpatients. Overall, no significant differences between outpatients and inpatients were found for overall complications and readmission rates, and improvement in PROMs. By type of arthroplasty, only THAs in OS pathways were associated with fewer AEs [OR = 0.55 (0.41-0.74)] compared to inpatient pathways. 92% of OS patients were discharged on the day of surgery. OJA resulted in an average cost reduction of $6.797,02. CONCLUSION: OJA pathways are as safe and effective as inpatient pathways in selected populations, with a potential reduction of costs. Considerable risk of bias in the majority of studies emphasizes the need for further research.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Ambulatory Surgical Procedures/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Humans , Outpatients , Patient Discharge , Patient Readmission , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies
8.
J Clin Orthop Trauma ; 18: 144-149, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33996459

ABSTRACT

PURPOSE: The aim of this study was to provide a short term comparison in radiological and clinical outcome between Bi-Cruciate Retaining (BCR)- and Cruciate Retaining (CR) Total Knee Arthroplasty (TKA). METHODS: The cohort consists of 122 patients undergoing a TKA with PSI, equally distributed over the BCR- and CR-TKA group. Perioperative conditions were observed and radiological images were analysed pre-, 6-weeks, and 1-year postoperative to quantify alignment differences between BCR- and CR-TKA. Preoperatively predicted templates were compared with the implanted size to determine predictive value. In addition mean range of motion and revision rates were determined in both groups. RESULTS: No significant difference was observed in amount of outliers in component alignment between BCR- and CR-TKA. Outliers of the Hip-Knee-Ankle-Axis (HKA-axis) occurred significantly more frequent (P = 0.009) in the BCR-group (37.7%) compared to CR-TKA (18.0%). No clinically relevant differences regarding the predictive sizing of implant components was obtained. No significant differences were observed in revision rates (P = 1.000) and ROM (p = 0.425) between the BCR-groep and CR-group at 2-years FU. CONCLUSION: This study illustrates that although the HKA-axis was not fully restored, bi-cruciate retaining surgical technique for BCR-TKA is safe and effective with comparable radiological and clinical outcome as CR TKA. Randomized controlled trials with longer follow up on the HKA-axis alignment and clinical parameters are needed to confirm the presented results and should focus on possible cut off values concerning leg axis in order to define in what patients a BCR-TKA can safely be used. LEVEL OF EVIDENCE IV: Retrospective Case Controlled Study.

9.
Knee ; 28: 51-56, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33307319

ABSTRACT

BACKGROUND: The cruciate retaining lipped (CR-lipped) bearing is designed to provide more anterior-posterior (AP) stability and could be employed to resolve excessive intraoperative laxity during the cruciate retaining TKA (CR-TKA). The aim of the study was to determine whether the CR-lipped bearing in CR-TKAs with a perioperative excessive laxity allows equivalent functional results as compared to the standard CR articulation. METHODS: A cohort of 111 TKAs with CR-lipped bearings was matched to a cohort of conventional CR bearings regarding age and sex. The CR-lipped bearing was used in patients with excessive knee AP laxity and the regular CR bearing was used in patients without excessive AP laxity during TKA. Various PROMs (WOMAC, KSS, SF-36) were assessed preoperatively and at 5-years postoperative in combination with revision rate and Range of Motion (ROM). RESULTS: PROMs did not differ significantly between both groups 5-years postoperatively. Mean ROM (flexion) 5-years postoperatively was not significantly different. The implant survivorship was 100% for both cohorts with revision for any reason as end point. CONCLUSION: Based on these results, the CR-lipped bearing is a safe and effective solution for mild interoperatively assessed PCL laxity during CR-TKA without loss of function or decreased survivorship at 5 years. Peroperative conversion to a PS-TKA in order to obtain satisfactory functional scores might therefore not be necessary when mild PCL laxity is observed during surgery. Further research should focus on verifying this approach and longer follow-up is needed to generate data on long term survivorship. LEVEL OF EVIDENCE: Level IV therapeutic, retrospective, cohort study.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Joint Instability/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Aged , Aged, 80 and over , Female , Humans , Knee Joint/surgery , Male , Middle Aged , Posterior Cruciate Ligament/surgery , Prosthesis Design , Range of Motion, Articular , Retrospective Studies
10.
J Eur Acad Dermatol Venereol ; 33 Suppl 2: 97-103, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30811700

ABSTRACT

The incidence of non-melanoma and melanoma skin cancer has been rising in Europe. Although the World Health Organization's International Agency for Research on Cancer has since 2009 classified sunbeds as a Group 1 carcinogen, sunbed use, especially by those under the age of 18, continues to be a concern. As the only platform for cancer leagues in Europe, the Association of European Cancer Leagues decided to explore interest and actions by its member leagues at the national level against sunbed use, to share experiences and to provide background information on possible future collective actions at the EU level.


Subject(s)
Health Education , Health Promotion , Organizations , Skin Neoplasms/prevention & control , Sunbathing , Ultraviolet Rays/adverse effects , Adolescent , Adult , Aged , Belgium , Female , Health Education/methods , Health Promotion/methods , Humans , Intersectoral Collaboration , Legislation as Topic , Lobbying , Male , Middle Aged , Northern Ireland , Skin Neoplasms/etiology , Sunbathing/legislation & jurisprudence , Surveys and Questionnaires , Young Adult
11.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1463-1468, 2019 May.
Article in English | MEDLINE | ID: mdl-29725747

ABSTRACT

PURPOSE: The purpose of this multicentre prospective randomized controlled trial was to compare the survival rate and clinical outcome in total knee arthroplasty (TKA) after MRI-based patient-specific instruments (PSI) and conventional instruments 5 years after initial surgery. METHODS: At a mean follow-up of 5.1 years (0.4), 163 patients (90.6%) with a mean age of 71.8 years (8.7) were analysed. A survival analysis with revision of the TKA as endpoint was performed. The Knee Society Score (KSS), evaluations on plain radiographs and patient-reported outcome measures (PROMs) were obtained preoperatively and at each FU. RESULTS: At final follow-up, one TKA in the PSI- (1.2%) and 3 TKAs in the conventional group (3.8%) had undergone revision surgery (n.s.). No radiological abnormalities were noted at any time point. Postoperatively, the KSS and PROMs significantly improved within each group compared with the preoperative values. There were no clinically relevant differences for the KSS [PSI: 77.4, 9.8 (95% CI 75.0-79.7) vs. conventional: 77.3 10.5 (95% CI 74.9-79.8)] and the PROMs between both groups (n.s.) at 5 years follow-up. CONCLUSION: There is still a lack of reliable data on the survival of TKA and clinical evidence, when using PSI for TKA. Longer follow-up studies are, therefore, needed. LEVEL OF EVIDENCE: I.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Aged , Arthroplasty, Replacement, Knee/instrumentation , Double-Blind Method , Follow-Up Studies , Humans , Knee/surgery , Magnetic Resonance Imaging , Middle Aged , Osteoarthritis, Knee/mortality , Patient Reported Outcome Measures , Postoperative Complications , Postoperative Period , Prospective Studies , Radiography , Reoperation
12.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1469, 2019 May.
Article in English | MEDLINE | ID: mdl-29799065

ABSTRACT

In the original article, one of the co-author's (W. van der Weegen) middle name has been missed in the publication of the article. The correct complete name should be W. van der Weegen.

13.
Knee Surg Sports Traumatol Arthrosc ; 26(6): 1656-1661, 2018 Jun.
Article in English | MEDLINE | ID: mdl-28785788

ABSTRACT

PURPOSE: Patient-specific instruments (PSI) were initially developed for the alignment of both total knee- (TKA) and partial knee arthroplasty (PKA). We hypothesize that CT-based PSI for PKA-to-TKA revision surgery can restore biomechanical limb alignment and prosthetic component positioning in vivo as calculated pre-operatively, resulting in a limited percentages of outliers. METHODS: An imaging analysis was performed using CT-based 3D measurement methods based on a pre- and post-revision CT scan. Imaging data were gathered on 10 patients who were operated for PKA-to-TKA revision with the use of PSI based on CT imaging. The planned femur and tibia component position in vivo were compared with the pre-revision planned component position. Outliers were defined as deviations >3.0° from pre-revision planned position for the individual implant components. Adjustments (e.g. resection level and implant size) during surgery were recorded. RESULTS: The HKA axis was restored accurately in all patients with a mean post-operative HKA axis of 178.1° (1.4°). Five femoral (2 varus, 2 internal rotation and 1 extension) and 14 tibial guides (2 varus, 6 anterior slope, 3 internal rotation and 3 external rotation) on a total of 60 outcome measures were identified as outliers. During surgery, an intraoperative tibial resection of 2 mm extra was performed in three patients. In 80 and 70% for, respectively, the femur and tibia, the surgeon-planned size was implanted during surgery. All patient-specific guides fitted well in all patients. No intraoperative or post-operative complications related to surgery were registered. CONCLUSIONS: This study introduced a unique new concept regarding PSI, PKA-to-TKA revision surgery. Based on the results, we were unable to fully confirm our hypothesis. PSI as a "new" tool for PKA-to-TKA revision surgery appears to be an accurate tool for the alignment of the TKA femur component. The tibial guide seems more susceptible to errors, resulting in a substantial percentage of outliers. LEVEL OF EVIDENCE: Prospective cohort study, Level II.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Bone Malalignment/surgery , Femur/surgery , Joint Diseases/surgery , Reoperation/instrumentation , Aged , Biomechanical Phenomena , Bone Malalignment/etiology , Female , Femur/diagnostic imaging , Femur/physiopathology , Humans , Joint Diseases/physiopathology , Knee Joint/diagnostic imaging , Knee Joint/surgery , Knee Prosthesis , Male , Middle Aged , Patient-Specific Modeling , Prospective Studies , Reoperation/methods , Rotation , Surgery, Computer-Assisted , Tibia/diagnostic imaging , Tibia/physiopathology , Tibia/surgery , Tomography, X-Ray Computed
14.
Knee Surg Sports Traumatol Arthrosc ; 26(6): 1823-1830, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29282486

ABSTRACT

PURPOSE: Patient-specific instrumentation (PSI) is a technique to plan and position the prosthesis components in unicompartmental knee arthroplasty (UKA) surgery. This study assesses whether the definitive component position in the frontal, sagittal and axial plane is according to the preoperative plan, based on the hypothesis that PSI is accurate. METHODS: Twenty-six patients who had PSI Oxford UKA surgery were included prospectively. The component position in vivo was determined with a postoperative CT-scan and compared with the planned component position using MRI-based digital 3D imaging. Adjustments to the preoperative plan and implanted component sizes during surgery were recorded. RESULTS: Intraoperatively, no femoral adjustments were performed; 12 tibial re-resections were necessary. The median absolute deviation from the plan in degrees (range) in the frontal, sagittal and axial plane was 1.8° (- 1.5°-6.5°), 2.0° (- 6.5°-8.0°) and 1.0° (- 1.5°-5.0°) for the femoral component, and 2.5° (- 1.0°-6.0°), 3.0° (- 1.0°-5.0°) and 5.0° (- 6.5°-12.5°) for the tibial component. The femoral component is positioned 0.5 (- 1°-2.5°) mm more lateral and 0.8 (- 1.0°-2.5°) mm more anterior. The tibial component is positioned 2.0 (- 5.0-0.0) mm more lateral and 1.3 (- 3.0-6.0) mm more distal. The femoral and tibial default plans were changed four times (15.4%) and nine times (34.6%), respectively, before approval by the surgeon. CONCLUSION: PSI in Oxford UKA surgery is reliable and accurately translates the preoperative plan into the in vivo situation, except for the tibial rotational position. The preoperative planning is a crucial step in avoiding re-resections that can cause angular deviations in prosthesis position, especially in tibial component rotational position. It is advised to avoid re-resections and to consider this while planning the PSI procedure. LEVEL OF EVIDENCE: Prospective comparative study Level II.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Bone Malalignment/diagnostic imaging , Knee Prosthesis , Osteoarthritis, Knee/surgery , Surgery, Computer-Assisted/instrumentation , Tibia/surgery , Aged , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Bone Malalignment/physiopathology , Bone Malalignment/surgery , Female , Femur/physiopathology , Femur/surgery , Humans , Knee Joint/diagnostic imaging , Knee Joint/physiopathology , Knee Joint/surgery , Knee Prosthesis/adverse effects , Male , Middle Aged , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/physiopathology , Prospective Studies , Reproducibility of Results , Rotation , Surgery, Computer-Assisted/adverse effects , Surgery, Computer-Assisted/methods , Tibia/physiopathology
15.
Knee Surg Sports Traumatol Arthrosc ; 25(3): 703-709, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27161197

ABSTRACT

PURPOSE: Although fewer tibial radiolucent lines are observed in cementless Oxford unicompartmental knee arthroplasty (UKA) compared with cemented Oxford UKA, an independent comparative study on this topic is lacking. METHODS: In this multicentre retrospective study, a cohort of 60 consecutive cases of cementless Oxford UKA is compared with a cohort of 60 consecutive cases of cemented Oxford UKA. Radiolucent lines, survival, perioperative data and clinical results were compared. RESULTS: No complete tibial radiolucent lines were observed in either group. Seventeen per cent of partial tibial radiolucent lines were observed in the cementless group versus 21 % in the cemented group (n.s.). The percentage of tibial radiolucent zones was 4 versus 9 %, respectively (p = 0.036). Survival rates were 90 % at 34 months for the cementless group and 84 % at 54 months for the cemented group (n.s.). Mean operation time was 10 min shorter in the cementless group (p < 0.001), and clinical results were not significantly different. CONCLUSIONS: Although no significant differences in radiolucent lines were found between both groups, they appear to be more common in the cemented group. This confirms previous results from reports by prosthesis designers. The presence of radiolucent lines after cemented Oxford UKA does not correlate with clinical outcome or survival. LEVEL OF EVIDENCE: III.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Knee Prosthesis , Osteoarthritis, Knee/surgery , Postoperative Complications/diagnostic imaging , Prosthesis Design , Tibia/diagnostic imaging , Aged , Aged, 80 and over , Bone Cements , Case-Control Studies , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Retrospective Studies , Treatment Outcome
16.
Int J Colorectal Dis ; 32(3): 305-313, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27942836

ABSTRACT

INTRODUCTION: Despite extensive research, anastomotic leakage (AL) remains one of the most dreaded complications after colorectal surgery. Since butyrate enemas are known to enhance anastomotic healing, several administration routes have been explored in this study. METHODS: Three intraluminal approaches involving butyrate were investigated: (1) butyrin-elucidating patch, (2) a single injection of hyaluronan-butyrate (HA-But) prior to construction of the proximal anastomosis and (3) rectal hyaluronan-butyrate (HA-But) enemas designed for distal anastomoses. The main outcome was AL and secondary outcomes were bursting pressure, histological analysis of the anastomosis, zymography to detect MMP activity and qPCR for gene expression of MMP2, MMP9, MUC2 and TFF3. RESULTS: Neither the patches nor the injections led to a reduction of AL in experiments 1 and 2. In experiment 3, a significant reduction of AL was accomplished with the (HA-But) enema compared to the control group together with a higher bursting pressure. Histological analysis detected only an increased inflammation in experiment 2 in the hyaluronan injection group compared to the control group. No other differences were found regarding wound healing. Zymography identified a decreased proenzyme of MMP9 when HA-But was administered as a rectal enema. qPCR did not show any significant differences between groups in any experiment. CONCLUSION: Butyrate enemas are effective in the enhancement of colonic anastomosis. Enhanced butyrate-based approaches designed to reduce AL in animal models for both proximal and distal anastomoses were not more effective than were butyrate enemas alone. Further research should focus on how exogenous butyrate can improve anastomotic healing after gastrointestinal surgery.


Subject(s)
Butyric Acid/administration & dosage , Butyric Acid/pharmacology , Colon/drug effects , Colon/surgery , Anastomosis, Surgical , Anastomotic Leak/pathology , Animals , Collagen/metabolism , Drug Administration Routes , Gene Expression Regulation/drug effects , Inflammation/pathology , Matrix Metalloproteinases/metabolism , Pressure , Rats, Wistar , Real-Time Polymerase Chain Reaction
17.
Bone Joint J ; 98-B(7): 939-44, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27365472

ABSTRACT

AIMS: We wished to compare the clinical outcome, as assessed by questionnaires and the rate of complications, in total knee arthroplasty (TKA) undertaken with patient-matched positioning guides (PMPGs) or conventional instruments. PATIENTS AND METHODS: A total of 180 patients (74 men, 106 women; mean age 67 years) were included in a multicentre, adequately powered, double-blind, randomised controlled trial. The mean follow-up was 44 months (24 to 57). RESULTS: There were no significant or clinically relevant differences between the two groups for all outcome measures (Knee Society Score, p = 0.807; Oxford Knee Score, p = 0.304; Western Ontario and McMaster osteoarthritis index, p = 0.753; visual analogue scale for pain, p = 0.227; EuroQol-5D-3L index score, p = 0.610; EuroQol-5D-3L VAS health, p = 0.968.) There was no difference in the rate of complications (p = 0.291). CONCLUSION: PMPGs are already in relatively common use and their short-term clinical results are equal to conventional instrumented TKA. Cite this article: Bone Joint J 2016;98-B:939-44.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Aged , Computer-Aided Design , Double-Blind Method , Female , Follow-Up Studies , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Male , Osteoarthritis, Knee/surgery , Postoperative Complications , Preoperative Care , Surveys and Questionnaires , Visual Analog Scale
18.
Knee ; 23(1): 20-4, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26746040

ABSTRACT

BACKGROUND: Long-leg radiographs (LLR) are often used in orthopaedics to assess limb alignment in patients undergoing total knee arthroplasty (TKA). However, there are still concerns about the adequacy of measurements performed on LLR. We assessed the reliability and validity of measurements on LLR using three-dimensional computed tomography (3D CT)-scan as a gold standard. METHODS: Six different surgeons measured the mechanical axis and position of the femoral and tibial components individually on 24 LLR. Intraclass correlation coefficients (ICC) were calculated to obtain reliability and Bland-Altman plots were constructed to assess agreement between measurements on LLR and measurements on 3D CT-scan. RESULTS: ICC agreement for the six observer measurements on LLR was 0.70 for the femoral component and 0.80 for the tibial component. The mean difference between measurements performed on LLR and 3D CT-scan was 0.3° for the femoral component and -1.1° for the tibial component. Variation of the difference between LLR and 3D CT-scan for the femoral component was 1.1° and 0.9° for the tibial component. 95% of the differences between measurements performed on LLR and 3D CT-scan were between -1.9 and 2.4° (femoral component) and between -2.9 and 0.7 (tibial component). CONCLUSION: Measurements on LLR show moderate to good reliability and, when compared to 3D CT-scan, show good validity. CLINICAL TRIAL REGISTRATION NUMBER: institutional review board Atrium-Orbis-Zuyd, number: 11-T-15. LEVEL OF EVIDENCE: Prospective cohort study, Level II.


Subject(s)
Arthroplasty, Replacement, Knee , Femur/diagnostic imaging , Imaging, Three-Dimensional/methods , Knee Joint/surgery , Leg/diagnostic imaging , Tibia/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Female , Femur/surgery , Humans , Knee Joint/diagnostic imaging , Male , Middle Aged , Prospective Studies , ROC Curve , Reproducibility of Results , Tibia/surgery
19.
Bone Joint J ; 95-B(9): 1204-8, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23997133

ABSTRACT

Although it has been suggested that the outcome after revision of a unicondylar knee replacement (UKR) to total knee replacement (TKR) is better when the mechanism of failure is understood, a comparative study on this subject has not been undertaken. A total of 30 patients (30 knees) who underwent revision of their unsatisfactory UKR to TKR were included in the study: 15 patients with unexplained pain comprised group A and 15 patients with a defined cause for pain formed group B. The Oxford knee score (OKS), visual analogue scale for pain (VAS) and patient satisfaction were assessed before revision and at one year after revision, and compared between the groups. The mean OKS improved from 19 (10 to 30) to 25 (11 to 41) in group A and from 23 (11 to 45) to 38 (20 to 48) in group B. The mean VAS improved from 7.7 (5 to 10) to 5.4 (1 to 8) in group A and from 7.4 (2 to 9) to 1.7 (0 to 8) in group B. There was a statistically significant difference between the mean improvements in each group for both OKS (p = 0.022) and VAS (p = 0.002). Subgroup analysis in group A, performed in order to define a patient factor that predicts outcome of revision surgery in patients with unexplained pain, showed no pre-operative differences between both subgroups. These results may be used to inform patients about what to expect from revision surgery, highlighting that revision of UKR to TKR for unexplained pain generally results in a less favourable outcome than revision for a known cause of pain.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Osteoarthritis, Knee/surgery , Prosthesis Failure/adverse effects , Adult , Aged , Arthroplasty, Replacement, Knee/statistics & numerical data , Female , Humans , Male , Middle Aged , Pain, Postoperative/etiology , Pain, Postoperative/surgery , Patellofemoral Pain Syndrome/etiology , Patellofemoral Pain Syndrome/surgery , Reoperation/statistics & numerical data , Retrospective Studies , Treatment Outcome
20.
Knee Surg Sports Traumatol Arthrosc ; 21(10): 2206-12, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23928929

ABSTRACT

PURPOSE: This prospective, double-blind, randomised controlled trial was designed to address the following research questions: firstly, is there a significant difference in outliers in alignment in the frontal and sagittal plane between PSG TKA and conventional TKA. Secondly, is there a significant difference in operation time, blood loss and length of hospital stay between the two techniques. We hypothesise that there will be fewer outliers with PSG TKA and that operation time, blood loss and length of hospital stay can be significantly reduced with PSG. METHODS: A total of 180 patients were randomised for PSG TKA (group 1) or conventional TKA (group 2) in two centres. Patients were stratified per hospital. Alignment of the mechanical axis of the leg and flexion/extension and varus/valgus of the individual prosthesis components were measured on digital, standing, long-leg and standard lateral radiographs by two independent outcome assessors in both centres. Percentages of outliers (>3°) were determined. We compared blood loss, operation time and length of hospital stay. RESULTS: There was no statistically significant difference in mean mechanical axis or outliers in mechanical axis between groups. No statistically significant difference was found for the alignment of the individual components in the frontal plane nor for the percentages of outliers. There was a statistically significant difference in outliers for the femoral component in the sagittal plane, with a higher percentage of outliers in the group 1 (p = 0.017). No such significant result was found for the tibial component in that plane. All interclass correlation coefficients were good. Blood loss was 100 mL less in group 1 (p < 0.001). Operation time was 5 min shorter in group 1 (p < 0.001). Length of hospital stay was identical with a mean of 3.6 days (p = 0.657). CONCLUSIONS: The results in terms of obtaining a neutral mechanical axis and a correct position of the prosthesis components did not differ between groups. A small reduction in operation time and blood loss was found with the PSG system. Future research should especially focus on cost-effectiveness analysis and functional outcome of PSG TKA. LEVEL OF EVIDENCE: I.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Bone Malalignment/prevention & control , Knee Joint/diagnostic imaging , Osteoarthritis, Knee/surgery , Postoperative Complications/prevention & control , Preoperative Care/methods , Surgery, Computer-Assisted/methods , Aged , Arthroplasty, Replacement, Knee/instrumentation , Blood Loss, Surgical/statistics & numerical data , Bone Malalignment/diagnostic imaging , Bone Malalignment/etiology , Double-Blind Method , Female , Follow-Up Studies , Humans , Intraoperative Period , Knee Joint/surgery , Knee Prosthesis , Length of Stay/statistics & numerical data , Magnetic Resonance Imaging , Male , Middle Aged , Operative Time , Osteoarthritis, Knee/diagnostic imaging , Postoperative Complications/diagnostic imaging , Preoperative Care/instrumentation , Prospective Studies , Radiography , Surgery, Computer-Assisted/instrumentation , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...