Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
2.
JBJS Case Connect ; 13(1)2023 01 01.
Article in English | MEDLINE | ID: mdl-36928114

ABSTRACT

CASE: A 53-year-old woman with a history of transfemoral amputation presented to the emergency department with an ipsilateral intertrochanteric femur fracture. Standard fracture tables that use a boot to pull traction are not helpful in these cases, which makes achieving adequate traction for reduction difficult. CONCLUSION: We describe a unique technique to manipulate an amputated extremity using 2 Schanz pins attached to a weight through a traction rope. This practical technique provided adequate skeletal traction for reduction and internal fixation in our case and can be performed on a standard radiolucent table without the need for special table attachments.


Subject(s)
Hip Fractures , Traction , Female , Humans , Middle Aged , Traction/methods , Hip Fractures/surgery , Fracture Fixation, Internal , Amputation, Surgical , Femur/surgery
3.
Eur J Orthop Surg Traumatol ; 33(6): 2555-2563, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36645494

ABSTRACT

INTRODUCTION: Hip fractures are common injuries in the elderly, with an incidence that continues to rise. The femoral neck system (FNS) recently emerged as a novel treatment option for femoral neck fractures, but long-term survivability of the implant remains uncertain. The purpose of this study is to evaluate survivability of the FNS and assess risk factors for implant failure. METHODS: One hundred five adult patients who received the FNS (DePuy Synthes, Raynham, MA) for femoral neck fractures (AO/OTA 31B) were included. Surgeries were performed within a regional hospital system comprising 18 facilities. All patients had a minimum follow-up of 1 year. The primary outcome measures were cumulative incidence of implant failure and 1-year mortality, including risk factor analysis. RESULTS: Twelve implants failed at a follow-up ranging from 17 days to 8 months, and 7 failed within 90 days. Cumulative incidence of implant failure was 2% at 30 days, 7% at 90 days, 12% at 6 months, and 13% at 1 year. Causes of implant failure included cut-out (n = 5), non-union (n = 4), peri-implant fracture (n = 2), and avascular necrosis (n = 1). Univariate Cox regression identified Pauwels type III fractures and an increasing AP Parker ratio as significant risk factors for failure. Pauwels type III fractures showed a 5.48 times higher risk compared to Pauwels types I & II. Every 10% increase in AP Parker ratio increased risk of failure by 2.39 times. The 1-year mortality rate was 21%, and univariate logistic regression identified age as the only risk factor (odds ratio = 3.71). CONCLUSIONS: The incidence of implant failure and 1-year mortality rate in this study suggests that the FNS can provide reliable fixation compared to rates in the literature, but complications are not uncommon. Avoiding Pauwels type III fractures and optimizing implant placement appear crucial to preventing implant failure. LEVEL OF EVIDENCE: Therapeutic Level IV.


Subject(s)
Femoral Neck Fractures , Osteonecrosis , Humans , Adult , Aged , Femur Neck , Fracture Fixation, Internal/adverse effects , Femoral Neck Fractures/surgery , Risk Factors , Treatment Outcome , Retrospective Studies
4.
Cureus ; 14(8): e28474, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36176851

ABSTRACT

While amputation techniques have improved over time, questions remain around how to best treat neuromas and severed nerves in the amputee population, specifically for trauma-related amputees. This systematic review investigates and summarizes outcomes following targeted muscle reinnervation (TMR) for the trauma-related amputee population. Studies were classified based on primary or secondary TMR and relevant outcomes, including the ability to use a prosthesis, post-TMR opioid use, Patient-Reported Outcomes Measurement Information System (PROMIS) scores for phantom limb pain and residual limb pain, and overall pain resolution/reduction. Following TMR for trauma-related amputation, most patients experienced neuroma pain resolution (86.2%, 95% confidence interval [CI]: 67.2-95.0%) and overall pain reduction/resolution (90.7%, 95% CI: 82.2-95.4%). No differences were seen between primary and secondary TMR. Preliminary evidence indicates that TMR is effective for preventing or treating pain in patients with trauma-related amputation, whether used in the acute or delayed setting.

SELECTION OF CITATIONS
SEARCH DETAIL
...