Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 65
Filter
1.
Cardiovasc Ultrasound ; 13: 13, 2015 Mar 21.
Article in English | MEDLINE | ID: mdl-25889047

ABSTRACT

BACKGROUND: Participation of amateur runners in endurance races continues to increase. Previous studies of marathon runners have raised concerns about exercise-induced myocardial and renal dysfunction and damage. In our pooled analysis, we aimed to characterize changes of cardiac and renal function after marathon running in a large cohort of mostly elderly amateur marathon runners. METHODS: A total of 167 participants of the Berlin-Marathon (female n = 89, male n = 78; age = 50.3 ± 11.4 years) were included and cardiac and renal function was analyzed prior to, immediately after and 2 weeks following the race by echocardiography and blood tests (including cardiac troponin T, NT-proBNP and cystatin C). RESULTS: Among the runners, 58% exhibited a significant increase in cardiac biomarkers after completion of the marathon. Overall, the changes in echocardiographic parameters for systolic or diastolic left and right ventricular function did not indicate relevant myocardial dysfunction. Notably, 30% of all participants showed >25% decrease in cystatin C-estimated glomerular filtration rate (GFR) from baseline directly after the marathon; in 8%, we observed a decline of more than 50%. All cardiac and renal parameters returned to baseline ranges within 2 weeks after the marathon. CONCLUSIONS: The increase in cardiac biomarkers after completing a marathon was not accompanied by relevant cardiac dysfunction as assessed by echocardiography. After the race, a high proportion of runners experienced a decrease in cystatin C-estimated GFR, which is suggestive of transient, exercise-related alteration of renal function. However, we did not observe persistent detrimental effects on renal function.


Subject(s)
Echocardiography/methods , Heart Ventricles/diagnostic imaging , Kidney/physiology , Physical Endurance/physiology , Running/physiology , Ventricular Function, Left/physiology , Aged , Athletic Performance/physiology , Cohort Studies , Heart Function Tests , Humans , Kidney Function Tests , Male , Middle Aged , Physical Fitness/physiology , Young Adult
2.
Cardiovasc Ultrasound ; 12: 13, 2014 Mar 29.
Article in English | MEDLINE | ID: mdl-24678809

ABSTRACT

BACKGROUND: Subclinical myocardial involvement is common in systemic sclerosis (SSc) and associated with poor prognosis. Early detection, particularly during follow-up, is important. Two-dimensional speckle tracking echocardiography (STE) has already been shown to detect early left ventricular systolic impairment in SSc patients with advanced disease. The aim of this study was to assess the ability of STE to diagnose changes in left ventricular function in patients with SSc with preserved LV ejection fraction (LVEF) and normal pulmonary pressure over time. METHODS: This single-center pilot study included nineteen SSc patients without pulmonary hypertension and preserved LVEF (55.2 ± 10.8 years, 13 women, mean modified Rodnan Skin Score of 8.2 ± 6.5, median disease duration 6 ± 4.5 years). We performed STE at baseline and after two years (mean 756.6 ± 8.8 days). Pulmonary hypertension was ruled out in all patients by right heart catheterization (average mean PAP 17.7 ± 3.5 mmHg). RESULTS: The LVEF remained unchanged (63.3 ± 4.2% vs. 63.2 ± 5.0%, P = ns), but the global longitudinal peak systolic strain of the left ventricle was significantly lower: baseline -22.0 ± 2.3% vs. follow-up -20.8 ± 2.1% (P = 0.04). The regional analysis showed a heterogeneous distribution of segmental systolic dysfunction that did not match any particular coronary artery distribution. In contrast, the LV diastolic function remained stable during follow-up. CONCLUSION: STE might be a sensititive and valuable method to detect early LV systolic impairment in patients with SSc and preserved LVEF during two years. Prospective evaluations are needed for prognostic implications of these changes.


Subject(s)
Echocardiography/methods , Scleroderma, Systemic/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Adult , Aged , Echocardiography/statistics & numerical data , Female , Follow-Up Studies , Humans , Longitudinal Studies , Male , Middle Aged , Observer Variation , Pilot Projects , Prognosis , Retrospective Studies , Scleroderma, Systemic/complications , Stroke Volume , Systole , Ventricular Dysfunction, Left/etiology , Ventricular Function, Left
3.
Cardiovasc Ultrasound ; 12: 11, 2014 Feb 26.
Article in English | MEDLINE | ID: mdl-24571726

ABSTRACT

BACKGROUND: Regular physical activity reduces cardiovascular risk. There is concern that Marathon running might acutely damage the heart. It is unknown to what extent intensive physical endurance activity influences the cardiac mechanics at resting condition. METHODS: Eighty-four amateur marathon runners (43 women and 41 men) from Berlin-Brandenburg area who had completed at least one marathon previously underwent clinical examination and echocardiography at least 10 days before the Berlin Marathon at rest. Standard transthoracic echocardiography and 2D strain and strain rate analysis were performed. The 2D Strain and strain rate values were compared to previous published data of healthy untrained individuals. RESULTS: The average global longitudinal peak systolic strain of the left ventricle was -23 +/- 2% with peak systolic strain rate -1.39 +/- 0.21/s, early diastolic strain rate 2.0 +/- 0.40/s and late diastolic strain rate 1.21 +/- 0.31/s. These values are significantly higher compared to the previous published values of normal age-adjusted individuals. In addition, no age-related decline of longitudinal contractility in well-trained athletes was observed. CONCLUSIONS: There is increased overall longitudinal myocardial contractility at rest in experienced endurance athletes compared to the published normal values in the literature indicating a preserved and even supra-normal contractility in the athletes. There is no age dependent decline of the longitudinal 2D Strain values. This underlines the beneficial effects of regular physical exercise even in advanced age.


Subject(s)
Echocardiography/methods , Elasticity Imaging Techniques/methods , Heart Ventricles/diagnostic imaging , Myocardial Contraction/physiology , Physical Endurance/physiology , Running/physiology , Ventricular Function, Left/physiology , Athletic Performance/physiology , Elastic Modulus/physiology , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Stress, Mechanical
4.
Eur J Prev Cardiol ; 21(10): 1192-9, 2014 Oct.
Article in English | MEDLINE | ID: mdl-23723328

ABSTRACT

BACKGROUND: Galectin-3 is a new and promising biomarker for heart failure and myocardial fibrosis. Although endurance exercise is a crucial element in cardiovascular disease prevention, the relationship between exercise and plasma levels of galectin-3 is still unknown. To date, the relationship between regular exercise and myocardial fibrosis is not fully understood. This study investigates the relationship between endurance exercise and plasma levels of galectin-3. METHODS: Twenty-one male, healthy non-elite marathon runners were examined before and within 1 hour after a strenuous run of 30 km after 4-day training abstinence. Examination included blood samples for galectin-3, echocardiography, and cardiac magnetic resonance imaging (CMR). In addition, to distinguish between cardiac or skeletal muscular origin of galectin-3, 27 C57Bl/6 J mice performing voluntary wheel running and 25 sedentary mice were analysed. RESULTS: Plasma galectin-3 in endurance athletes increased from baseline to post exercise (12.8 ± 3.4 ng/ml to 19.9 ± 3.9 ng/ml, p < 0.001) while the systolic left and right ventricular function remained unchanged. Interestingly, baseline plasma levels of galectin-3 were in normal range but higher than in healthy sedentary controls. However, in CMR there was no correlation between baseline galectin-3 levels and the detection of myocardial fibrosis. In animal studies, the relative level of mRNA for galectin-3 in active mice was significantly higher compared to sedentary mice. This increase was most pronounced in skeletal muscle (98.0% higher, p < 0.001) and not in the myocardium of the left ventricle (19.9% higher, p = 0.043). CONCLUSIONS: Plasma galectin-3 is substantially elevated in endurance athletes after running but does not correlate with cardiac function, other biomarkers, or myocardial fibrosis. In mice, we demonstrate that galectin-3 increase during endurance exercise originates primarily from skeletal muscle.


Subject(s)
Athletes , Galectin 3/blood , Physical Endurance , Adult , Animals , Biomarkers/blood , Blood Proteins , Echocardiography , Fibrosis , Galectin 3/genetics , Galectin 3/metabolism , Galectins , Humans , Magnetic Resonance Imaging , Male , Mice, Inbred C57BL , Middle Aged , Muscle, Skeletal/metabolism , Myocardium/metabolism , Myocardium/pathology , RNA, Messenger/metabolism , Running , Systole , Time Factors , Up-Regulation , Ventricular Function, Left , Ventricular Function, Right
5.
J Tissue Eng ; 4: 2041731413504777, 2013.
Article in English | MEDLINE | ID: mdl-24020013

ABSTRACT

This clinical study was performed to investigate the patency rate of endothelial cell-seeded small-diameter expanded polytetrafluoroethylene grafts during coronary artery bypass surgery. Between September 1995 and December 1998, 14 patients (median age: 71 years, range: 61-79 years) received 21 endothelial cell-seeded small-diameter grafts. In all, 43% of the performed implantations were reoperations. Endothelial cells were harvested from a forearm vein, cultured and characterized in the laboratory until a sufficient number was available. After in vitro seeding, the grafts were allowed to mature for another 10 days, prior to implantation. Graft patency was investigated with angiography, angioscopy, and intravascular ultrasonography during follow-up. Cumulative data represented 58 patients' years and was 100% complete. The seeded autologous vascular endothelial cell density was 1.05 × 10(5) ± 0.12 × 10(5) cells/cm(2) with a cell viability of 95.5 ± 1.5%. Operative mortality was 7.1% (one patient). Patency rate at discharge was 95.2%, and at a mean follow-up of 27 months was 90.5%. The proven patency rate at up to 72 months was at least 50.0%, as five patients refused angiographic evaluation. None of these five patients suffered from angina pectoris and so the best scenario would have shown a patency rate of 85.7%. Angioscopy and intravascular ultrasonography showed absence of atheroma or stenosis in the investigated patent grafts. Autologous vascular endothelial cell seeding improves patency rate of small-caliber expanded polytetrafluoroethylene grafts in patients without suitable autologous graft material.

6.
Clin Biochem ; 46(15): 1615-8, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23810852

ABSTRACT

OBJECTIVE: Chronic Chagas disease afflicts millions of patients in Latin America of which 70% remain asymptomatic but 30% develop fatal heart injury. To evaluate the impact of laboratory medicine for diagnosis and guiding of patients with Chagas' heart disease, we measured N-terminal B-type natriuretic peptide (NT-proBNP) and cardiac troponin T (cTnT). DESIGN AND METHODS: NT-proBNP and cTnT using the highly sensitive assay (hs-cTnT) were measured in 48 asymptomatic Chagas' patients (control group; (-) CM), and in symptomatic patients who suffered from mild/moderate (group (+/++) CM, n=62) or severe cardiomyopathy (group (+++) CM, n=27). RESULTS: Both markers were higher in (+/++) CM and (+++) CM vs. (-) CM and increased in the cardiomyopathy severity. Values of 3 ng/L cTnT and 160 ng/L NT-proBNP were calculated as optimal cut-offs to distinguish (-) CM vs. CM. The NT-proBNP cut-off of 125ng/L, as recommended by international guidelines, was additionally incorporated in the analysis. Cardiomyopathy was most successfully predicted by dual positivity of both markers (positive predictive value=1.0). Negativity of both markers effectively excluded cardiomyopathy (negative predictive value of 0.85). Positivity for at least one of the markers is the best for overall correct classification. CONCLUSIONS: Combined measurement of hs-cTnT and NT-proBNP can be used for diagnosis and monitoring of cardiomyopathy in chronic Chagas' patients. In this way, laboratory medicine increases the pre-test probability of the cardiologic diagnostics, which would reduce its time, cost, and logistical problems.


Subject(s)
Chagas Cardiomyopathy/diagnosis , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Troponin T/blood , Adolescent , Adult , Aged , Aged, 80 and over , Biomarkers/blood , Chagas Cardiomyopathy/blood , Chronic Disease , Disease Progression , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Severity of Illness Index
7.
Ann Thorac Cardiovasc Surg ; 18(5): 452-7, 2012.
Article in English | MEDLINE | ID: mdl-22673555

ABSTRACT

OBJECTIVES: Chronic heart failure after myocardial infarction is still a serious problem without a fundamental therapy. Direct intramyocardial transplantation of bone marrow cells (BMC) is promising but difficult to perform. Therefore, cardiac effect of experimental intravenous application of BMC after myocardial infarction (MI) is evaluated. METHODS: 20 Lewis rats underwent suture ligation of the LAD. One month after the MI, they were randomized to receive either intravenous Lewis-BMC or saline injection. Hearts were explanted and histologically examined another month later. Transthoracic echocardiography was performed before MI and intravenous injection as well as before explantation. RESULTS: BMC transplanted animals developed less cartilaginous metaplasia (BMC-group: 30% vs Control-group: 50%, p <0.01). Moreover, systolic thickness of the interventricular septum (IVSs) increased significantly in the BMC-group only: pre-Tx 1.4 ± 0.5 mm vs post-Tx 2.3 ± 0.5 mm, p = 0.02; whereas, systolic left ventricular posterior wall diameter (LVPWD) increased in the control groups only: pre-Tx 2.6 ± 0.5 mm vs post-Tx 3.4 ± 0.8 mm, p = 0.04. BMC transplantation showed a tendency towards a smaller infarct area (BMC group, 11% vs. Control group, 13%; p = 0.07) and increases in LVEF and FS after an intravenous injection (p = 0.08). CONCLUSION: Intravenous BMC-Tx led to less calcifying remodelling and a compensatory hypertrophy within the infarction area that probably contributes to functional recovery.


Subject(s)
Bone Marrow Transplantation/methods , Heart Failure/surgery , Myocardial Infarction/surgery , Animals , Disease Models, Animal , Echocardiography , Heart Failure/diagnostic imaging , Heart Failure/etiology , Infusions, Intravenous , Myocardial Infarction/complications , Myocardial Infarction/diagnostic imaging , Random Allocation , Rats , Rats, Inbred Lew , Recovery of Function , Regeneration , Transplantation, Autologous , Treatment Outcome
8.
J Am Coll Cardiol ; 59(21): 1897-907, 2012 May 22.
Article in English | MEDLINE | ID: mdl-22595410

ABSTRACT

OBJECTIVES: This study was designed to compare the accuracy of 64-row contrast computed tomography (CT), invasive cineventriculography (CVG), 2-dimensional echocardiography (2D Echo), and 3-dimensional echocardiography (3D Echo) for left ventricular (LV) function assessment with magnetic resonance imaging (MRI). BACKGROUND: Cardiac function is an important determinant of therapy and is a major predictor for long-term survival in patients with coronary artery disease. A number of methods are available for assessment of function, but there are limited data on the comparison between these multiple methods in the same patients. METHODS: A total of 36 patients prospectively underwent 64-row CT, CVG, 2D Echo, 3D Echo, and MRI (as the reference standard). Global and regional LV wall motion and ejection fraction (EF) were measured. In addition, assessment of interobserver agreement was performed. RESULTS: For the global EF, Bland-Altman analysis showed significantly higher agreement between CT and MRI (p < 0.005, 95% confidence interval: ±14.2%) than for CVG (±20.2%) and 3D Echo (±21.2%). Only CVG (59.5 ± 13.9%, p = 0.03) significantly overestimated EF in comparison with MRI (55.6 ± 16.0%). CT showed significantly better agreement for stroke volume than 2D Echo, 3D Echo, and CVG. In comparison with MRI, CVG-but not CT-significantly overestimated the end-diastolic volume (p < 0.001), whereas 2D Echo and 3D Echo significantly underestimated the EDV (p < 0.05). There was no significant difference in diagnostic accuracy (range: 76% to 88%) for regional LV function assessment between the 4 methods when compared with MRI. Interobserver agreement for EF showed high intraclass correlation for 64-row CT, MRI, 2D Echo, and 3D Echo (intraclass correlation coefficient >0.8), whereas agreement was lower for CVG (intraclass correlation coefficient = 0.58). CONCLUSIONS: 64-row CT may be more accurate than CVG, 2D Echo, and 3D Echo in comparison with MRI as the reference standard for assessment of global LV function.


Subject(s)
Echocardiography/methods , Heart Ventricles/diagnostic imaging , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Tomography, X-Ray Computed/methods , Ventricular Function, Left , Cineradiography , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results
9.
Eur Heart J Cardiovasc Imaging ; 13(10): 863-70, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22427402

ABSTRACT

AIMS: Myocardial involvement is associated with poor prognosis in patients with systemic sclerosis (SSc). Two-dimensional speckle-tracking echocardiography (STE) is a powerful novel modality for the assessment of subclinical cardiac left ventricular (LV) dysfunction that, so far, has not been investigated in SSc patients. The aim of this study was to evaluate deformation analyses derived from STE for early detection of LV systolic dysfunction in patients with SSc having preserved left ventricular ejection fraction (LVEF). METHODS AND RESULTS: Twenty-two patients with SSc (57.1 ± 13.3 years, LVEF 64 ± 3.1%, mean time of 5.4 ± 4.6 years from diagnosis) and 22 gender- and age-matched healthy subjects (57.4 ± 14.0 years, LVEF 65 ± 2.7%) underwent echocardiography with STE to assess global and regional LV function. The global longitudinal 2D peak systolic strain (PSS) of the left ventricle was significantly lower in the SSc group compared with controls: -19.0 ± 2.4 vs. -21.1 ± 2.5% (P = 0.008). This was mainly driven by a reduced strain in the basal segments. Strain in the medial segments and in the apex did not differ significantly. In addition, there was a significant difference between both groups regarding the global longitudinal PSS rate of the left ventricle (-1.19 ± 0.18 vs. -1.43 ± 0.26 s(-1), P = 0.001). CONCLUSION: LV deformation analysis by STE is a sensitive method to detect early LV systolic impairment primarily in the basal segments in patients with SSc having preserved LVEF.


Subject(s)
Echocardiography , Heart Ventricles/diagnostic imaging , Myocardium/pathology , Scleroderma, Systemic/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Adult , Aged , Female , Heart Ventricles/pathology , Humans , Male , Middle Aged , Scleroderma, Systemic/complications , Scleroderma, Systemic/pathology , Statistics, Nonparametric , Time Factors , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/pathology
10.
Cardiovasc Ultrasound ; 10: 15, 2012 Mar 26.
Article in English | MEDLINE | ID: mdl-22448716

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a promising therapy for patients with severe aortic stenosis (AS) and high perioperative risk. New echocardiographic methods, including 2D Strain analysis, allow the more accurate measurement of left ventricular (LV) systolic function. The goal of this study was to describe the course of LV reverse remodelling immediately after TAVI in a broad spectrum of patients with symptomatic severe aortic valve stenosis. METHODS: Thirty consecutive patients with symptomatic aortic valve stenosis and preserved LVEF underwent transfemoral aortic valve implantation. We performed echocardiography at baseline and one week after TAVI. Echocardiography included standard 2D and Doppler analysis of global systolic and diastolic function as well as 2D Strain measurements of longitudinal, radial and circumferential LV motion and Tissue Doppler echocardiography. RESULTS: The baseline biplane LVEF was 57 ± 8.2%, the mean pressure gradient was 46.8 ± 17.2 mmHg and the mean valve area was 0.73 ± 0.27 cm(2). The average global longitudinal 2D strain of the left ventricle improved significantly from -15.1 (± 3.0) to -17.5 (± 2.4) % (p < .001). This was reflected mainly in improvement in the basal and medial segments while strain in the apex did not change significantly [-11.6 (± 5.2) % to -15.1 (± 5.5) % (p < .001), -13.9 (± 5.1) % to -16.8 (± 5.6) % (p < .001) and -19.2 (± 7.0) % to -20.0 (± 7.2) % (p = .481) respectively]. While circumferential strain [-18.1 (± 5.1) % vs. -18.9 (± 4.2) %, p = .607], radial strain [36.5 (± 13.7) % vs. 39.7 (± 17.2) %, p = .458] and the LVEF remained unchanged after one week [57.0 (± 8.2) % vs. 59.1 (± 8.1) %, p = .116]. CONCLUSION: There is an acute improvement of myocardial longitudinal systolic function of the basal and medial segments measured by 2D Strain analysis immediately after TAVI. The radial, circumferential strain and LVEF does not change significantly in all patients acutely after TAVI. These data suggest that sensitive new echo methods can reliably detect early regional changes of myocardial function after TAVI before benefits in LVEF are detectable.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography/methods , Heart Valve Prosthesis , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/surgery , Aged , Aged, 80 and over , Aortic Valve Stenosis/complications , Elasticity Imaging Techniques , Female , Humans , Male , Recovery of Function , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome , Ventricular Dysfunction, Left/etiology
11.
Cardiovasc Ultrasound ; 10: 6, 2012 Feb 22.
Article in English | MEDLINE | ID: mdl-22357096

ABSTRACT

BACKGROUND: Our study compares new single beat 3D echocardiography (sb3DE) to cardiovascular magnetic resonance imaging (CMR) for the measurement of right ventricular (RV) dimension and function immediately after a 30 km run. This is to validate sb3DE against the "gold standard" CMR and to bring new insights into acute changes of RV dimension and function after endurance exercise. METHODS: 21 non-elite male marathon runners were examined by sb3DE (Siemens ACUSON SC2000, matrix transducer 4Z1c, volume rates 10-29/s), CMR (Siemens Magnetom Avanto, 1,5 Tesla) and blood tests before and immediately after each athlete ran 30 km. The runners were not allowed to rehydrate after the race. The order of sb3DE and CMR examination was randomized. RESULTS: Sb3DE for the acquisition of RV dimension and function was feasible in all subjects. The decrease in mean body weight and the significant increase in hematocrit indicated dehydration. RV dimensions measured by CMR were consistently larger than measured by sb3DE.Neither sb3DE nor CMR showed a significant difference in the RV ejection fraction before and after exercise. CMR demonstrated a significant decrease in RV dimensions. Measured by sb3DE, this decrease of RV volumes was not significant. CONCLUSION: First, both methods agree well in the acquisition of systolic RV function. The dimensions of the RV measured by CMR are larger than measured by sb3DE. After exercise, the RV volumes decrease significantly when measured by CMR compared to baseline.Second, endurance exercise seems not to induce acute RV dysfunction in athletes without rehydration.


Subject(s)
Echocardiography, Three-Dimensional , Heart Ventricles/diagnostic imaging , Magnetic Resonance Imaging , Ventricular Function, Right , Feasibility Studies , Humans , Male , Physical Endurance/physiology , Running/physiology
12.
Cardiovasc Ultrasound ; 9: 15, 2011 May 26.
Article in English | MEDLINE | ID: mdl-21615917

ABSTRACT

OBJECTIVES: Feasibility of noninvasive monitoring of cardiac function after surgically induced ischemic cardiomyopathy with tissue Doppler and non-Doppler 2D strain echocardiography in rats. BACKGROUND: The optimal method for quantitative assessment of global and regional ventricular function in rats with chronic heart failure for research purposes remains unclear. METHODS: 20 rats underwent suture ligation of the left anterior descending coronary artery via a left thoracotomy to induce ischemic cardiomyopathy. Echocardiographic examination with estimation of left ventricular wall thickness, diameters, fractional shortening, ejection fraction, wall velocities as well as radial strain were performed before and 4 weeks after surgery. RESULTS: Mean LVEF decreased from 70 ± 6% to 40 ± 8% (p < 0.0001) one month after the operation. LVEDD increased from 7 ± 1 mm to 9 ± 1 mm (p < 0.0001), systolic anterior velocity decreased from 0.79 ± 0.25 cm/s to 0.18 ± 0.19 cm/s (p < 0.0001). Radial 2D strain was significantly reduced after myocardial infarction of the septal (18.2 ± 6.6% vs 7.0 ± 5.9%, p < 0.001), anteroseptal (17.3 ± 5.2% vs 4.6 ± 3.0%, p < 0.0001), anterior (18.9 ± 5.9% vs 5.6 ± 2.5%, p < 0.0001), lateral (21.4 ± 4.9% vs 8.1 ± 3.5%, p < 0.0001) as well as posterior myocardial segments (19.3 ± 5.2% vs 15.4 ± 5.5%, p < 0.01). Inferior segments (19.2 ± 7.9% vs 17.8 ± 7.9%, ns) did not change at all. CONCLUSION: It is feasible to assess dimensions, global function, and regional contractility with echocardiography in rats suffering from chronic heart failure after myocardial infarction. Particularly regional function can be exactly evaluated if tissue Doppler and 2D strain is used.


Subject(s)
Echocardiography, Doppler, Color/methods , Echocardiography, Doppler/methods , Heart Failure/diagnostic imaging , Myocardial Ischemia/diagnostic imaging , Animals , Chronic Disease , Disease Models, Animal , Feasibility Studies , Female , Male , Monitoring, Physiologic/methods , Myocardial Infarction/diagnostic imaging , Normal Distribution , Random Allocation , Rats , Rats, Inbred Lew , Statistics, Nonparametric , Stroke Volume
13.
Arch Pathol Lab Med ; 135(2): 243-8, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21284445

ABSTRACT

CONTEXT: Chronic Chagas disease (15 million patients; annual incidence, 40, 000 patients; annual mortality, 12 ,500 patients) is the most serious parasitic disease in Latin America. Between 10 and 30 years after infection, 30% of patients with Chagas disease develop heart injury, which is the main reason for its high mortality. Consequently, frequent cardiac diagnostics are required for patients with Chagas disease. OBJECTIVE: To minimize time-intensive and cost-intensive diagnostics, such as electrocardiography, echocardiography, and radiologic imaging, we tested the effect of measuring serum cardiac troponin T (cTnT) with a highly sensitive assay. To indicate the pathophysiologic background for cTnT release in Chagas heart injury, inflammation markers, such as C-reactive protein and interleukin 6, were measured in parallel. DESIGN: Serum cTnT was measured in 26 healthy subjects and in 179 patients with chronic Chagas disease who were asymptomatic (indeterminate stage, n  =  86), who were suffering from cardiomyopathy with or without megacolon (n  =  71), or who were suffering from megacolon exclusively (n  =  22). RESULTS: Serum cTnT was significantly higher in patients with cardiomyopathy with or without megacolon than in healthy subjects, asymptomatic subjects, and patients with megacolon, and the cTnT value was correlated with the severity of the cardiomyopathy. The lower limit of detection for the highly sensitive assay (3 ng/L) was best at distinguishing patients with, and without, heart injury. C-reactive protein and interleukin 6 were found to parallel cTnT changes in both the different Chagas groups and the cardiomyopathy groups separated by disease severity. CONCLUSIONS: Highly sensitive cTnT measurement has the potential to contribute to diagnosis and monitoring of heart injury in patients with chronic Chagas disease. The highly sensitive assay of cTnT release seems to be related to Chagas heart disease-specific inflammation.


Subject(s)
Blood Chemical Analysis/methods , Chagas Cardiomyopathy/blood , Chagas Cardiomyopathy/diagnosis , Troponin T/blood , Adult , Aged , Aged, 80 and over , Chagas Disease/blood , Chagas Disease/complications , Chagas Disease/diagnosis , Chronic Disease , Female , Humans , Male , Megacolon/blood , Megacolon/etiology , Middle Aged , Myocardium/metabolism , Retrospective Studies , Sensitivity and Specificity , Young Adult
14.
Eur J Radiol ; 77(3): 426-35, 2011 Mar.
Article in English | MEDLINE | ID: mdl-19783394

ABSTRACT

OBJECTIVE: We sought to determine the comparability of multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) for measuring the aortic valve orifice area (AVA) and grading aortic valve stenosis. MATERIALS AND METHODS: Twenty-seven individuals, among them 18 patients with valvular stenosis, underwent AVA planimetry by both MSCT and MRI. In the subset of patients with valvular stenosis, AVA was also calculated from transthoracic Doppler echocardiography (TTE) using the continuity equation. RESULTS: There was excellent correlation between MSCT and MRI (r = 0.99) and limits of agreement were in an acceptable range (± 0.42 cm(2)) although MSCT yielded a slightly smaller mean AVA than MRI (1.57 ± 0.83 cm(2) vs. 1.67 ± 0.98 cm(2), p < 0.05). However, in the subset of patients with valvular stenosis, the mean AVA was not different between MSCT and MRI (1.05 ± 0.30 cm(2) vs. 1.04 ± 0.39 cm(2); p > 0.05). The mean AVAs on both MSCT and MRI were systematically larger than on TTE (0.88 ± 0.28 cm(2), p < 0.001 each). Using an AVA of 1.0 cm(2) on TTE as reference, the best threshold for detecting severe-to-critical stenosis on MSCT and MRI was an AVA of 1.25 cm(2) and 1.30 cm(2), respectively, resulting in an accuracy of 96% each. CONCLUSION: Our study specifies recent reports on the suitability of MSCT for quantifying AVA. The data presented here suggest that certain methodical discrepancies of AVA measurements exist between MSCT, MRI and TTE. However, MSCT and MRI have shown excellent correlation in AVA planimetry and similar accuracy in grading aortic valve stenosis.


Subject(s)
Anatomy, Cross-Sectional/methods , Aortic Valve Stenosis/diagnosis , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Magnetic Resonance Imaging/methods , Tomography, Spiral Computed/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
15.
Cardiovasc Ultrasound ; 8: 35, 2010 Sep 01.
Article in English | MEDLINE | ID: mdl-20809960

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) is generally associated with a low to moderate increase of the left ventricular ejection fraction (LVEF). In some patients, however, LVEF improves remarkably and reaches near-normal values. The aim of the present study was to further characterize these so called 'super-responders' with a special focus on the extent of intra- and interventricular asynchrony before and after device implantation compared to average responders. METHODS: 37 consecutive patients who underwent CRT device implantation according to current guidelines were included in the study. Patients were examined by echocardiography before, one day after and six months after device implantation. Pre-defined criterion for superior response to CRT was an LVEF increase > 15% after six months. RESULTS: At follow-up, eight patients (21.6%) were identified as super-responders. There were no significant differences regarding age, gender, prevalence of ischemic heart disease and LVEF between average and super-responders at baseline. After six months, LVEF had significantly increased from 26.7% ± 5.7% to 33.1% ± 7.9% (p < 0.001) in average and from 24.0% ± 6.7% to 50.3% ± 7.4% (p < 0.001) in super-responders. Both groups showed a significant reduction of QRS duration as well as LV end-diastolic and -systolic volumes under CRT. At baseline, the interventricular mechanical delay (IVMD) was 53.7 ± 20.9 ms in average and 56.9 ± 22.4 ms in super-responders - representing a similar extent of interventricular asynchrony in both groups (p = 0.713). CRT significantly reduced the IVMD to 20.3 ± 15.7 (p < 0.001) in average and to 19.8 ± 15.9 ms (p = 0.013) in super-responders with no difference between both groups (p = 0.858). As a marker for intraventricular asynchrony, we assessed the longest intraventricular delay between six basal LV segments. At baseline, there was no difference between average (86.2 ± 30.5 ms) and super-responders (78.8 ± 23.6 ms, p = 0.528). CRT significantly reduced the longest intraventricular delay in both groups--with a significant difference between average (66.2 ± 36.2 ms) and super-responders (32.5 ± 18.3 ms, p = 0.022). Multivariate logistic regression analysis identified the longest intraventricular delay one day after device implantation as an independent predictor of superior response to CRT (p = 0.038). CONCLUSIONS: A significant reduction of the longest intraventricular delay correlates with superior response to CRT.


Subject(s)
Cardiac Resynchronization Therapy/methods , Heart Conduction System/physiopathology , Heart Failure/therapy , Heart Ventricles/physiopathology , Ventricular Remodeling/physiology , Aged , Echocardiography , Electrocardiography , Female , Follow-Up Studies , Heart Conduction System/diagnostic imaging , Heart Failure/diagnostic imaging , Heart Failure/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/innervation , Humans , Male , Retrospective Studies , Stroke Volume/physiology , Treatment Outcome
16.
Cardiovasc Ultrasound ; 8: 18, 2010 May 16.
Article in English | MEDLINE | ID: mdl-20470437

ABSTRACT

Acute pulmonary embolism (PE) is a common disease which frequently results in life-threatening right ventricular (RV) failure. High-risk PE, presenting with hypotension, shock, RV dysfunction or right heart thrombus is associated with a high mortality, particularly during the first few hours. Accordingly, it is important to commence effective therapy as soon as possible. In the case described in this report, a 49-year-old woman with myotonic dystrophy type 1 presented with acute respiratory failure and hypotension. Transthoracic echocardiography showed signs of right heart failure and a mobile right heart mass highly suspicious of a thrombus. Based on echocardiographic findings, acute thrombolysis was performed resulting in hemodynamic stabilization of the patient and complete resolution of the right heart thrombus. This case underscores the important role of transthoracic echocardiography for the diagnosis, management and monitoring of PE and underlines the efficacy and safety of thrombolysis in the treatment of PE associated with right heart thrombus.


Subject(s)
Echocardiography , Heart Diseases/diagnostic imaging , Myotonic Dystrophy/complications , Pulmonary Embolism/diagnostic imaging , Thrombolytic Therapy , Thrombosis/diagnostic imaging , Female , Heart Diseases/complications , Heart Diseases/drug therapy , Humans , Middle Aged , Pulmonary Embolism/complications , Pulmonary Embolism/drug therapy , Thrombosis/complications , Thrombosis/drug therapy
17.
Clin Lab ; 56(1-2): 51-8, 2010.
Article in English | MEDLINE | ID: mdl-20380359

ABSTRACT

BACKGROUND: As shown on the basis of highly sensitive assays, cardiac troponin release is now observed after physiological heart stress and in mild heart pathologies: both are [corrected] considered unrelated to the irreversible cardiac alteration that is typically the source of release. Transitory cardiac membrane leakage was suggested as the basis. In our view, mild inflammation may drive this type of cardiac troponin release. To verify this hypothesis, marathon runners who demonstrated post-run inflammation were used as a model to correlate cTnT release and inflammation intensity. METHODS: In 78 male marathon runners who participated in the BERLIN-MARATHON 2006, cardiac troponin T (cTnT) was monitored [corrected] at three time points (pre-race, post-race, and after two weeks of rest). [corrected] Measurements were done with the highly sensitive assay (hs cTnT assay) and the conventional fourth-generation cTnT assay for comparison. Concurrently, [corrected] the inflammation markers (leukocyte and neutrophil counts, CRP, IL-6) were measured. RESULTS: Pre-race, the fourth-generation assay failed to demonstrate cTnT positivity (> test specific LLD). In contrast, with the [corrected] use of the highly sensitive assay, 28% of the participants were positive for cTnT (> LLD of hs cTnT assay). Post-race, cTnT as measured with the fourth-generation assay was observed to be detectable in 43% of the runners (> LLD = 99(th) percentile cut off), but all runners had detectable cTnT values (> LLD) when measured with the highly sensitive assay. Even in 94% of these cTnT-positive runners, the value exceeded the 99(th) percentile cut off determined for the highly sensitive assay (13 ng/L). cTnT release correlated significantly with inflammation intensity. Faster runners demonstrated significantly stronger cTnT releases and inflammation signs. CONCLUSIONS: As demonstrated after physiological heart stress such as marathon running, transitory inflammation is evidently one of the events contributing to the cardiac troponin release under conditions suggested as unrelated to irreversible cardiac alteration.


Subject(s)
Athletic Injuries/blood , Inflammation/etiology , Running/physiology , Troponin T/blood , Asthma/blood , Asthma/epidemiology , Athletes , Blood Pressure , Heart Rate , Humans , Hypertension/blood , Hypertension/epidemiology , Inflammation/blood , Male , Sensitivity and Specificity
18.
Cardiovasc Ultrasound ; 8: 3, 2010 Jan 22.
Article in English | MEDLINE | ID: mdl-20096122

ABSTRACT

BACKGROUND: Isovolumetric acceleration (IVA) is a novel tissue Doppler parameter for the assessment of systolic function. The aim of this study was to evaluate IVA as an early parameter for the detection of right ventricular (RV) systolic dysfunction in patients with systemic sclerosis (SSc) without pulmonary hypertension. METHODS: 22 patients and 22 gender- and age-matched healthy subjects underwent standard echocardiography with tissue Doppler imaging (TDI) and speckle tracking strain to assess RV function. RESULTS: Tricuspid annular plane systolic excursion (TAPSE) (23.2 +/- 4.1 mm vs. 26.5 +/- 2.9 mm, p < 0.006), peak myocardial systolic velocity (Sm) (11.6 +/- 2.3 cm/s vs. 13.9 +/- 2.7 cm/s, p = 0.005), isovolumetric contraction velocity (IVV) (10.3 +/- 3 cm/s vs. 14.8 +/- 3 cm/s, p < 0.001) and IVA (2.3 +/- 0.4 m/s2 vs. 4.1 +/- 0.8 m/s2, p < 0.001) were significant lower in the patient group. IVA was the best parameter to predict early systolic dysfunction with an area under the curve of 0.988. CONCLUSION: IVA is a useful tool with high-predictive power to detect early right ventricular systolic impairment in patients with SSc and without pulmonary hypertension.


Subject(s)
Echocardiography, Doppler/methods , Echocardiography, Doppler/standards , Scleroderma, Systemic/complications , Ventricular Dysfunction, Right/diagnostic imaging , Adult , Aged , Early Diagnosis , Echocardiography, Doppler/statistics & numerical data , Female , Humans , Hypertension, Pulmonary , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Pulsatile Flow , Respiratory Function Tests , Stroke Volume , Systole , Ventricular Dysfunction, Right/complications , Ventricular Function, Right
19.
Int J Cardiol ; 143(2): 211-3, 2010 Aug 20.
Article in English | MEDLINE | ID: mdl-19144427

ABSTRACT

We assessed the hypothesis that non-invasive measurement of stroke volume index can replace invasive measurements in patients with chronic heart failure. Non-invasive impedance cardiography (ICG) measurements together with invasive hemodynamic thermodilution (TD) measurements were performed in 13 patients with severe chronic heart failure (NYHA III-IV). Agreement between ICG and TD regarding stroke volume index was poor. Correlation between non-invasive and invasive hemodynamic measurements was low (r=0.29). In conclusion, non-invasive measurements of stroke volume index using impedance cardiography did not result in sufficient agreement with invasive thermodilution measurements in this study with patients suffering from severe chronic heart failure.


Subject(s)
Cardiac Catheterization , Cardiography, Impedance , Heart Failure/diagnosis , Heart Failure/physiopathology , Stroke Volume , Adult , Aged , Chronic Disease , Female , Humans , Male , Middle Aged , Thermodilution
20.
Cardiovasc Ultrasound ; 7: 46, 2009 Sep 25.
Article in English | MEDLINE | ID: mdl-19781060

ABSTRACT

BACKGROUND: Established methods to determine asynchrony suffer from high intra- and interobserver variability and failed to improve patient selection for cardiac resynchronization therapy (CRT). Thus, there is a need for easy and robust approaches to reliably assess cardiac asynchrony. METHODS AND RESULTS: We performed echocardiography in 100 healthy subjects and 33 patients with left bundle branch block (LBBB). To detect intraventricular asynchrony, we combined two established methods, i.e., tissue synchronization imaging (TSI) and tissue Doppler imaging (TDI). The time intervals from the onset of aortic valve opening (AVO) to the peak systolic velocity (S') were measured separately in six basal segments in the apical four-, two-, and three-chamber view. Color-coded TSI served as an intrinsic plausibility control and helped to identify the correct S' measuring point in the TDI curves. Next, we identified the segment with the shortest AVO-S' interval. Since this segment most likely represents vital and intact myocardium it served as a reference for other segments. Segments were considered asynchronous when the delay between the segment in question and the reference segment was above the upper limit of normal delays derived from the control population. Intra- and interobserver variability were 7.0% and 7.7%, respectively. CONCLUSION: Our results suggest that combination of TDI and TSI with intrinsic plausibility control improves intra- and interobserver variability and allows easy and reliable assessment of cardiac asynchrony.


Subject(s)
Bundle-Branch Block/complications , Bundle-Branch Block/diagnostic imaging , Echocardiography/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Algorithms , Feasibility Studies , Female , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...